FEATURES
►SIP Package with Industry Standard Pinout ►Package Dimension: ►Single and Dual Output Models ►I/O-Isolation 3000 VDC ►Operating Temp. Range -40°C to +85°C ►3 Years Product Warranty PRODUCT OVERVIEW The MAU200 series is a range of 1W DC/DC converters in a small SIP Package featuring high I/O-isolation of 3000VDC. An excellent efficiency allows an operating temperature range of –40°C to +85°C. These converters offer an economical solution for many applications where a voltage has to be isolated i.e for noise reduction, ground loop elimination, digital interfaces or for board level power distribution where a higher I/O-isolation is required. Model Selection Guide Output Current Input Current Efficiency (typ.) Input Voltage (Range) Output Voltage Max. Min. @Max. Load @No Load Load Regulation Max. capacitive Load @Max. Load Model Number VDC VDC mA mA mA(typ.) mA(typ.) % (max.) µF % MAU201 3.3 260 5 235 10 73 MAU202 5 200 4 281 10 71 MAU203 9 110 2 260 8 76 MAU204 12 84 1.5 258 7 78 MAU205 15 67 1 258 7 220 MAU206 ±5 ±100 ±2 278 10 72 MAU207 ±9 ±56 ±1 262 8 77 MAU208 ±12 ±42 ±0.8 258 7 78 MAU209 (4.5 ~ 5.5) ±15 ±34 ±0.7 258 100# MAU211 3.3 260 5 96 8 74 MAU212 5 200 4 114 8 73 MAU213 9 110 2 106 5 78 MAU214 12 84 1.5 105 5 80 MAU215 15 67 1 104 5 220 MAU216 ±5 ±100 ±2 113 8 74 MAU217 ±9 ±56 ±1 106 5 79 MAU218 ±12 ±42 ±0.8 104 5 81 MAU219 (10.8 ~ 13.2) ±15 ±34 ±0.7 105 100# MAU221 3.3 260 5 49 8 73 MAU222 5 200 4 59 8 71 MAU223 9 110 2 54 5 76 MAU224 12 84 1.5 54 5 78 MAU225 15 67 1 53 5 220 MAU226 ±5 ±100 ±2 58 8 72 MAU227 ±9 ±56 ±1 55 5 76 MAU228 ±12 ±42 ±0.8 53 5 79 MAU229 (21.6 ~ 26.4) ±15 ±34 ±0.7 53 100# # For each output Total Power InTotal Power International, Inc Toll Free: 877-646-0900 www.total-power.com
DC/DC CONVERTER 1W, SIP -Package, High Isolation Input Specifications Parameter Model Min. Typ. Max. Unit 5V Input Models 4.5 5 5.5 12V Input Models 10.8 12 13.2 Input Voltage Range 24V Input Models 21.6 24 26.4 5V Input Models -0.7 --- 9 12V Input Models -0.7 --- 18 Input Surge Voltage (1 sec. max.) 24V Input Models -0.7 --- 30 VDC Reverse Polarity Input Current --- --- 0.3 A Internal Filter Type Internal Capacitor Internal Power Dissipation All Models --- --- 450 mW Output Specifications Parameter Conditions Min. Typ. Max. Unit Output Voltage Accuracy --- ±1.0 ±3.0 % Output Voltage Balance Dual Output, Balanced Loads --- ±0.1 ±1.0 % Line Regulation For Vin Change of 1% --- ±1.2 ±1.5 % Load Regulation Io=20% to 100% See Model Selection Guide Ripple & Noise max. 20MHz Bandwidth --- 65 100 mV P-P Temperature Coefficient --- ±0.01 ±0.02 %/℃ Short Circuit Protection 0.5 Second Max. General Specifications Parameter Conditions Min. Typ. Max. Unit I/O Isolation Voltage (rated) 60 Seconds 3000 --- --- VDC I/O Isolation Resistance 500 VDC 10 --- --- GΩ I/O Isolation Capacitance 100KHz, 1V --- 60 100 pF Switching Frequency 70 100 120 KHz MTBF (calculated) MIL-HDBK-217F@25℃, Ground Benign 2,000,000 --- --- Hours Input Fuse 5V Input Models 12V Input Models 24V Input Models 500mA Slow-Blow Type 200mA Slow-Blow Type 100mA Slow-Blow Type Environmental Specifications Parameter Conditions Min. Max. Unit Operating Ambient Temperature Range (See Power Derating Curve) Natural Convection -40 +85 ℃ Case Temperature --- +90 ℃ Storage Temperature Range -50 +125 ℃ Humidity (non condensing) --- 95 % rel. H Cooling Free-Air convection Lead Temperature (1.5mm from case for 10Sec.) --- 260 ℃ Total Power InTotal Power International, Inc Toll Free: 877-646-0900 www.total-power.com Total Power International, Inc.
DC/DC CONVERTER 1W, SIP-Package, High Isolation Power Derating Curve Ambient Temperature 100 -40 0 20 60 100 1108040 400LFM 200LFM 100LFM Natural Convection 20LFM /uni0043 Output Power (%) (3.3V, 5V & ±5V} (all other output) Notes 1 Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted. 2 Ripple & Noise measurement bandwidth is 0-20MHz. 3 These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these modules; however they may not meet all specifications listed. 4 All DC/DC converters should be externally fused at the front end for protection. 5 Other input and output voltage may be available, please contact factory. 6 That “natural convection” is about 20LFM but is not equal to still air (0 LFM). 7 Specifications are subject to change without notice. Package Specifications Mechanical Dimensions Pin Connections Pin Single Output Dual Output 1 +Vin +Vin 2 -Vin -Vin 5 -Vout -Vout
6 No Pin Common
T: 6.1mm(0.24 inch) for 5V&12V Input Models T: 7.1mm(0.28 inch) for 24V Input Models ►All dimensions in mm (inches) ►Tolerance: X.X±0.25 (X.XX±0.01) X.XX±0.13 ( X.XXX±0.005) Physical Characteristics C ase Material : Non-Conductive Black Plastic (flammability to UL 94V-0 rated) Pin Material : Alloy 42 Weight (5V&12V Input) : 2.2g Weight (24V Input) : 2.6g 3.2 [0.13] 10.2 [0.40] 19.5 [0.77] T 0.50 [0.02] 18.5 [0.73] 0.25 [0.01] 1.3 [0.05] 2.54 [0.10] 7.62 [0.30] 2X2.54 [2X0.10] 0.5 [0.02] 0.5 [0.02] 1 2 75 6 Bottom View 2.4 [0.09] Total Power InTotal Power International, Inc Toll Free: 877-646-0900 www.total-power.com Total Power International, Inc.
DC/DC CONVERTER 1W, SIP-Package, High Isolation Test Setup Peak-to-Peak Output Noise Measurement Test Use a Cout 0.33µF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between 50 mm and 75 mm from the DC/DC Converter. +Out -Out +Vin -Vin Single Output DC / DC Converter Resistive LoadScope Copper Strip Cout Copper Strip +Out -Out +Vin -Vin Dual Output DC / DC Converter Resistive Load Scope Copper Strip Cout Com. ScopeCout Copper Strip Copper Strip Technical Notes Maximum Capacitive Load The MAU200 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up, affecting the ramp-up and the startup time. For optimum performance we recommend 100µF maximum capacitive load for dual outputs and 220µF capacitive load for single outputs. The maximum capacitance can be found in the data sheet. Input Source Impedance The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup. Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR < +Out -Out +Vin -Vin DC / DC Converter LoadDC Power Source Cin Output Ripple Reduction A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is recommended to use 1.0µF capacitors at the output. +Out -Out +Vin -Vin Load DC Power Source Cout Single Output DC / DC Converter +Out -Out +Vin -Vin Load DC Power Source CoutCom. Dual Output DC / DC Converter Load Cout Thermal Considerations Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the maximum temperature rating of the components inside the power module, the case temperature must be kept below 90℃. The derating curves are determined from measurements obtained in a test setup. DUT Position of air velocity probe and thermocouple 50mm / 2in Air Flow 15mm / 0.6in Total Power InTotal Power International, Inc Toll Free: 877-646-0900 www.total-power.com Total Power International, Inc.