MBR0530_11 UTC | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 3

Technical content

UNISONIC TECHNOLOGIES CO., LTD MBR0530 DIODE www.unisonic.com.tw 1 of 3 Copyright © 2011 Unisonic Technologies Co., Ltd QW-R601-014,B SCHOTTKY RECTIFIER „ FEATURES * For surface mounted applications * Low forward voltage drop (VF=0.37V Typ. at 0.1A) * Guard ring for transient and ESD protection SOD-123 SOD-323 „ ORDERING INFORMATION Ordering Number Lead Free Halogen Free Package Packing MBR0530L-CA2-R MBR0530G-CA2-R SOD-123 Tape Reel MBR0530L-CB2-R MBR0530G-CB2-R SOD-323 Tape Reel „ MARKING

UNISONIC TECHNOLOGIES CO., LTD 2 of 3 www.unisonic.com.tw QW-R601-014,B „ ABSOLUTE MAXIMUM RATINGS (Ta=25℃) PARAMETER SYMBOL RATINGS UNIT Maximum Repetitive Peak Reverse Voltage V RRM 30 V Maximum DC Blocking Voltage V R 30 V Working Peak Reverse Voltage V RWM 30 V Maximum RMS Reverse Voltage V R(RMS) 21 V Maximum Voltage Rate of Change (Rated VR) dv/dt 1000 V/ μs Average Rectified Forward Current I OUT 500 mA Non-Repetitive Peak Forward Surge Current I FSM 5.5 A Power Dissipation P D 410 mW Storage Temperature T STG -65 ~ +150 ℃ Note: Absolute maximum ratings are those values beyond which the device could be permanently damaged. Absolute maximum ratings are stress ratings only and functional device operation is not implied. „ THERMAL DATA PARAMETER SYMBOL RATINGS UNIT Junction to Ambient θJA 244 ℃/W „ ELECTRICAL CHARACTERISTICS (TA=25℃, unless otherwise specified) PARAMETER SYMBOL TEST CONDITIONS MIN TYP MAX UNIT Reverse Breakdown Voltage BV R I R=130μA 30 V VF1 I F=0.1A 0.375Forward Voltage Drop VF2 I F=0.5A 0.430 V IR1 V R=15V 20 Reverse Leakage Current IR2 V R=30V 130 μA Total Capacitance C T V R=1V, f=1MHz 170 pF Typical Reverse Recovery Time t RR IF=IR=10mA, RL=100Ω, recover to 0.1 x IR 4 ns

UNISONIC TECHNOLOGIES CO., LTD 3 of 3 www.unisonic.com.tw QW-R601-014,B „ TYPICAL CHARACTERISTICS Total Capacitance, CT (pF) Instantaneous Forward Current, IF (A) 0.2 0.4 0.6 0.8 Average Rectified Forward Current, IOUT (A) 50 125 150 Lead Temperature, TL (℃) 25 75 100 Forward Current Derating Curve UTC assumes no responsibility for equipment failures that result from using products at values that exceed, even momentarily, rated values (such as maximum ratings, oper ating condition ranges, or other parameters) listed in products specifications of any and all UTC products described or contained herein. UTC products are not designed for use in lif e support appliances, devices or systems where malfunction of these products can be reasonably expe cted to result in personal injury. Reproduction in whole or in part is prohibited without the prior writ ten consent of the copyright owner. The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice.