MC1458, MC1558 DUAL GENERAL-PURPOSE OPERATIONAL AMPLIFIERS SLOS069A – FEBRUARY 1971 – REVISED MAY1999 1POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 /C0068Short-Circuit Protection /C0068Wide Common-Mode and Differential Voltage Ranges /C0068No Frequency Compensation Required /C0068Low Power Consumption /C0068No Latch-Up /C0068Designed to Be Interchangeable With Motorola MC1558/MC1458 and Signetics S5558/N5558
description
The MC1458 and MC1558 are dual general- purpose operational amplifiers, with each half electrically similar to the µA741, except that offset null capability is not provided. The high-common-mode input voltage range and the absence of latch-up make these amplifiers ideal for voltage-follower applications. The devices are short-circuit protected and the internal frequency compensation ensures stability without external components. The MC1458 is characterized for operation from 0°C to 70°C. The MC1558 is characterized for operation over the full military temperature range of –55°C to 125°C. symbol (each amplifier) + IN + OUT IN – AVAILABLE OPTIONS PACKAGE TA VIOmax AT 25°C SMALL OUTLINE (D) CHIP CARRIER (FK) CERAMIC DIP (JG) PLASTIC DIP (P) CERAMIC FLAT PACK (U) 0°C to 70°C 6 mV MC1458CD — — MC1458CP — –55°C to 125°C 5 mV — MC1558MFK MC1558MSG — MC1558MU The D packages are available taped and reeled. Add the suffix R to the device type (i.e., MC1458DR) Copyright 1999, Texas Instruments IncorporatedPRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. On products compliant to MIL-PRF-38535, all parameters are tested unless otherwise noted. On all other products, production processing does not necessarily include testing of all parameters. NC VCC + 2OUT 2IN – 2IN+ NC 1OUT 1IN – 1IN+ V CC – 1OUT 1IN – 1IN+ VCC – VCC + 2OUT 2IN – 2IN+ (TOP VIEW) MC1458 ...D O R P PACKAGE MC1558 . . . JG PACKAGE MC1558 ...U PACKAGE (TOP VIEW) 3212 0 1 9 91 0 1 1 1 2 1 3 NC 2OUT NC 2IN – NC NC 1IN – NC 1IN+ NC MC1558 . . . FK PACKAGE NC 1OUT NC NC NC NC V NC NC – No internal connection CC +V2IN+ CC – (TOP VIEW)
MC1458, MC1558 DUAL GENERAL-PURPOSE OPERATIONAL AMPLIFIERS SLOS069A – FEBRUARY 1971 – REVISED MAY1999
2 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
schematic (each amplifier) IN – IN + OUT VCC + VCC – absolute maximum ratings over operating free-air temperature range (unless otherwise noted) MC1458 MC1558 UNIT Supply voltage (see Note 1) VCC + 18 22 VSupply voltage (see Note 1) VCC – –18 –22 V Differential input voltage (see Note 2) ± 30 ± 30 V Input voltage at either input (see Notes 1 and 3) ± 15 ± 15 V Duration of output short circuit (see Note 4) unlimited unlimited Continuous total dissipation See Dissipation Rating Table Case temperature for 60 seconds: FK package 260 °C Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds JG or U package 300 °C Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds D or P package 260 °C Storage temperature range 65 to 150 –65 to 150 °C NOTES: 1. All voltage values, unless otherwise noted, are with respect to the midpoint between VCC + and VCC – . 2. Differential voltages are at IN+ with respect to IN–. 3. The magnitude of the input voltage must never exceed the magnitude of the supply voltage or 15 V, whichever is less. 4. The output can be shorted to ground or either power supply. For the MC1558 only, the unlimited duration of the short circuit applies at (or below) 125°C case temperature or 70°C free-air temperature. DISSIPATION RATING TABLE PACKAGE TA ≤ 25°C POWER RATING DERATING FACTOR DERATE ABOVE T A TA = 70°C POWER RATING TA = 125°C POWER RATING D 680 mW 5.8 mW/°C 33°C 464 mW —D FK 680 mW 680 mW 5.8 mW/ C 11.0 mW/°C 33 C 88°C 464 mW 880 mW 275 mW JG 680 mW 8.4 mW/°C 69°C 672 mW 210 mW P 680 mW 8.0 mW/°C 65°C 640 mW — U 675 mW 5.4 mW/°C 25°C 432 mW 135 mW
MC1458, MC1558 DUAL GENERAL-PURPOSE OPERATIONAL AMPLIFIERS SLOS069A – FEBRUARY 1971 – REVISED MAY1999 3POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 recommended operating conditions MIN MAX UNIT Supply voltage, VCC ± ± 5 ± 15 V O perating free air temperature range TA MC1458 0 70 °COperating free-air temperature range, TA MC1558 –55 125 electrical characteristics at specified free-air temperature, VCC ± = ± 15 V PARAMETER TEST CONDITIONS † MC1458 MC1558 UNITPARAMETER TEST CONDITIONS † MIN TYP MAX MIN TYP MAX UNIT VIO Input offset voltage VO =0 25°C 1 6 1 5 mVVIO Input offset voltage VO = 0 Full range 7.5 6 mV IIO Input offset current VO =0 25°C 20 200 20 200 nAIIO Input offset current VO = 0 Full range 300 500 nA IIB Input bias current VO =0 25°C 80 500 80 500 nAIIB Input bias current VO = 0 Full range 800 1500 nA VICR Common-mode input 25°C ± 12 ± 13 ± 12 ± 13 VVICR voltage range Full range ± 12 ± 12 V R L = 10 kΩ 25°C ± 12 ± 14 ± 12 ± 14 VOM Maximum peak output R L ≥ 10 kΩ Full range ± 12 ± 12 VVOM voltage swing R L = 2 kΩ 25°C ± 10 ± 13 ± 10 ± 13 V R L ≥ 2 kΩ Full range ± 10 ± 10 AVD Large-signal differentialR L ≥ 2k Ω VO = ± 10 V 25°C 20 200 50 200 V/mVAVD gg voltage amplificationR L ≥ 2 kΩ , VO = ± 10 V Full range 15 25 V/mV BOM Maximum-output-swing bandwidth (closed loop) R L = 2 kΩ , VO ≥ ± 10 V, AVD = 1, THD ≥ 5% 25°C 14 14 kHz B1 Unity-gain bandwidth 25°C 1 1 MHz φm Phase margin AVD = 1 25°C 65 65 deg Gain margin 25°C 11 11 dB ri Input resistance 25°C 0.3 2 0.3* 2 M Ω ro Output resistance VO = 0, See Note 5 25°C 75 75 Ω C i Input capacitance 25°C 1.4 1.4 pF zic Common-mode input impedance f = 20 Hz 25°C 200 200 M Ω CMRR Common-mode VIC = VICR min, 25°C 70 90 70 90 dBCMRR rejection ratio IC ICR , VO = 0 Full range 70 70 dB kSVS Supply-voltage sensitivity VCC = ± 9 V to ± 15 V, 25°C 30 150 30 150 µV/VkSVS sensitivity (ΔVIO/ΔVCC ) CC , VO = 0 Full range 150 150 µV/V Vn Equivalent input noise voltage (closed loop) AVD = 100, R S = 0, f = 1 kHz, BW = 1 Hz 25°C 45 45 nV/√Hz *On products compliant to MIL-PRF-38535, this parameter is not production tested. † All characteristics are specified under open-loop operating conditions with zero common-mode input voltage unless otherwise specified. Full range for MC1458 is 0°C to 70°C and for MC1558 is –55°C to 125°C. NOTE 5: This typical value applies only at frequencies above a few hundred hertz because of the effect of drift and thermal feedback.
4 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
† All characteristics are specified under open-loop operating conditions with zero common-mode input voltage unless otherwise specified. Full range for MC1458 is 0°C to 70°C and for MC1558 is –55°C to 125°C. Figure 1. Rise-Time, Overshoot, and Slew-Rate Waveform and Test Circuit
Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue any product or service without notice, and advise customers to obtain the latest version of relevant information to verify, before placing orders, that information being relied on is current and complete. All products are sold subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those pertaining to warranty, patent infringement, and limitation of liability. TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily performed, except those mandated by government requirements. CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO BE FULLY AT THE CUSTOMER’S RISK. In order to minimize risks associated with the customer’s applications, adequate design and operating safeguards must be provided by the customer to minimize inherent or procedural hazards. TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right of TI covering or relating to any combination, machine, or process in which such semiconductor products or services might be or are used. TI’s publication of information regarding any third party’s products or services does not constitute TI’s approval, warranty or endorsement thereof. Copyright 1999, Texas Instruments Incorporated