- SIP SSR
- Ratings to 5A @ 280 VAC
- SCR output for heavy industrial loads
- AC or DC control
- Zero-crossing (resistive loads) or random-fire (inductive loads) output
- Plastic encapsulated PRODUCT SELECTION Control Voltage 5A 5A 5A 3-15 VDC MCX240D5 4-15 VDC MCX380D5 MCX480D5 15-32 VDC MCXE240D5 MCXE380D5 MCXE480D5 18-36 VAC MCXE240A5 90-140 VAC MCX240A5 AVAILABLE OPTIONS OUTPUT SPECIFICATIONS (1)
Description
Operating Voltage (47-63Hz) [Vrms] 12-280 48-530 48-660 Transient Overvoltage [Vpk] 600 1200 1200 Maximum Off-State Leakage Current @ Rated Voltage [mArms] 0.1 0.1 0.1 Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (2) 500 500 500 Maximum Load Current Arms 5 5 5 Minimum Load Current [Arms] 0.06 0.06 0.06 Maximum Surge Current (16.6ms) [Apk] 250 250 250 Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.4 1.4 1.4 Maximum I²t for fusing (8.3 msec) [A²sec] 260 260 260 Minimum Power Factor (with Maximum Load) 0.5 0.5 0.5 For Contact information visit our web site. www.crydom.com ©2008 Crydom, Inc. Specifications subject to change without notice.
INPUT SPECIFICATIONS (1) Description MCX240Dx MCX380Dx MCXExxxDx MCX240A5 MCXE240A5 Control Voltage Range 3-15 VDC 4-15 VDC 15-32 VDC 90-140 VAC 18-36 VAC Input Current @ Nominal Voltage 15 mAdc 15 mAdc 15 mAdc 10 mAdc 10 mAdc Nominal Input Impedance 300 Ohm 240 Ohm 1500 Ohm 14.1 Ohm 2.1 k Ohm Maximum Turn-On Time [msec] (3) 1/2 Cycle 1/2 Cycle 1/2 Cycle 10 10 Maximum Turn-Off Time [msec] 1/2 Cycle 1/2 Cycle 1/2 Cycle 40 40 GENERAL SPECIFICATIONS Description Parameters Dielectric Strength, Input/Output/Base (50/60Hz) 4000 Vrms Minimum Insulation Resistance (@ 500 VDC) 10 9 Ohm Maximum Capacitance, Input/Output 10pF Ambient Operating Temperature Range -40 to 80 °C Ambient Storage Temperature Range -40 to 125 °C Weight (typical) 0.7 oz. (20g) Encapsulation Therminally Conductive Epoxy GENERAL NOTES 1) All parameters at 25°C unless otherwise specified. 2) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 ) Turn-On time for random turn-on versions is 0.01 msec (DC Control Models ). MECHANICAL SPECIFICATIONS DC CONTROL. PIN 1: AC LOAD PIN 2: AC LOAD PIN 3: +DC CONTROL PIN 4: -DC CONTROL AC CONTROL. PIN 1: AC LOAD PIN 2: AC LOAD PIN 3: AC CO NTRO L PIN 4: AC CONTROL AGENCY APPROVALS UL E116949 Rev. 061608 For Contact information visit our web site. www.crydom.com ©2008 Crydom, Inc. Specifications subject to change without notice.
For Contact information visit our web site. www.crydom.com ©2008 Crydom, Inc. Specifications subject to change without notice.
ANNEX - ENVIROMENTAL INFORMATION For Contact information visit our web site. www.crydom.com ©2008 Crydom, Inc. Specifications subject to change without notice.