150W Open Frame Switching Power Supplies For Medical Equipment. The MBU150 series of compact, open frame constructed, AC/DC switching mode power supplies provide 150 Watts of continuous output power.They are suited for use in hospital instrument and many other applications. All models meet FCC Part-18 class B and CISPR-11 EN55011 class B emission Limits and are designed to ndcomply with UL/c-UL(UL 60601-1:2 Edition) and new CE requirements. All units are 100% burned in and tested. Electrical Characteristics: Features: Description: Typ. Parameter Test Conditions Min. Max. Unit 0.95 0.97 1.0 1.2 0.5 1 -0.04 0.04 Vin=100 to 240 VAC Io=Full load, Vin=100~240VAC Io=Full load, Vin=115VAC Vin=230VAC W V A A A A A Input Voltage Output Power Range Power Factor Correction Efficiency Line Regulation Load Regulation Over Voltage Protection Time of Transient Response Hold-Up Time Safety Ground Leakage Current Temperature Coefficient S mA mS 240 100 See rating Chart 28 31 57 63 0.10.075 0.5 Low Line Inrush Current VAC Hz Sym. Iil Irh Eff REG-i REG-o OVP OCP Ttr Thold Ts Vp-p Ilk Iih Irl TC Vin fin Po PF Vo Io 150 8785 82 132 150 110 112 High Line Inrush Current Input Frequency Output Voltage Range Output Current Range Input Current (Low Line) Input Current (High Line) Io=Full load, Vin=230VAC Io=Full load, 25 C,Cool start, Vin=115VAC Io=Full load, 25 C,Cool start, Vin=230VAC Io=Full load, Vin=110VAC Io=Full load Over Current Protection Io=Full load to Half Load, Vin=100VAC Start Up Time Io=Full load, Vin=100VAC Ripple & Noise (Peak to Peak) Full load, Vin=90VAC 1 % Io=Full load, Vin=240VAC See rating Chart mS20 %/ C Io=Full load, Vin=230VAC All output Operating Voltage Wide Input Voltage 100 to 240 VAC,47 to 63 Hz Internal EMI filter Single Output Input connector mates with Molex housing 09-50-3051 and Molex 2478 series crimp terminal Output connector mates with Molex housing 09-50-3081 and Molex 2478 series crimp terminal Input Surge Current, Over Voltage and Over Load protection Output Voltage Protection(Crowbar Design) Active Power Factor Correction Size: 3"x5"x1.44” Class I 3 year warranty Safety Approvals : CBCB EN 60601-1 IEC 60601-1 Environmental : Toper Operating Temperature Tstg Storage Temperature 0 70 -40 Sym. Parameter Min. Typ. Max. UnitTest Conditions C C Hr Ho Storage Humidity 75 % %Operating Humidity Pd 95 0 Derate linearly from 100% load at 50 C to 50% load at 70 C Hrs MTBF Operating Temperature at 25 C, Calculated per MIL-HDBK-217F 0.1M

Output Voltage And Current Rating Chart (Single Output) : Mechanical Specifications : MBU150 SERIES 150W Open Frame Switching Power Supplies For Medical Equipment. Note: 1. Dimensions are shown in inches or mm. 2. Weight: 420gs approx. 3. Input connector mates with Molex housing 09-50-3051 and Molex 2478 series crimp terminal. 4. Output connector mates with Molex housing 09-50-3081 and Molex 2478 series crimp terminal PIN CHART MODEL PIN MBU150-1XX 1 2 3 4 5 6 7 8 Vout Vout RTN RTN RTN RTNVout Vout Safety Specifications: Parameter Test Conditions Min. Typ. Max. Unit Dielectric Withstanding Voltage for Primary to secondary Primary to secondary VDC Primary to ground Test Voltage=500VDC 50 M Vin=220VAC B CLASS Sym. Vps Vpg Ris CISPR FCC Isolation Resistance EMI requirements for CISPR-11 Vin=110VAC VDC B CLASS Dielectric Withstanding Voltage for Primary to Ground EMI requirements for FCC PART-18 5656 2828 LEDLED G N L Model Number Output Voltage Output Current Total Regulation Maximum Output Power MBU150-105 12 VDC 12.50 A 5% 150W MBU150-108 24 VDC 6.25 A 3% 150W