MC050-110 DANFOSS | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 4

Technical content

Features

  • User-programmable with PLUS+1 GUIDE (Graphical User Integrated Development Environment)
  • 50 pins: (1) DEUTSCH DRC connector
  • ARM 32 bit Cortex-M3 running at 120 MHz
  • FRAM non-volatile memory
  • 12 bit analog-to-digital converter
  • 9 to 36 Vdc power supply, monitored internally
  • 2 CAN 2.0 B ports, the fixed range analog input can be configured as the shield pin
  • Power supply for external sensors rated at 5 Vdc to 450 mA, monitored and regulated internally
  • 2 LEDs under user control
  • 3 mounting alternatives: stack, end, or side
  • MC050-112 contains application key required to run Danfoss developed machine control application software
  • CE compliant Comprehensive technical literature is online at www.danfoss.com Data Sheet PLUS+1® Controllers MC050-110 and MC050-112 © Danfoss | June 2020 AI152986480864en-000203 | 1
  • (6) universal (DIN/AIN/FreqIN) that are user-defined as either: ‒ Analog: with configurable ranges 0 to 5.25 Vdc (with over range protection) or 0 to 36 Vdc ‒ Digital: pull up (5 Vdc), pull down (0 Vdc) or pull to center (2.5 Vdc) ‒ Frequency (timing): 1 Hz to 10 kHz
  • (6) digital (DIN) configurable as pull up (5 Vdc), pull down (0 Vdc)
  • (4) digital/analog (DIN/AIN) that are user defined as either: ‒ Digital: pull up (5 Vdc), pull down (0 Vdc) or pull to center (2.5 Vdc) ‒ Analog: 0 to 5.25 Vdc or 0 to 36 Vdc
  • (4) analog (AIN/Temp/Rheo) 0 to 5.25 Vdc or 0 to 10,000 ohm rheostat
  • (2) fixed range analog (AIN/CAN shield) 0 to 5.25 Vdc or CAN shield pin

16 Outputs

  • (10) universal (PWMOUT/DOUT/ PVGOUT) that are user-defined as either: ‒ Digital: (3 A), configurable as source or sink ‒ PWM: (30 to 4000 Hz), configurable as open or closed loop with current control ‒ Analog voltage: open loop PWM at 4000 Hz
  • Any PWMOUT/DOUT/PVGOUT can be used to provide reference power to one PVG valve
  • (3) digital (DOUT) (3 A), configurable as source only
  • (3) digital/PVG power supply (DOUT/PVG Pwr) (3A), user- configurable; one DOUT/PVG Pwr willpower up to three PVGs Data Sheet MC050-110 and MC050-112 Controllers 2 | © Danfoss | June 2020 AI152986480864en-000203

mm [in] 47.1 [1.85] 51.6 [2.03] 193.8 [7.63] 159.7 [6.29] 144.5 [5.69] 114.4 [4.50] 147.5 [5.81] 35.7 [1.41] 139.11 [5.50] 32.4 [1.27] 2197A CCaution PCB damage may occur. All device power supply + pins must be connected to battery +. This device is not field serviceable. Opening the device housing will void the warranty. Technical Specifications Supply voltage 9 to 36 Vdc Operating temperature (ambient) -40°C to 70°C [-40°F to 158°F] Storage temperature -40°C to 85°C [-40°F to 185°F] Programming temperature -40°C to 70°C [-40°F to 158°F] IP rating (with mating connector attached) IP 67 EMI/RFI rating 100 V/M Weight 0.53 kg [1.16 lb] Vibration IEC 60068-2-64 Shock IEC 60068-2-27 test Ea Maximum current, sourcing 40 A Maximum current, sinking 8 A

Ordering information

Related product Danfoss material number CG150 CAN/USB Gateway 10104136 DEUTSCH mating connector bag assembly 10102024 (16 to 20 AWG) 10100946 (20 to 24 AWG) PLUS+1® GUIDE single user license 10101000 Data Sheet MC050-110 and MC050-112 Controllers © Danfoss | June 2020 AI152986480864en-000203 | 3

C1-P1 Power ground - C1-P26* DIN/AIN/FreqIN C1-P2 Power supply + C1-P27 AIN/Temp/Rheo C1-P3 CAN0 + C1-P28 AIN/Temp/Rheo C1-P4 CAN0 - C1-P29 AIN/Temp/Rheo C1-P5 AIN/CAN0 shield C1-P30 AIN/Temp/Rheo C1-P6 DIN C1-P31 DOUT C1-P7 DIN C1-P32 DOUT C1-P8 5 Vdc sensor power + C1-P33 DOUT C1-P9 Sensor power ground - C1-P34 DOUT/PVG Pwr C1-P10 DIN C1-P35 DOUT/PVG Pwr C1-P11 DIN C1-P36 DOUT/PVG Pwr C1-P12 DIN C1-P37 PWMOUT/ DOUT/PVGOUT C1-P13 DIN C1-P38 PWMOUT/ DOUT/PVGOUT C1-P14 DIN/AIN C1-P39 PWMOUT/ DOUT/PVGOUT C1-P15 DIN/AIN C1-P40 PWMOUT/ DOUT/PVGOUT C1-P16 DIN/AIN C1-P41 PWMOUT/ DOUT/PVGOUT C1-P17 DIN/AIN C1-P42 PWMOUT/ DOUT/PVGOUT C1-P18 DIN/AIN/FreqIN C1-P43 PWMOUT/ DOUT/PVGOUT C1-P19 DIN/AIN/FreqIN C1-P44 PWMOUT/ DOUT/PVGOUT C1-P20 CAN1 + C1-P45 PWMOUT/ DOUT/PVGOUT C1-P21 CAN1 - C1-P46 PWMOUT/ DOUT/PVGOUT C1-P22 AIN/CAN1 shield C1-P47 Power supply + C1-P23 DIN/AIN/FreqIN C1-P48 Power supply + C1-P24 DIN/AIN/FreqIN C1-P49 Power supply + C1-P25 DIN/AIN/FreqIN C1-P50 Power supply + Use care when wiring mating connector. Above pinouts are for device pins. Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. 4 | © Danfoss | June 2020 AI152986480864en-000203