MAP80 BEL | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 5
Technical content
Bel Power Solutions MAP80 Series of power supplies provides reliable, tightly -regulated DC power for commercial and industrial systems which require high peak current capabilities. Wide-range AC input and full international safety, EMI, and ESD compliance ensure worldwide acceptance. All units bear the CE Mark. The MAP80 utilizes a variable frequency design with a thermally efficient U -channel chassis to provide full power operation in convection-cooled applications. Design innovations include metric and SAE mounting inserts on each mounting surface to provide integration flexibility. Dual -mode connectors provide traditional terminal block connections or popular single -row Molex conn ector mating. Single-output models feature wide-range output adjustability to meet a wide variety of standard and user -specific output voltage requirements. RoHS Compliant Wide Range Input for 110/220 VAC Applications CE marked to Low Voltage Directive Input Transient and ESD Compliance to EN61000-4-2/-3/-4 Meets EN55022, Class B Limits TTL Compatible Power Fail Signal Greater than 175,000 Hours MTBF Metric and SAE Mounting Inserts
2 MAP80 Series
tech.support@psbel.com MODEL7 OUTPUT VOLTAGE ADJUSTMENT RANGE MAX OUTPUT CURRENT PEAK OUTPUT CURRENT1 LINE REGULATION LOAD REGULATION RIPPLE NOISE2 INITIAL SETTING ACCURACY MODEL7 OUTPUT VOLTAGE ADJUSTMENT RANGE OUTPUT CURRENT PEAK OUTPUT CURRENT4 LINE REGULATION LOAD REGULATION RIPPLE NOISE2 INITIAL SETTING ACCURACY MAP80-4000G5 -5V Fixed 1A 1A 0.5% 2% 1% -4.8V to -5.4V -12V Fixed 1A 1A 0.5% 2% 1% -11.5V to -12.5V MAP80-4001G5 -12V Fixed 1A 1A 0.5% 2% 1% -11.5V to -12.5V +12V Fixed 1A 1A 0.5% 2% 1% 11.5V to 12.5V MAP80-4002G5 -12V Fixed 1A 1A 0.5% 2% 1% -11.6V to -12.4V +12V Fixed 1A 1A 0.5% 2% 1% 11.6V to 12.4V MAP80-4003G5 -5V Fixed 1A 1A 0.5% 2% 1% -4.8V to -5.4V -15V Fixed 1A 1A 0.5% 2% 1% -14.4V to -15.5V MAP80-4004G5 -15V Fixed 1A 1A 0.5% 2% 1% -14.4V to -15.5V +15V Fixed 1A 1A 0.5% 2% 1% 14.4V to 15.5V MAP80-4010G5 -5V Fixed 1A 1A 0.5% 2% 1% -4.8V to -5.4V -12V Fixed 3A 3A 0.5% 2% 1% -11.5V to -12.5V 1 Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum. 2 Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 3 MAP80-1012 output currents are expressed as 12V/15V operation. MAP80-1024 output currents are expressed as 24V/28V operation. 4 Peak loads up to 90 Watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 90 Watts. 5 Output rated 65 W max for 50°C ambient, convection cooled. 6 Output rated 75 W max for 50°C ambient, convection cooled. 7 Non-G models use lead solder exemption and are not recommended for new designs.
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection BCD.00565_AD PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Input Voltage - AC Continuous input range 90 175 135
264 VAC
Input Frequency AC input 47 63 Hz Brown Out Protection Lowest AC input voltage that regulation is maintained with full rated loads. 90 VAC Hold-up Time Nominal AC input voltage (115VAC), full rated load. 20 ms Input Current 90 VAC (80 W load) 110VAC (80W load) 2.5
1.8 ARMS
Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Internally limited by thermistor, Vin = 264 VAC (one cycle), 25° C 45 APK Operating Frequency Switching frequency of power supply (varies with load) 22 120 kHz PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Efficiency Full load @ 115 VAC. Varies with distribution of loads among outputs. 73% typical Minimum Loads MAP80-1012 MAP80-1024 All multiple output models, main channel only 0.42 0.21 1.50 Amps Ripple and Noise Full load, 20 MHz bandwidth. See Model Selection Chart Output Power Continuous output power, all multiple output models. Peak output power (60s maximum, 10% duty cycle), all multiple output models. Watts Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on, V1, V2. 1 % Regulation Varies by output. Total regulation includes: line changes from 90-132 VAC or 175-264, changes in load starting at 20% load and changing to 100% load. See Model Selection Chart Transient Response Recovery time, to within 1% of initial set point due to a 50-100% load change, 4% max. deviation. (Main output of multiple output units). 500 μs Turn-on Delay Time required for initial output voltage stabilization. 1 5 Sec Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. 20 ms PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Overvoltage Protection Provided on the main output of multiple output units. MAP80-1012 MAP80-1024 5.5 17.5 6.8 V Overload Protection Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. Power Fail Warning 8 TTL compatible logic signal. Time before regulation dropout due to loss of input power at 110 VAC. 4 ms 8 Power Fail Warning is not available for MAP80-1024. The MAP80-1012 is an open collector output, capable of sinking 35 mA, maximum
4 MAP80 Series
tech.support@psbel.com PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Agency Approvals Approved to the latest edition of the following standards; UL/CSA60950-1 2nd, IEC60950-1 2nd and EN60950-1 2nd. Dielectric Withstand Voltage Input to Chassis Input to Output (tested by manufacturer only) 2121
4242 VDC
Electromagnetic Interference, Conducted FCC CFR title 47 Part 15 Sub-Part B - conducted & radiated. EN55022 / CISPR 22 conducted. EN55022 / CISPR 22 radiated. B B B Class Input Transient Protection EN61000-4-5 Level 3 Line to Line Line to Ground 2 kV Insulation Resistance Input to output 7 MΩ Leakage Current Per EN60950, 264 VAC 500 μA PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Altitude Operating Non-operating 10k 40k ASL Feet Operating Temperature9 Derate linearly above 50°C by 2.5% per °C to a maximum temperature of 70°C At 100% load: At 50% load: 0 50 70 °C Storage Temperature -40 85 °C Temperature Coefficient 0°C to 70°C (after 15 minute warm-up) ±0.02 ±0.03 %/°C Relative Humidity Non-condensing 5 95 %RH Shock Operating, peak acceleration 20 G Vibration Random vibration, 10Hz to 2kHz, 3 axis 6 GRMS 9 The use of an external cooling fan (100LFM (linear feet per minute), minimum) shall be determined at end use if the 25°C ambient is exceeded. PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Dimensions 182.9 x 106.7 x 45.7 7.2 x 4.2 x 1.8 mm in Weight 0.82 1.8 kg lb Cover (Option) Order the cover number 412-59585-G separately. For convection cooled applications, derate output power to 65 watts on all multiple output models and MAP80-1005. Derate MAP80- 1012 and MAP80-1024 to 75 watts. Dimensions: 182.9 x 106.7 x 50.0 7.20 x 4.20 x 1.97 mm in
Figure 1. Mechanical Drawing equipment used in hazardous environments, or nuclear control systems. date manufactured. Specifications are subject to change without notice.