MAP30 POWER-ONE | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

Power-One’s MAP30/40/42 series of power supplies combines low cost and universal input in a board-only power solution to meet commercial and industrial requirements. Full international safety, EMI, and ESD compliance ensure world-wide acceptance. All units bear the CE Mark. Fixed frequency operation simplifies system level operation. The MAP30/40/42 series is configured to the international standard 3.00" x 5.00" footprint. Input and output connections are made via popular single row Molex connectors. Single output models feature wide-range output adjustability to meet a wide variety of standard and user specific output voltage requirements.FEATURES

  • Universal Input 85-264 VAC
  • CE Marked to Low Voltage Directive
  • Input Transient & ESD Compliance to EN61000-4-2/-3/-4
  • Meets EN55022 Conducted and Radiated Limits
  • Greater than 311,000 Hours MTBF
  • Remote Sense (MAP30, MAP42) SINGLE OUTPUT MODEL SELECTION CHART MODEL OUTPUT ADJUSTMENT MAXIMUM OUTPUT PEAK OUTPUT LINE LOAD RIPPLE & NOISE INITIAL SETTING VOLTAGE RANGE CURRENT CURRENT (NOTE 2) REGULATION REGULATION %p-p (NOTE 1) ACCURACY NOTES: 1) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth. 2) Peak ratings may be used as maximum output current with 100 Linear Feet per Minute (LFM) forced air cooling. 3) MAP42-1012 output currents are expressed as 12V/15V operation. MAP42-1024 output currents are expressed as 24V/28V operation. MULTIPLE OUTPUT MODEL SELECTION CHART – 40W CONTINUOUS OUTPUT POWER MODEL OUTPUT ADJUSTMENT OUTPUT PEAK OUTPUT LINE LOAD RIPPLE & NOISE INITIAL SETTING VOLTAGE RANGE CURRENT CURRENT (NOTE 1) REGULATION REGULATION %p-p (NOTE 2) ACCURACY MAP40-3000 +12V Fixed 2A 3.5A 1% 3.5% (Note 3) 1% 11.5V to 12.5V -12V Fixed 0.3A 0.5A 1% 2% (Note 4) 1% -11.4V to -12.6V MAP40-3100 +12V Fixed 2A 3.5A 1% 3.5% (Note 3) 1% 11.5V to 12.5V -12V Fixed 0.3A 0.5A 1% 2% 1% -11.4V to -12.6V MAP40-3101 +24V Fixed 1A 1.5A 1% 3.5% (Note 3) 1% 23.0V to 25.0V -12V Fixed 0.3A 0.5A 1% 2% 1% -11.5V to -12.5V MAP40-3105 +12 Fixed 2A 3.5A 1% 3.5% (Note 3) 1% 11.5V to 12.5V -5V Fixed 0.5A 1.0A 1% 2% 1% -4.75V to -5.25V MAP40-3500 +12V Fixed 1A 3.5A 1% 3.5% (Note 3) 1% 11.5V to 12.5V -12V Fixed 0.3A 0.5A 1% 2% 1% -11.4V to -12.6V MAP40-3003 +15V Fixed 1.5A 3A 1% 3.5% (Note 3) 1% 14.7V to 15.3V -15V Fixed 0.2A 0.5A 1% 2% (Note 4) 1% -14.3V to -15.7V NOTES : 1) Peak loads for 30 seconds or less are acceptable, (10% duty cycle max.). 2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth. 3) Quasi regulated output. See Regulation Curves for more information. 4) Requires a minimum load of 0.5A on V1 or 0.3A on V2. Rev. 10/2000 NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc. TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice.

PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Input Voltage - AC Continuous input range. MAP42 85 264 VAC MAP30, MAP40 90 264 Input Frequency AC input. 47 63 Hz Brown Out Protection Lowest AC input voltage that regulation is maintained with full rated loads. 85 VAC Hold-up Time Nominal AC Input Voltage (115VAC), full rated load. 15 mS Input Current 90 VAC (40W load). 1.2 A RMS Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Internally limited by thermistor. Vin = 264VAC (one cycle). 25° C. 38 A PK Operating Frequency Switching frequency of power supply (fixed frequency). 23 25 30 kHz OUTPUT SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Efficiency Full load, 120VAC. 70 % Minimum Loads Single output models; MAP30, MAP42. 0.0 Amps All multiple output models, see regulation graphs. Ripple and Noise Full load, 20MHz bandwidth. See Model Selection Chart. Output Power Multiple output models with convection cooling. 40 Watts Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on, V1. 1 % Regulation Varies by output, total regulation includes: Line changes from 90-132 VAC or 175-264, changes in load starting at 20% load and changing See regulation graphs. to 100% load. Transient Response Recovery time, to within 1% of initial set point due to a 50-100% 500 µS load change, 4% max. deviation. (Main output only of multiple output units). Turn-on Delay Time required for initial output voltage stabilization. 1 2 Sec Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. 20 mS INTERFACE SIGNALS AND INTERNAL PROTECTION PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS MAP30-1005, MAP42-1005 5.8 6.8 Overvoltage MAP42-1012 20.0 22.0 VProtection MAP42-1024 32.0 37.0 Main output only of multiple output units. 5.8 6.8 Overload Fully protected against output overload and short circuit. Automatic 130 % Protection recovery upon removal of overload condition. Remote Sense Total cable drop, single output models only. 250 mV SAFETY, REGULATORY, AND EMI SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Agency Approvals UL1950. CSA 22.2 No. 234/950. Approved. EN60950 (TUV). Dielectric Withstand Input to output. 2600 VDC Voltage Electromagnetic FCC CFR title 47 part 15 sub-part B - conducted. B Interference EN55022 / CISPR 22 conducted (Note 1). B Class EN55022 / CISPR 22 radiated (Note 2). B Input Transient EN61000-4-5 Level 3 Line to Line 1 kV Protection Line to Ground 2 Insulation Resistance Input to output. 7 M Ω Leakage Current Per EN60950, 264VAC MAP42, MAP40-3100, 3001, 3105, 3500 500 µAMAP30-1005, MAP40-3000, MAP40-3003 750 NOTES: 1) MAP30-1005, MAP40-3000, MAP40-3003 meet Class A. 2) MAP40-3000, MAP40-3003, MAP3500 meet Class A. MAP30/40/42 SERIES

ENVIRONMENTAL SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Altitude Operating. 10k ASL Ft. Non-operating. 40k ASL Ft. Operating Temperature Derate linearly above 50°C by 2.5% At 100% load: 0 50 °C per °C to a maximum temperature of 70°C. At 50% load: 0 70 °C Storage Temperature -40 85 °C Temperature Coefficient 0°C to 70°C (after 15 minute warm-up). ±0.02 ±0.03 %/°C Relative Humidity Non-condensing. 5 95 %RH Shock Operating, peak acceleration. 20 G Vibration Random vibration, 10Hz to 2kHz, 3 axis. 6 G RMS 14.25 13.75 13.25 12.75 12.25 11.75 11.25 13.5 13.0 12.5 12.0 11.5 11.0 17.0 16.5 16.0 15.5 15.0 14.5 14.0 13.5 12V OUTPUT VOLTAGE12V OUTPUT VOLTAGE15V OUTPUT VOLTAGE MAP40-3500 TYPICAL QUASI REGULATION PERFORMANCE FOR +12V OUTPUT MAP40-3000/3100/3105 TYPICAL QUASI REGULATION PERFORMANCE FOR +12V OUTPUT MAP40-3003 TYPICAL QUASI REGULATION PERFORMANCE FOR +15V OUTPUT +5V @ 5.0 Amps +5V @ 3.0 Amps +5V @ 1.0 Amps +5V @ 0 Amps +5V @ 3.0 Amps +5V @ 1.8 Amps +5V @ 0.6 Amps +5V @ 0 Amps +5V @ 3.0 Amps +5V @ 1.8 Amps +5V @ 0.6 Amps +5V @ 0 Amps 12V OUTPUT CURRENT 12V OUTPUT CURRENT 15V OUTPUT CURRENT MAP30/40/42 SERIES

5.00" (127.0mm) 0.23" (5.7mm) 4.55" (115.6mm) 2.55" (64.8mm) 3.00" (76.2mm) 0.25" (6.4mm) see table 0.16" (4.0mm) Diameter Diameter Mounting Holes (4 Places) COMPONENT LEAD LENGTH 0.10" (2.5mm) MAX Multiple Output Models Model Height GND GND +Sense -Sense PIN 6 PIN 1 N/C GND GND +Sense -Sense PIN 7 PIN 1 MAP30 J2 J1/J2 MATES WITH MOLEX (SERIES 2139 or SERIES 41695) .156" (4mm) CENTER CRIMP TERMINAL HOUSING OR EQUIVALENT Single Output Models Model Height GND GND PIN 6 PIN 1 NEUTRAL PIN 1 PIN 2 (REMOVED) LINE PIN 3 SAFETY EARTH GROUND (0.250" x 0.032" FASTON) MAP40 J2 MAP42 J2 OVERALL SIZE: 5.00" x 3.00" x (see table) (127.0mm x 76.2mm x see table) WEIGHT: 0.6 LBS (0.26 kg) MAP30/40/42 SERIES HEIGHT MAP30/40/42 SERIES