Features
Operates DC - 4 GHz on Single Supply ASIC TTL / CMOS Driver Low DC Power Consumption 50 Ohm Nominal Impedance Test Boards are Available Tape and Reel are Available Lead-Free 4 x 6 mm PQFN Package 100% Matte Tin Plating over Copper Halogen-Free “Green” Mold Compound 260°C Reflow Compatible RoHS* Compliant Version of SW90-0002
Description
M/A-COM's MASW -007071-000100 is a SPDT ab- sorptive pHEMT switch with integral TTL driver. This device is in an PQFN plastic surface mount package. This switch offers excellent broadband performance and repeatability from DC to 4 GHz, while maintaining low DC power dissipation. The MASW-007071-000100 is ideally suited for wireless infrastructure applications.
Ordering Information
MASW-007071-000100 Bulk Packaging MASW-007071-0001TR 1000 piece reel MASW-007071-0001TB Sample Test Board Note: Reference Application Note M513 for reel size information. Pin Configuration1,2,3,4 Pin No. Function Pin No. Function
1 NC 17 NC
2 GND 18 C1
3 RFC 19 NC
4 GND 20 VCC
5 NC 21 NC
6 NC 22 NC
7 GND 23 CP1
8 RF1 24 CP2
9 GND 25 NC
10 NC 26 VEE
11 NC 27 NC
12 VEE 28 NC
13 NC 29 NC
14 VCC 30 GND
15 NC 31 RF2
16 NC 32 GND
- Restrictions on Hazardous Substances, European Union Directive 2002/95/EC. 1. NC = No Connection 2. VEE is internally generated and must remain isolated from external power supplies. Generated noise is typical of switching DC-DC Converters. 3. Connections and external components shown in functional schematic are required. 0.1 µF Capacitors need to be located near pins 20 & 26. 4. The exposed pad centered on the package bottom must be connected to RF and DC ground. (For PQFN Packages) Truth Table (Switch) Control Input Condition of the Switch RF Common to each RF Port C1 RF1 RF2
0 Off On
1 On Off
“0” = TTL Low “1” = TTL High
GaAs SPDT Switch, Absorptive, Single Supply, DC-4.0 GHz Rev. V4 MASW-007071-000100 2 2 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support Electrical Specifications: TA = 25°C, Z0 = 50 Parameter Test Conditions Frequency Units Min Typ Max Insertion Loss RFC—RF1,RF2 (Logic per truth table) DC - 4.0 GHz dB — — 1.8 Isolation RF1—RF2 (All Logic “0”) DC - 4.0 GHz dB 30 — — VSWR On (RFC,RF1, RF2) (Logic per truth table) DC - 4.0 GHz Ratio — — 2.0:1 VSWR Off (RF1, RF2) (Logic per truth table) DC - 4.0 GHz Ratio — — 1.8:1 1 dB Compression —
50 MHz
0.5 - 4.0 GHz dBm dBm Input IP3 Two-tone inputs up to +5 dBm 50 MHz 0.5 - 4.0 GHz dBm dBm Ton (50% Control to 10% RF) — ns — 31 — Switching Speed Toff (50% Control to 90% RF) — ns — 19 — Trise (10% to 90% RF) — ns — 6 — Tfall (90% to 10% RF) — ns — 2 — Vcc — — V 4.5 5.0 5.5 VIL VIH LOW-level input voltage HIGH-level input voltage V V 0.0 2.0 0.8 5.0 lin (Input Leakage Current) Vin = VCC or GND — uA -1.0 — 1.0 Icc5 Vcc min to max, Logic “0” or “1” — mA — 5 8 Turn-on Current6 For guaranteed start-up — mA — — 125 ΔIcc (Additional Supply Current Per TTL Input Pin) VCC = Max, Vcntrl = VCC - 2.1 V — mA — — 1.0 Switching Noise Generated from DC-DC Converter with recommended capacitors
3.5 MHz dBm — -93 —
Thermal Resistance θjc — — °C/W — 15 — 5. During turn-on, the device requires an initial start up current (Icc) specified as “Turn-on Current”. Once operational, Icc will drop to the specified levels. 6. The DC-DC converter is guaranteed to start in 100 µs as long as the power supplies have the maximum turn-on current available for start-up.
GaAs SPDT Switch, Absorptive, Single Supply, DC-4.0 GHz Rev. V4 MASW-007071-000100 3 3 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support Absolute Maximum Ratings7,8 Parameter Absolute Maximum Max. Input Power
0.05 GHz
0.5 - 4.0 GHz9 +27 dBm +34 dBm VCC -0.5V ≤ VCC ≤ +6.0V Vin10 -0.5V ≤ Vin ≤ VCC + 0.5V Operating Temperature -40ºC to +85ºC Storage Temperature -65ºC to +125ºC 7. Exceeding any one or combination of these limits may cause permanent damage to this device. 8. M/A-COM does not recommend sustained operation near these survivability limits. 9. When the RF input is applied to the terminated port, the absolute maximum power is +30 dBm. 10.Standard CMOS TTL interface, latch-up will occur if logic sig- nal is applied prior to power supply. Handling Procedures Please observe the following precautions to avoid damage: Static Sensitivity Gallium Arsenide Integrated Circuits are sensitive to electrostatic discharge (ESD) and can be damaged by static electricity. Proper ESD control techniques should be used when handling these devices. Moisture Sensitivity The MSL rating for this part is defined as Level 2 per IPC/JEDEC J -STD-020. Parts shall be stored and/or baked as required for MSL Level 2 parts. Recommended PCB Configuration11 11. Application Note S2083 is available on line at www.macom.com
GaAs SPDT Switch, Absorptive, Single Supply, DC-4.0 GHz Rev. V4 MASW-007071-000100 4 4 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support Functional Schematic12 12. Dual Supply Operation will eliminate the start-up current mentioned in Note 5. It will also eliminate spurious signals caused by the DC-DC converter that are present in single supply operation. Isolation (dB) vs. Frequency Typical Performance Curves Insertion Loss vs. Frequency 0.0 0.4 0.8 1 .2 1 .6 2.0 0 1 000 2000 3000 4000 Frequency (MHz) Insertion Loss (dB) 0 1 000 2000 3000 4000 Frequency (MHz) Isolation (dB) Out - OutR F C - R F n
GaAs SPDT Switch, Absorptive, Single Supply, DC-4.0 GHz Rev. V4 MASW-007071-000100 5 5 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support On VSWR vs. Frequency VSWR (Terminations) vs. Frequency 1 .00 1 .20 1 .40 1 .60 1 .80 2.00 0 1 000 2000 3000 4000 Frequency (MHz) VSWR R F 1, R F 2 R F C 1 .00 1 .20 1 .40 1 .60 1 .80 2.00 0 1 000 2000 3000 4000 Frequency (MHz) VSWR R F 1,R F 2 Typical Performance Curves CSP-1, Lead-Free 4 x 6 mm, 32-lead PQFN† † Reference Application Note M538 for lead-free solder reflow recommendations.
GaAs SPDT Switch, Absorptive, Single Supply, DC-4.0 GHz Rev. V4 MASW-007071-000100 6 6 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support M/A-COM Technology Solutions Inc. All rights reserved. Information in this document is provided in connection with M/A -COM Technology Solutions Inc ("MACOM") products. These materials are provided by MACOM as a service to its customers and may be used for informational purposes only. Except as provided in MACOM's Terms and Conditions of Sale for such products or in any separate agreement related to this document, MACOM assumes no liability whatsoever. MACOM assumes no responsibility for errors or omissions in these materials. MACOM may make changes to specifications and product descriptions at any time, without notice. MACOM makes no commitment to update the information and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to its specifications and product descriptions. No license, express or implied, by estoppels or otherwise, to any intellectual property rights is granted by this document. THESE MATERIALS ARE PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, RELATING TO SALE AND/OR USE OF MACOM PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, CONSEQUENTIAL OR INCIDENTAL DAMAGES, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. MACOM FURTHER DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. MACOM SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS, WHICH MAY RESULT FROM THE USE OF THESE MATERIALS. MACOM products are not intended for use in medical, lifesaving or life sustaining applications. MACOM customers using or selling MACOM products for use in such applications do so at their own risk and agree to fully indemnify MACOM for any damages resulting from such improper use or sale.