MAP30 BEL | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 6
Technical content
The Bel Power Solutions MAP30/40/42 Series of power supplies combines low cost and universal input in a board-only power solution to meet commercial and industrial requirements. Full international safety, EMI and ESD compliance ensure worldwide acceptance. All units bear the CE Mark. Fixed frequency operation simplifies system level operation. The MAP30/40/42 Series is configured to the international standard 3 x 5 inch footprint. Input and output connections are made via popular single-row Molex connec tors. Single output models feature wide - range output adjustability to meet a wide variety of standard and user- specific output voltage requirements. Universal Input 85-264 VAC Input Transient & ESD Compliance to EN61000-4-2/-3/-4 Meets EN55022 Conducted and Radiated Limits Greater than 311,000 Hours MTBF Remote Sense (MAP30, MAP42) RoHS Compliant CE Marked to Low Voltage Directive
2 MAP30/40/42 Series
tech.support@psbel.com MODEL 9 OUTPUT VOLTAGE ADJUSTMENT RANGE MAX OUTPUT CURRENT PEAK OUTPUT CURRENT 1 LINE REGULATION LOAD REGULATION RIPPLE & NOISE 2 INITIAL SETTING ACCURACY MODEL 9 OUTPUT VOLTAGE ADJUSTMENT RANGE OUTPUT CURRENT PEAK OUTPUT CURRENT 4 LINE REGULATION LOAD REGULATION RIPPLE & NOISE 2 INITIAL SETTING ACCURACY MAXIMUM OUTPUT POWER MAP40-3000G 40 W 7 +12V Fixed 2A 3.5A 1% 3.5% 5 1% 11.5V to 12.5V -12V Fixed 0.3A 0.5A 1% 2% 6 1% -11.5V to -12.5V MAP40-3100G +5V 4.75V to 5.25V 3A 5A 0.2% 2% 1% 4.9V to 5.1V +12V Fixed 2A 3.5A 1% 3.5% 5 1% 11.5V to 12.5V 40 W 7 -12V Fixed 0.3A 0.5A 1% 2% 1% -11.4V to -12.6V MAP40-3101G +5V 4.75V to 5.25V 3A 5A 0.2% 2% 1% 4.9V to 5.1V 40 W 7 +24V Fixed 1A 1.5A 1% 3.5% 5 1% 23.0V to 25.0V -12V Fixed 0.3A 0.5A 1% 2% 1% -11.5V to -12.5V MAP40-3105G 40 W 7 +12V Fixed 2A 3.5A 1% 3.5% 5 1% 11.5V to 12.5V -5V Fixed 0.5A 1A 1% 2% 1% -4.75V to -5.25V MAP40-3500G 40 W 7 +12V Fixed 1A 3.5A 1% 3.5% 5 1% 11.5V to 12.5V -12V Fixed 0.3A 0.5A 1% 2% 1% -11.4V to -12.6V MAP40-3003G 40 W 7 +15V Fixed 1.5A 3A 1% 3.5% 5 1% 14.7V to 15.3V -15V Fixed 0.2A 0.5A 1% 2% 6 1% -14.3V to -15.7V 1 Peak ratings may be used as maximum output current with 100 Linear Feet per Minute (LFM) forced air cooling. 2 Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 3 MAP42-1012G output currents are expressed as 12V/15V operation. MAP42-1024G output currents are expressed as 24V/28V operation. 4 Peak loads for 30 seconds or less are acceptable, (10% duty cycle max.). 5 Quasi regulated output. See Regulation Curves for more information. 6 Requires a minimum load of 0.5A on V1 or 0.3A on V2. 7 Needs 170 LFM forced air cooling for use at 50°C ambient. 8 Needs 200 LFM forced air cooling for use at 50°C ambient. 9 Non-G models use lead solder exemption and are not recommended for new designs. Xxx Model highlighted in yellow is not recommended for new designs.
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection BCD.00563_AC PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Input Voltage - AC Continuous input range MAP42 MAP30, MAP40 90 264
264 VAC
Input Frequency AC input 47 63 Hz Brown Out Protection Lowest AC input voltage that regulation is maintained with full rated loads. 85 VAC Hold-up Time Nominal AC Input Voltage (115VAC), full rated load. 15 ms Input Current 90 VAC (40W load). 1.2 ARMS Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Internally limited by thermistor, Vin = 264 VAC (one cycle), 25° C 38 APK Operating Frequency Switching frequency of power supply (fixed frequency). 23 25 30 kHz PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Efficiency Full load @120 VAC 70% typical Minimum Loads Single output models; MAP30, MAP42. All multiple output models, see regulation graphs. 0.0 Amps Ripple and Noise Full load, 20 MHz bandwidth. See Model Selection Chart. Output Power Multiple output models with convection cooling. 40 Watts Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on, V1. 1 % Regulation Varies by output, total regulation includes: Line changes from 90-
132 VAC or 175-264, changes in load starting at 20% load and
changing to 100% load. See regulation graphs. Transient Response Recovery time, to within 1% of initial set point due to a 50-100% load change, 4% max. deviation. (Main output only of multiple output units). 500 μs Turn-on Delay Time required for initial output voltage stabilization. 1 2 Sec Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. 20 ms PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Overvoltage Protection MAP30-1005G, MAP42-1005 MAP42-1012G MAP42-1024G Main output only of multiple output units. 5.8 20.0 32.0 5.8 6.8 22.0 37.0 6.8 V Overload Protection Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. 130 % Remote Sense Total cable drop, single output models only. 250 mV 8 Power Fail Warning is not available for MAP80-1024G. The MAP80-1012G is an open collector output, capable of sinking 35 mA, maximum.
4 MAP30/40/42 Series
tech.support@psbel.com PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Agency Approvals Approved to the latest edition of the following standards; UL/CSA60950-1 2nd, IEC60950-1 2nd and EN60950-1 2nd. Dielectric Withstand Voltage Input to Chassis Input to Output (tested by manufacturer only) 2121
4242 VDC
FCC CFR title 47 part 15 sub-part B - conducted EN55022 / CISPR 22 conducted (Note 1) EN55022 / CISPR 22 radiated (Note 2) B B B Class Input Transient Protection EN61000-4-5 Level 3 Line to Line Line to Ground 2 kV Insulation Resistance Input to output 7 MΩ Leakage Current Per EN60950, 264VAC MAP42, MAP40-3100G/3001G/3105G/3500G 500 μA MAP30-1005G, MAP40-3000G, MAP40-3003G 750 PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Altitude Operating Non-operating 10k 40k ASL Ft. Operating Temperature Derate linearly above 50°C by 2.5% per °C At 100% load: to a maximum temperature of 70°C At 50% load: 0 50 70 °C Storage Temperature -40 85 °C Temperature Coefficient 0°C to 70°C (after 15 minute warm-up) ±0.02 ±0.03 %/°C Relative Humidity Non-condensing 5 95 %RH Shock Operating, peak acceleration 20 G Vibration Random vibration, 10Hz to 2kHz, 3 axis 6 GRMS 12V OUTPUT CURRENT Figure1. MAP40-3500G Typical Quasi Regulation Performance For +12V Output 14.25 13.75 13.25 12.75 12.25 11.75 11.25 V @ 5.0 Amps V @ 3.0 Amps V @ 1.0 Amps V @ 0 Amps 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.9 1.0 0.8
6 MAP30/40/42 Series
Table 1. MAP30/40/42 Series Height Figure 1. Mechanical Drawing equipment used in hazardous environments, or nuclear control systems. date manufactured. Specifications are subject to change without notice.