Features
User-programmable with PLUS+1 GUIDE (Graphical User Integrated Development Environment 32 bit fixed-point DSP running at 150 MHz ‒ 12 bit analog-to-digital converter ‒ 16 bit timers/counters 12 pin DEUTSCH DTM connector 9 to 36 Vdc power supply, monitored internally 1 CAN 2.0B port, the fixed range analog input can be configured as the shield pin Power supply for external sensors rated at 5 Vdc to 100 mA and regulated internally 2 LEDs under user control 3 mounting alternatives: stack, end , or side The MC012-029 controller contains the application key required to run Danfoss developed machine control application software CE compliant Comprehensive technical literature online at powersolutions.danfoss.com Data Sheet PLUS+1® Controllers MC012-026 and MC012-029 © Danfoss | June 2017 AI00000142en-US0204 | 1
(3) universal (DIN/AIN/FreqIN/Rheo) that are user-defined as either: ‒ Analog: with configurable ranges 0 to 5.25 Vdc (with over range protection) or 0 to 36 Vdc ‒ Digital: pull up (5 Vdc), pull down (0 Vdc) or pull to center (2.5 Vdc) ‒ Frequency (timing): 1 Hz to 10 kHz ‒ Resistance: 0 to 10,000 ohm (1) fixed range analog (AIN/CAN shield) 0 to 5.25 Vdc or CAN shield pin 2 outputs (2) universal (PWMOUT/DOUT/PVGOUT) that are user-defined as either: ‒ Digital: (3 A), configurable as source or sink ‒ PWM: (30 to 4000 Hz), configurable as open or closed loop with current control ‒ Analog voltage: open loop PWM at 4000 Hz Any PWMOUT/DOUT/PVGOUT can be used to provide reference power to one PVG valve Characteristics Supply voltage 9 to 36 VDC Operating temperature (ambient) – 40°C to 105°C [– 40°F to 221°F] Storage temperature – 40°C to 105°C [– 40°F to 221°F] Programming temperature 0°C to 70°C [32°F to 158°F] IP rating (with mating connector attached) IP 67 EMI/RFI rating 100 V/M Weight 0.40 kg [0.88 lb] Vibration IEC 60068-2-64 Shock IEC 60068-2-27 test Ea Maximum current, sourcing 8 A Maximum current, sinking 8 A Data Sheet MC012-026 and 029 2 | © Danfoss | June 2017 AI00000142en-US0204
Dimensions and pin assignments Dimensions in mm [in] 51.6 [2.03] 47.1 [1.85] 114.4 [4.50] 158.2 [6.23] 25.2 [1.0] 142.0 [5.59] 97.0 [3.82] 35.0 [1.38] 144.5 [5.69] Use care when wiring mating connector. Pinouts are for device pins. DEUTSCH DT Series 12 pin 2200B Pin Controller function Pin Controller function
1 Power ground- 7 Sensor power ground-
2 Power supply+ 8 DIN/AIN/FreqIN/Rheo
3 CAN+ 9 DIN/AIN/FreqIN/Rheo
4 CAN- 10 DIN/AIN/FreqIN/Rheo
5 AIN/CAN shield 11 PWMOUT/DOUT/
6 5 Vdc sensor power+ 12 PWMOUT/DOUT/ PVGOUT CCaution Warranty will be voided if device is opened. Device is not field serviceable. Do not open the device. Data Sheet MC012-026 and 029 © Danfoss | June 2017 AI00000142en-US0204 | 3
Ordering information
MC012-026 part number 11075252 MC012-029 part number 11075253 Related products part numbers CG150 CAN/USB Gateway 11153051 DEUTSCH mating connector bag assembly 10102025 (16 to 20 AWG) 10100944 (20 to 24 AWG) PLUS+1 GUIDE Professional 11179523 Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. 4 | © Danfoss | June 2017 AI00000142en-US0204