Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 • 805-486-4565  FAX 805-487-8911  www.condorpower.com MAX-500 Multiple Watt Output SPECIFICATIONS: INPUT Ac Input: 90-132 Vac/180-264 Vac, 47 to 63 Hz. User selectable. See option “A” for automatic line selection. Internally fused for 12 A. Inrush: Cold start ac current is less than 80 A at 115 Vac and 20 A at 230 Vac. Limited by thermistor. Holdup Time: 16 ms minimum after removal of power, at nominal line, full load. Efficiency: 80% typical. Brownout Protection: Holds regulation to 85 Vac or 170 Vac. OUTPUT Adjustability: User adjustable ±5% minimum. Line & Load Reg: ±1% over ac input range and 0 to 100% load change. Output #1 requires minimum load of 10%. Ripple & Noise: Less than 1% p-p or 100 mV, whichever is greater. Remote Sense (Output #1): Compensates for 250 mV total line drop. Open sense lead protection. Temperature Coefficient: 0.02% per degree C. Stability: 0.1% over 8 hours after 30 minutes warm-up. Transient Response (Output #1): Output voltage returns to within 1% in less than 500 µs for a 50% load change. Peak transient does not exceed 5%. Overload Protection: All outputs are protected against overload and short circuit. Automatic recovery upon removal of fault. Overvoltage Protection (Output #1): Protects load against power supply induced overvoltage. Trip point is factory set so that output voltage cannot exceed 136% of nominal. Remote Inhibit: Contact closure to the negative sense line drops output power to nominal zero. Reverse Voltage: Protected against reverse voltage up to supply current rating. ENVIRONMENTAL Thermal Protection: Shuts down power supply if overheated. Automatic recovery. Temperature Range: 0° to 50°C at full ratings. Derate to half power at 70°C. Safety Agencies: Most models are approved to UL1950; CSA 22.2 #234; IEC 950 and TÜ V EN60950, Class 1 SELV., CE 72/23/ EEC/93/68EEC (low voltage directive). Conducted RFI: Meets FCC Part 15, Subpart J, Class A; EN55022 Class B; CISPR 22 Class B. Cooling: 30 cfm required to achieve full ratings. Output Isolation: Isolated from ground 50 Vdc. OPTIONS: Option “A”, Ac Auto-Range: Automatically selects proper ac line voltage range to enable power operation at either 115 or 230 Vac without user intervention. Option “F”, Fan/Cover Assembly: Cover with intergal ball- bearing fan provides proper cooling to achieve full ratings at 50°C ambient temperature. Option “P”, Ac Power Fail: Provides TTL “0” 5 ms before output voltage goes out of regulation band upon loss of ac power. VMEbus compatible, provides 48 mA sink current capability. Not available if option “G ” is selected. Option “V”, Fan/Cover Assembly: Low profile, end venting cover with integral ball-bearing fan. FEATURES:  Over 3.5 watts/in3 power density  80% overall efficiency  VMEbus and Multibus II system compatibility  Meets international safety agency requirements  All outputs regulated ±1%  High peak currents for motor starting  System air or self-cooling options  Ac automatic line selection option Option V NOITCNUF CAV511 CAV032 ROTCENNOC tceleStupnIt rohSn epOs notsaFelaM052.0 )L(-1-BTe niL1 eniL2 3-6#pirtsreirraB )N(-1BTl artueN2 eniL. sretnec8/3swercs )DNG(-1BTd nuorGytefaSd nuorGytefaS NOITCNUF NOITACOL SETON ROTCENNOC 1#tuptuOV +dekramlanimreTt uptuOniaMs rabsuB MOCdekramlanimreT) nommoc(ntRs wercs02-4/1# 2#tuptuO3 -2BT 4-2BT) nommoc(ntR 3#tuptuO5 -2BT "8.3swercs23-6#pirtsreirraB 4-2BT) nommoc(ntRs retnec 4#tuptuO1 -2BT) +( 2-2BT) -( NOITCNUF NOITACOL SETON ROTCENNOC esneSetomeR) S+(1-1Je sneS1#tuptuOe pytATMPMA )S-(2-1Jn tResneS1#tuptuOn ip4-654046# liaFrewoPcA) FP(3-1J2 -1JotecnerefeR) gnikcol(redaeh *dooGrewoPcD tibihnI) H1(4-1J2 -1JottrohS AC INPUT DC OUTPUT STATUS AND CONTROL * Optional function NON-STOCK ITEM; SPECIAL ORDER ONLY NOT FOR NEW DESIGNS

Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929  805-486-4565  FAX 805-487-8911  www.condorpower.com MAX-500 MECHANICAL SPECIFICATIONS MAX-500 Multiple Watt Output Dimensions: Inches Millimeters ledoMlaicremmoC tuOrewoP .oNtuptuO tuptuO tnerruC )A(noitalugeRlatoT FA5021-405-XAM0 051 V 5+A 081 ± PA5021-405-XAM2 V 21+k pA61/011 ± 3V 21-A 011 ± 4V 2.5A 21 ± VA2121-405-XAM0 051 V 5+A 081 ± 2V 21+k pA61/011 ± 3V 21-A 011 ± 4V 21A 21 ± 4221-405-XAM0 051 V 5+A 081 ± 2V 21+k pA61/011 ± 3V 21-A 011 ± 4V 42+A 21 ± Note: (A) Output #1 requires minimum load of 10%