Bel Power Solutions MAP55 Series of power supplies provides reliable, tightly -regulated DC power for commercial and industrial systems. Wide-range AC input and full international safety, EMI, and ESD compliance ensure worldwide acceptance. All units bear the CE Mark. The MAP55 utilizes a thermally eff icient U -channel chassis design. Other mechanical design innova tions include metric and SAE mounting inserts on each mounting surface to provide integration flexibility. Dual -mode connectors provide traditional terminal block connections or popular single row Molex connector mating. Single-output models feature wide-range output adjustability to meet a wide variety of standard and user -specific output voltage requirements. RoHS Compliant Wide Range Input for 110/220 VAC Applications Meets EN55022, Conducted Class B Limits Greater than 225000 Hours MTBF Metric and SAE Mounting Inserts
2 MAP55 Series
tech.support@psbel.com MODEL8 OUTPUT VOLTAGE ADJUSTMENT RANGE MAX OUTPUT CURRENT PEAK OUTPUT CURRENT1 LINE REGULATION LOAD REGULATION RIPPLE NOISE2 INITIAL SETTING ACCURACY MODEL8 OUTPUT VOLTAGE ADJUSTMENT RANGE OUTPUT CURRENT PEAK OUTPUT CURRENT4 LINE REGULATION LOAD REGULATION RIPPLE NOISE2 INITIAL SETTING ACCURACY MAP55-4000G7 +12V Fixed 3A 5A 0.2% 2% 1% 11.6V to 12.4V -5V Fixed 0.5A 1A5 0.5% 2% 1% -4.8V to -5.2V -12V Fixed 0.5A 1A5 0.5% 2% 1% -11.6V to -12.4V MAP55-4001G7 -12V Fixed 0.5A 1A5 0.5% 2% 1% -11.6V to -12.4V +12V Fixed 0.5A 1A5 0.5% 2% 1% 11.6V to 12.4V MAP55-4002G7 +12V Fixed 3A 5A 0.2% 2% 1% 11.6V to 12.4V -12V Fixed 0.5A 1A5 0.5% 2% 1% -11.6V to -12.4V +12V Fixed 0.5A 1A5 0.5% 2% 1% 11.6V to 12.4V MAP55-4003G7 -5V Fixed 0.5A 1A5 0.5% 2% 1% -4.8V to -5.2V -15V Fixed 0.5A 1A5 0.5% 2% 1% -14.4V to -15.6V MAP55-4004G7 -15V Fixed 0.5A 1A5 0.5% 2% 1% -14.5V to -15.5V +15V Fixed 0.5A 1A5 0.5% 2% 1% 14.5V to 15.5V 1 Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum. 2 Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 3 MAP55-1012 output currents are expressed as 12V/15V operation. MAP55-1024 output currents are expressed as 24V/28V operation. 4 Peak loads up to 65 watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 65 watts. 5 Maximum load on V3 or V4 could be 1 amp continuous if output V4 or V3 is unloaded. 6 Maximum 60 W with 150LFM (Linear Feet per Minute) air cooling or maximum 50 W with convection cooling. 7 Maximum 55 W with 200LFM (Linear Feet per Minute) air cooling or maximum total output power 45 W at 40°C ambient operating temperature for models with no cover and 40 W for models with cover / convection cooling. 8 Non-G models use lead solder exemption.
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection BCD.00564_AD PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Input Voltage - AC Continuous input range 90 175 132
264 VAC
Input Frequency AC input 47 63 Hz Brown Out Protection Lowest AC input voltage that regulation is maintained with full rated loads 90 VAC Hold-up Time Nominal AC Input Voltage (115VAC), full rated load 20 ms Input Current 90 VAC (55 W load) 1.6 ARMS Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Internally limited by thermistor, Vin = 264 VAC (one cycle), 25°C 38 APK Operating Frequency Switching frequency of power supply (varies with load) 22 180 kHz PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Efficiency Full load @ 115 VAC. Varies with distribution of loads among outputs. 73% typical Minimum Loads MAP55-1012 MAP55-1024 MAP40-1005 and all multiple output models, main channel only 0.21 0.11 0.50 Amps Ripple and Noise Full load, 20 MHz bandwidth. See Model Selection Chart Output Power Continuous output power, all multiple output models. Peak output power (60 s maximum, 10% duty cycle), all multiple output models. Watts Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on, V1, V2. 1 % Regulation Varies by output. Total regulation includes: line changes from 90-
132 VAC or 175-264 VAC, changes in load starting at 20% load and
changing to 100% load. See Model Selection Chart Transient Response Recovery time, to within 1% of initial set point due to a 50-100% load change, 4% max. deviation. (Main output of multiple output units.) 500 μs Turn-on Delay Time required for initial output voltage stabilization. 1 4 Sec Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. (Nominal rise time for MAP55-1024 is 36 msec.) 7 ms PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Overvoltage Protection MAP40-1005 MAP55-1012 MAP55-1024 Main output only of multiple output units. 5.5 17.5 32.0 5.6 6.8 19.7 36.0 6.8 V Overload Protection Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.
4 MAP55 Series
tech.support@psbel.com PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Agency Approvals Approved to the latest edition of the following standards; UL/CSA60950-1 2nd, IEC60950-1 2nd and EN60950-1 2nd. Dielectric Withstand Voltage Input to Chassis Input to Output (tested by manufacturer only) 2121
4242 VDC
Electromagnetic Interference, Conducted FCC CFR title 47 Part 15 Sub-Part B - conducted & radiated. EN55022 / CISPR 22 conducted. EN55022 / CISPR 22 radiated. B B A Class Insulation Resistance Input to output 7 MΩ Leakage Current Per EN60950, 264 VAC 500 μA PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Altitude Operating Non-operating 10k 40k Feet Operating Temperature Derate linearly above 50°C by 2.5% per °C to a maximum temperature of 70°C (with 200LFM) At 100% load: At 50% load: 0 50 70 °C Storage Temperature -40 85 °C Temperature Coefficient 0°C to 70°C (after 15 minute warm-up) ±0.02 ±0.03 %/°C Relative Humidity Non-condensing 5 95 %RH Shock Operating, peak acceleration 20 G Vibration Random vibration, 10Hz to 2kHz, 3 axis 6 GRMS PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Dimensions 152.4 x 83.1 x 40.6 6.00 x 3.27x 1.6 mm in Weight 0.55 1.1 kg lb Cover (Option) Order the cover number 412-59584-G separately. For convection cooled applications, derate output power to 40 watts on multiple output units, 50 watts on MAP55-1012 and MAP55-1024 and 40 watts on MAP40-1005. Dimensions: 152.4 x 83.1 x 45.0 6.00 x 3.27 x 1.77 mm in CONNECTOR CONDITIONS / DESCRIPTION Input & Output Connectors 6-32 screw wire clamps on 0.312" (7.9 mm) centers 0.045" (1.1 mm) square pins on 0.156" (3.4 mm) centers Matting Connectors Molex Series 2139, 6442, or 41695 Chassis 0.090" (2.3 mm) aluminum alloy, with clear finish
Figure 1. Mechanical Drawing equipment used in hazardous environments, or nuclear control systems. the date manufactured. Specifications are subject to change without notice.