MB13 -SERIES Three Phase Input Noise Filter with Block Terminal m Features (1)Block Terminal with Cover Simple wire connection by block terminal. High safety by terminal cover. (2)Three Phase Power Line Filter Available for Star connection : 400Vac line-line Available for Delta connection : 200Vac line-line (3)High Attenuation in Compact Package m Safety standard UL1283, CSA Std. C22. 2 No. 8 EN133200 (New European Standard) m Specifications mDERATING mAPPLICATIONS mCIRCUIT Star connection 3 Phase 4 Wires 400V line-line. Unused Neutral line Note: For inverter application Do not use MB series between inverter and motor. Delta Connection
3 Phase 3 Wires 200V line-line
MB1310 MB1320 MB1330 MB1340 MB1350MODELITEMS
1 Rated Voltage (AC) 500V(50/60Hz)
2 Rated Current (AC) (Note 1) 10A 20A 30A 40A 50A
3 Test Voltage 2500VAC(20mA) Terminal to case, 1min. at 25˚C , 70%RH 4 Isolation Resistance 100M Ω min. Terminal to case, 500VDC at 25˚C, 70%RH
5 Leakage Current
250V 60Hz 1.0mA max. 500V 60Hz 2.0mA max. 7 Temperature Rise 35˚C max.
8 Operating Temperature –25˚C~+85˚C
9 Operating Humidity 30%~95% RH (No Dewdrop)
10 Storage Temperature –40˚C~+85˚C
11 Storage Humidity 10%~95% RH (No Dewdrop)
12 Vibration 10~55~10Hz,Amplitude (Sweep for 1min) 1.5mm(9G max.) X,Y,Z 2 hours each 13 Safety Standard Bilt to meet : UL1283,CSA C22.2 No.8, EN133200
14 Weight (typ) 1800g 1800g 1800g 2800g 2800g
15 MTBF(hours) (Note 2) 573,000 480,000 521,000 421,000 395,000
(Note1): Value for Ta 50°C. For Ta>50°C derate according to the derating curve shown below. (Note2): Calculated based on the part stress analysis prediction method as specified in MIL-HDBK-217F. noise filter noise filter noise filter Inverter motor noise filter noise filter
(Unit: mm) Model Name Model Name Mounting Holes Mounting Holes Mounting Holes
Frequency (MHz) Attenuation (dB) Frequency (MHz) Frequency (MHz) Attenuation (dB) Attenuation (dB) Frequency (MHz) Attenuation (dB) Frequency (MHz) MB1310 MB1320 MB1330 MB1340 MB1350 Attenuation (dB) CHARACTERISTICS m Typical Insertion Loss (1) Asymmetrical
Attenuation (dB) Frequency (MHz) Attenuation (dB) Frequency (MHz) Attenuation (dB) Frequency (MHz) Attenuation (dB) Frequency (MHz) Attenuation (dB) Frequency (MHz) MB1310 MB1320 MB1330 MB1340 MB1350 CHARACTERISTICS m Typical Insertion Loss (2) Symmetrical