1kVDC Isolated 3W Single Output DC-DC Converters KDC_MEE3.B01 Page 1 of 8 www.murata-ps.com www.murata.com For full details go to www.murata-ps.com/rohs SELECTION GUIDE Order Code Nominal Input Voltage Output Voltage Output Current Input Current at Rated Load Load Regulation (Typ) Load Regulation (Max) Ripple & Noise (Typ)1 Ripple & Noise (Max)1 Efficiency (Min.) Efficiency (Typ.) Isolation Capacitance MTTF2 V V mA mA % mVp-p % % pF MHrs MEE3S0505SC 5 5 600 703 6.3 8 46 70 80 83 32 3.9 MEE3S0509SC 5 9 333 677 5.2 6.5 28 45 84 87 50 2.9 MEE3S0512SC 5 12 250 691 4.7 6 26 45 83 86 41 4.2 MEE3S0515SC 5 15 200 679 4.7 6.5 24 45 85 88 51 2.5 MEE3S1205SC 12 5 600 290 4.3 6 41 60 82 85 42 3.6 MEE3S1209SC 12 9 333 280 3.5 5 21 40 84 88 66 3.7 MEE3S1212SC 12 12 250 280 3 4.5 19 40 84 88 77 3.4 MEE3S1215SC 12 15 200 277 2.7 4 21 40 85 89 91 3.4 INPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Voltage range Continuous operation, 5V input types 4.5 5 5.5 VContinuous operation, 12V input types 10.8 12 13.2 Reflected ripple current 5V input types 5 15 mA p-p12V input types 5 15 OUTPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Rated Power TA=-40°C to 85°C 3W Voltage Set Point Accuracy See tolerance envelope Line regulation High V IN to low VIN 1.01 1.1 %/% ISOLATION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Isolation test voltage Flash tested for 1 second 1000 VDC Resistance Viso= 1000VDC 10 GΩ GENERAL CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Switching frequency 60 kHz TEMPERATURE CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Specification All output types, See safety approval section for UL temperature specification -40 85 °CStorage -50 125 Case Temperature rise above ambient MEE3Sxx05SC, MEE3S0512C 40 MEE3S0515C, MEE3S1209C, MEE3S1212C 35 MEE3S1215C, MEE3S0509C 30 Cooling Free air convection PRODUCT OVERVIEW The MEE3 series is a new range of high performance 3W DC-DC converters, offering 3W of available output power in a previously rated 2W package capable of operation over the full industrial temperature range of -40ºC to 85ºC Available in an industry standard SIP package, with a pin compatible power upgrade path from the 1W NME/NKE and 2W NML series’, they are ideally suited for providing local supplies on control system boards with the added benefit of 1kVDC galvanic isolation.
FEATURES
UL60950 recognised RoHS compliant Typical efficiency from 83% Power density 2.68W/cm3 Wide temperature performance at full
3 Watt load, –40°C to 85°C
UL 94V-0 package material No heatsink required Industry standard pinout 5V & 12V inputs 5V, 9V, 12V & 15V outputs Fully encapsulated with toroidal magnetics No external components required No electrolytic or tantalum capacitors 1. See Ripple & Noise characterisation method. 2. Calculated using MIL-HDBK-217F FN2 with nominal input voltage at full load. 3. See safety approval section on page 2. All specifications typical at T A=25°C, nominal input voltage and rated output current unless otherwise specified.
1kVDC Isolated 3W Single Output DC-DC Converters KDC_MEE3.B01 Page 2 of 8 www.murata.com ABSOLUTE MAXIMUM RATINGS Lead temperature 1mm from case for 10 seconds 260°C Wave Solder Wave Solder profile not to exceed the profile recommended in IEC 61760-1 Section 6.1.3. Please refer to application notes for further information. Input voltage VIN, MEE3S05 types 7V Input voltage VIN, MEE3S12 types 15V
1kVDC Isolated 3W Single Output DC-DC Converters KDC_MEE3.B01 Page 3 of 8 www.murata.com TECHNICAL NOTES ISOLATION VOLTAGE ‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Murata Power Solutions MEE3 series of DC-DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second. A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?” The MEE3 series has been recognised by Underwriters Laboratory for functional isolation. Both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety standard requirements. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materi- als, construction and environment. The MEE3 series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enamelled wire. While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage. This consideration equally applies to agency recognised parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further insulation system of physical spacing or barriers. SAFETY APPROVAL The MEE3 series has been recognised by Underwriters Laboratory (UL) to UL 60950 for functional isolation in a maximum still air ambient temperature of 63°C and/or case tempera- ture limit of 91°C. Case temperature measured on the face opposite the pins. File number E151252 applies. The MEE3 series of converters are not internally fused so to meet the requirement of UL 60950, an input line fuse should always be used. An anti-surge 2.5A should be used for MEE3S05XXSC models, and an anti-surge 1A should be used for MEE3S12xxSC models. All fuses should be UL approved and rated to at least the maximum allowable DC input voltage. RoHS COMPLIANT INFORMATION This series is compatible with RoHS soldering systems with a peak wave solder temperature of 260°C for 10 seconds. Please refer to application notes for further information. The pin termination finish is Tin Plate, Hot Dipped over Matte Tin with Nickel Preplate. They are backward compatible with Sn/Pb soldering systems. For further information, please visit www.murata-ps.com/rohs PART NUMBER STRUCTURE MEE 3 S XX XX S C Series name Power rating Output type S - Single D - Dual RoHS compliant Package type S - SIP D - DIP M - Surface mount Z - ZIP Output voltageInput voltage
1kVDC Isolated 3W Single Output DC-DC Converters KDC_MEE3.B01 Page 4 of 8 www.murata.com APPLICATION NOTES Output Ripple Reduction By using the values of inductance and capacitance stated, the output ripple at the rated load is lowered to 5mV p-p max. Component selection Capacitor: It is required that the ESR (Equivalent Series Resistance) should be as low as possible, ceramic types are recommended. The voltage rating should be at least twice (except for 15V output), the rated output voltage of the DC-DC converter. Inductor: The rated current of the inductor should not be less than that of the output of the DC-DC converter. At the rated current, the DC resistance of the inductor should be such that the voltage drop across the inductor is <2% of the rated voltage of the DC-DC converter. The SRF (Self Resonant Frequency) should be >20MHz. DC DC L C LoadPower Source Inductor Capacitor L, μH SMD Through Hole C, μF MEE3S0505SC 10 84103C 11R103C 4.7 MEE3S0509SC 22 84223C 11R223C 2.2 MEE3S0512SC 47 84473C 11R473C 1 MEE3S0515SC 47 84473C 11R473C 1 MEE3S1205SC 10 84103C 11R103C 4.7 MEE3S1209SC 22 84223C 11R223C 2.2 MEE3S1212SC 47 84473C 11R473C 1 MEE3S1215SC 47 84473C 11R473C 1 CHARACTERISATION TEST METHODS Ripple & Noise Characterisation Method Ripple and noise measurements are performed with the following test configuration. C1 1μF X7R m ultilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC-DC converter C2 10μF tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC-DC converter with an ESR of less than 100mΩ at 100 kHz C3 100nF multilayer ceramic capacitor, general purpose R1 450Ω resistor, carbon film, ±1% tolerance R2 50Ω BNC termination T1 3T of the coax cable through a ferrite toroid RLOAD Resistive load to the maximum power rating of the DC-DC converter. Connections should be made via twisted wires Measured values are multiplied by 10 to obtain the specified values. Differential Mode Noise Test Schematic OSCILLOSCOPE Y INPUT SUPPLY C1 C2 C3 R1 T1 R2 Input Output DC/DC Converter R LOAD + + - -
1kVDC Isolated 3W Single Output DC-DC Converters KDC_MEE3.B01 Page 5 of 8 www.murata.com APPLICATION NOTES (Continued) Minimum Load The minimum load to meet datasheet specification is 10% of the full rated load across the specified input voltage range. Lower than 10% minimum loading will result in an increase in output voltage, which may rise to typically 1.25 times the specified output voltage if the output load falls to less than 5%. Capacitive Loading & Start Up Typical start up times for this series, with a typical input voltage rise time of 2.2μs with resistive only load, and with added output capacitance of 47μF, are shown in the table below Start-Up Time Part Number μS MEE3S0505SC 490 MEE3S0509SC 1130 MEE3S0512SC 2070 MEE3S0515SC 3515 MEE3S1205SC 415 MEE3S1209SC 715 MEE3S1212SC 1100 MEE3S1215SC 1430 Typical Start-Up Wave Form
1kVDC Isolated 3W Single Output DC-DC Converters KDC_MEE3.B01 Page 6 of 8 www.murata.com TEMPERATURE DERATING GRAPH EFFICIENCY VS LOAD MEE3S05XXSC MEE3S12XXSC 100 0 1 02 03 04 05 06 07 08 09 0 1 0 0 Load (%) Efficiency (%) 15V 12V 100 0 1 02 03 04 05 06 07 08 09 0 1 0 0 Load (%) Efficiency (%) 15V 12V TOLERANCE ENVELOPES The voltage tolerance envelope shows typical load regulation characteristics for this product series. The tolerance envelope is the maximum output voltage variation due to changes in output loading. All variants Output Load Current (%) Output Voltage -4% 100755025 10 Typical Load Line 150100500-40 1.5 3.0 4.5 Safe Operating Area 85°C Ambient Temperature (°C) Output Power (W)
1kVDC Isolated 3W Single Output DC-DC Converters KDC_MEE3.B01 Page 7 of 8 www.murata.com PACKAGE SPECIFICATIONS MECHANICAL DIMENSIONS PIN CONNECTIONS - 4 PIN SIP Pin Function 1- V IN 2+ V IN 3- V OUT 4+ V OUT TUBE OUTLINE DIMENSIONS RECOMMENDED FOOTPRINT DETAILS 14.15 (0.557) Max. 8.15 (0.321) Max. 10.15 (0.400) Max. 4.1±0.5 (0.16±0.020) 0.25 (0.100) 0.4 (0.016) Min. 3.16 (0.124) 3.87 (0.152) 7.62 (0.300) 1.00-1.45 (0.039-0.057) 0.55 (0.022) 0.45 (0.018) 1234 XYYWW MEE3XXXXSC and within ± 0.25 (0.01) of true position. Weight: 2.3 g 2.54 (0.1) 2.54 (0.1) 1.15 (0.0453) 1.00 (0.0394)Ø 0.1 (0.00394)
4 HOLES
Tube Quantity: 35 Unless otherwise stated all dimensions in mm (inches) ±0.5mm. 17.00 (0.669) 11.43 (0.45) 4.00 (0.157) 9.05 (0.356) 0.50±0.15 (0.197±0.006) Unless otherwise stated all dimensions in mm (inches) ±0.5mm. Tube length: 520mm ±2mm (20.47).
1kVDC Isolated 3W Single Output DC-DC Converters KDC_MEE3.B01 Page 8 of 8 www.murata.com Murata Power Solutions (Milton Keynes) Ltd. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2021 Murata Power Solutions (Milton Keynes) Ltd. This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: https://www.murata.com/en-eu/products/power/requirements DISCLAIMER Unless otherwise stated in the datasheet, all products are designed for standard commercial and industrial applications and NOT for safety-critical and/or life-critical applications. Particularly for safety-critical and/or life-critical applications, i.e. applications that may directly endanger or cause the loss of life, inflict bodily harm and/or loss or severe damage to equipment/property, and severely harm the environment, a prior explicit written approval from Murata is strictly required. Any use of Murata standard prod- ucts for any safety-critical, life-critical or any related applications without any prior explicit written approval from Murata shall be deemed unauthorised use. These applications include but are not limited to:
- Aircraft equipment
- Aerospace equipment
- Undersea equipment
- Power plant control equipment
- Medical equipment
- Transportation equipment ( automobiles, trains, ships, etc.)
- Traffic signal equipment
- Disaster prevention / crime prevention equipment
- Data Processing equipment Murata makes no express or implied warranty, representation, or guarantee of suitability, fitness for any particular use/purpose and/or compatibility with any applica- tion or device of the buyer, nor does Murata assume any liability whatsoever arising out of unauthorised use of any Murata product for the application of the buyer. The suitability, fitness for any particular use/purpose and/or compatibility of Murata product with any application or device of the buyer remain to be the responsibility and liability of the buyer. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards that anticipate dangerous consequences of failures, moni- tor failures and their consequences, lessen the likelihood of failures that might cause harm, and take appropriate remedial actions. Buyer will fully indemnify and hold Murata, its affiliated companies, and its representatives harmless against any damages arising out of unauthorised use of any Murata products in any safety-critical and/ or life-critical applications. Remark: Murata in this section refers to Murata Manufacturing Company and its affiliated companies worldwide including, but not limited to, Murata Power Solutions.