DC-DC CONVERTER 1W, Reinforced Insulation, Medical Safety E-mail:sales@minmax.com.tw Tel:886-6-2923150 2018/05/07 REV:3 Page 1 of 3
FEATURES
►Industrial Standard SIP-7 Package ►I/O Isolation 4000VAC with Reinforced Insulation, rated for 300Vrms Working Voltage ►Low Leakage Current < 2μA ►Operating Ambient Temp. Range -40℃ to 95℃ ►Short Circuit Protection ►Medical EMC Standard with 4th Edition of EMI EN 55011 and EMS EN 60601-1-2 Approved ►Medical Safety with 2xMOPP per 3rd Edition of IEC/EN 60601-1 & ANSI/AAMI ES60601-1 Appr oved with CE Marking PRODUCT OVERVIEW The MINMAX MAU01M series is a new range of medical approved 1W isolated DC-DC converter within encapsulated SIP-7 package which specifically design for medical applications. There are 9 models available for input voltage of 5, 12, 24VDC and 5, 12, 15VDC output. The I/O isolation is specified for 4000VAC with reinforced insulation, which rated for 300Vrms working voltage. Further features include short circuit protection, low leakage current 2μA max. and operating ambient temp. range by -40℃ to 95℃ without derating. MAU01M series conform to 4th edition medical EMC standard, medical safety approval with 2xMOPP (Means Of Patient Protection) per 3rd edition of IEC/EN 60601-1 & ANSI/AAMI ES 60601-1. The MAU01M series offer a economical solution for demanding application in medical instrument requesting a certified supplementary and reinforced insulation system to comply with latest medical safety approval for 2xMOPP requirement. Model Selection Guide Model Number Input Voltage (Range) Output Voltage Output Current Input Current Max. capacitive Load Efficiency (typ.) Max. Min. @Max. Load @No Load @Max. Load VDC VDC mA mA mA(typ.) mA(typ.) μF % MAU01-05S05M (4.5 ~ 5.5) 5 200 4 253 50 220 MAU01-05S12M 12 84 1.68 252 80 MAU01-05S15M 15 68 1.36 252 81 MAU01-12S05M (10.8 ~ 13.2) 5 200 4 105 35 220 MAU01-12S12M 12 84 1.68 104 81 MAU01-12S15M 15 68 1.36 108 79 MAU01-24S05M (21.6 ~ 26.4) 5 200 4 55 20 220 MAU01-24S12M 12 84 1.68 53 79 MAU01-24S15M 15 68 1.36 54 79 Input Specifications Parameter Model Min. Typ. Max. Unit Input Voltage Range 5V Input Models 4.5 5 5.5 VDC 12V Input Models 10.8 12 13.2 24V Input Models 21.6 24 26.4 Input Surge Voltage (1 sec. max.) 5V Input Models -0.7 --- 9 12V Input Models -0.7 --- 18 24V Input Models -0.7 --- 30 Input Filter All Models Internal Capacitor
DC-DC CONVERTER 1W, Reinforced Insulation, Medical Safety E-mail:sales@minmax.com.tw Tel:886-6-2923150 2018/05/07 REV:3 Page 2 of 3 Output Specifications Parameter Conditions Min. Typ. Max. Unit Output Voltage Setting Accuracy --- ±1.0 ±3.0 %Vnom. Line Regulation For Vin Change of 1% --- ±1.2 ±1.5 % Load Regulation Io=10% to 100% --- --- ±10 % Ripple & Noise 0-20 MHz Bandwidth --- --- 75 mV P-P Temperature Coefficient --- ±0.01 ±0.02 %/ ℃ Short Circuit Protection Cont inuous, Automatic Recovery Isolation, Safety Standards Parameter Conditions Min. Typ. Max. Unit I/O Isolation Voltage 60 Seconds Reinforced insulation, rated for 300Vrms working voltage 4000 --- --- VACrms Leakage Current 240VAC, 60Hz --- --- 2 μA I/O Isolation Resistance 500 VDC 10 --- --- G Ω I/O Isolation Capacitance 100KHz, 1V --- 20 --- pF Safety Standards ANSI/AAMI ES 60601-1, CAN/CSA-C22.2 No. 60601-1 IEC/EN 60601-1 3rd Edition 2xMOPP Safety Approvals ANSI/AAMI ES 60601-1 2xMOPP recognition (UL certificate), IEC/EN 60601-1 3rd Edition (CB-report) General Specifications Parameter Conditions Min. Typ. Max. Unit Switching Frequency --- 60 --- kHz MTBF (calculated) MIL-HDBK-217F@25 ℃, Ground Benign 4,373,058 --- --- Hours Environmental Specifications Parameter Conditions Min. Max. Unit Operating Ambient Temperature Range (See Power Derating Curve) Natural Convection -40 +95 ℃ Case Temperature --- +105 ℃ Storage Temperature Range -50 +125 ℃ Humidity (non condensing) --- 95 % rel. H Cooling Natural Convection Lead Temperature (1.5mm from case for 10Sec.) --- 260 ℃ EMC Specifications Parameter Standards & Level Performance EMI Conduction EN 55011, FCC part 15 Class A (5) EMS EN 60601-1-2 4th ESD EN 61000-4-2 Air ± 15kV , Contact ± 8kV A Radiated immunity EN 61000-4-3 10V/m A Fast transient (6) EN 61000-4-4 ±2kV A Surge (6) EN 61000-4-5 ±1kV A Conducted immunity EN 61000-4-6 10Vrms A PFMF EN 61000-4-8 30A/m A
DC-DC CONVERTER 1W, Reinforced Insulation, Medical Safety 18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: sales@minmax.com.tw 2018/05/07 REV:3 Page 3 of 3 Minmax Technology Co., Ltd. Power Derating Curve Notes 1 Specifications typical at Ta=+25 ℃, resistive load, nominal input voltage and rated output current unless otherwise noted. 2 These power converters require a minimu m output loading to maintain specified regulation, operation under no-load conditions will not damage these modules; however they may not meet all specifications listed. 3 We recommend to protect the converter by a slow blow fuse in the input supply line. 4 Other input and output voltage may be av ailable, please contact factory. 5 To meet EN 55011 Class A an external filter, please contact MINMAX. 6 To meet EN 61000-4-4 & EN 61000-4-5 an external capacitor across the input pins is required, please contact MINMAX. 7 That “natural convection” is about 20LFM but is not equal to still air (0 LFM). 8 Specifications are subject to change without notice. Package Specifications Mechanical Dimensions Pin Connection Pin Function 1 +Vin 2 -Vin 6 -Vout 7 +Vout ►All dimensions in mm (inches) ►Tolerance: X.X±0.5 (X.XX±0.02) X.XX±0.25 ( X.XXX±0.01) Physical Characteristics Case Material : Non-Conductive Black Plas tic (flammability to UL 94V-0 rated) Pin Material : Tinned Copper Weight : 4.1g 0.5 [0.02] 2.54 [0.10] 10.16 [0.40] 22.0 [0.87] 21.0 [0.83] 0.50 [0.02] Bottom View 12.5 [0.49]3.2 [0.13] 1 2 76 3.5 [0.14] 2.54 [0.10] 7.5 [0.30] 2.0 [0.08]