Features
1000 VDC electrical isolation Small size Standard TO–72 hermetic package Screened version is available on MCT4R
Description
The MCT4 and MCT4R products are designed especially for high- reliability applications that require optical isolation with high Current Transfer Ratio (CTR) and low saturation V CE. Each optocoupler consists of an LED and N-P-N silicon photo- transistor that is mounted and optically coupled in a four-leaded hermetic TO–18 package. Anode Emitter Cathode Collector 202463-001 Figure 1. MCT4/4R Block Diagram A functional block diagram of the MCT4/4R is shown in Figure 1. Table 1. Electrical specifications are provided in Table 2.
Table 1. MCT4/4R Absolute Maximum Ratings 1 set at or below their nominal value. Exceeding any of the limits listed in the above table may result in permanent damage to the device. 2 Measured between pins 1 and 3 shorted together, and pins 2 and 4 shorted together. TA = 25 °C and duration = 1 s. 3 Value applies for PW ≤1 μs, PRR ≤300 pps. or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Table 2. MCT4/4R Electrical Specifications 1 1 Performance is guaranteed only under the conditions listed in the above table. 2 Measured between pins 1 and 3 shorted together, and pins 2 and 4 shorted together. TA = 25 °C and duration = 1 s.
DATA SHEET • MCT4/4R: PHOTO-TRANSISTOR HERMETIC OPTOCOUPLERS Phone [408] 946-1968 • Fax [408] 946-1960 • hirel.sales@skyworksinc.com • www.skyworksinc.com 6 June 26, 2017 • Isolink Proprietary Inform ation • Products and Product Information are Subject to Change Without Notice • 202463B
Ordering Information
Model Name Manufacturing Part Number MCT4/4R: Photo-Transistor Hermetic Optocouplers MCT4/4R Copyright © 2012, 2017 Isolink, Inc. All Rights Reserved. Information in this document is provided in connection with Isolink, Inc. (“Isolink”), a wholly-owned subsidiary of Skyworks Solutions, Inc. These materials, including the information contained herein, are provided by Isolink as a service to its customers and may be used for informational purposes only by the customer. Isolink assumes no responsibility for errors or omissions in these materials or the information contained herein. Isolink may change its documentation, products, services, specifications or product descriptions at any time, without notice. Isolink makes no commitment to update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes. No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Isolink assumes no liability for any materials, products or information provided hereunder, including the sale, distribution, reproduction or use of Isolink products, information or materials, except as may be provided in Isolink Terms and Conditions of Sale. THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. ISOLINK DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. ISOLINK SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Isolink products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Isolink products could lead to personal injury, death, physical or environmental damage. Isolink customers using or selling Isolink products for use in such applications do so at their own risk and agree to fully indemnify Isolink for any damages resulting from such improper use or sale. Customers are responsible for their products and applications using Isolink products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Isolink assumes no liability for applications assistance, customer product design, or damage to any equipment resulting from the use of Isolink products outside of stated published specifications or parameters. Isolink is a trademark of Isolink Inc. in the United States and other countries. Skyworks and the Skyworks symbol are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for identification purposes only, and are the property of their respective owners.