MAP140 BEL | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

Bel Power Solutions MAP140 Series provides a full range of options and up to 30 watts more power than comparable products in this industry-standard footprint. With a universal input from 85 to 264 VAC and power densities up to 2.6 watts/inch 3, the MAP140 meets the most rigorous requirements of commercial, industrial, and datacom systems. Rated for use in convection and forced-air cooled (200 LFM) applications, the MAP140 delivers dependable power with a Mean Time Between Failures (MTBF) in excess of 180,000 hours. In addition to UL, CSA, and NEMKO regulatory compliance, the MAP140 displays the CE Mark.  RoHS Lead-Solder-Exemption Compliant  Universal Input 85-264 VAC  Input Transient & ESD Compliance to EN61000-4-2/-3/-4  CE marked to Low Voltage Directive  Industry-Standard Footprint: 7.0 x 4.3 x 1.8 inch (177.8 x 109.2 x 45.7 mm)  Remote Sense and Overvoltage Protection  Power Fail Signal Standard on MAP140-3000P, Optional on MAP140- 1012 and MAP140-1024G  Optional Overtemperature Protection, L-bracket and Cover

2 MAP140 Series

tech.support@psbel.com MODEL5 OUTPUT VOLTAGE ADJUSTMENT RANGE CONVECTION COOLED CURRENT FORCED AIR CURRENT 1 LINE REGULATION LOAD REGULATION RIPPLE NOISE 2 INITIAL SETTING ACCURACY MODEL5 OUTPUT VOLTAGE ADJUSTMENT RANGE OUTPUT CURRENT 4 PEAK OUTPUT CURRENT 4 LINE REGULATION LOAD REGULATION RIPPLE & NOISE 2 INITIAL SETTING ACCURACY MAP140-3000P* +5V 4.75V to 5.25V 16A/25A PK 20A/25A PK 0.2% 1% 1% 5.09V to 5.11V +12V Fixed 4A/9A PK 4A/9A PK 0.1% 2% 1% 11.97V to 12.03V -12V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 2% 1% -11.4V to - 12.6V 1 With minimum 200 LFM forced air cooling. 2 Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth. 3 MAP140-1012 output currents are expressed as 12V/15V operation. MAP140-1024G output currents are expressed as 24V/28V operation. 4 Peak loads up to 140 Watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 140 watts. 5 Non-G models use lead solder exemption and are not recommended for new designs. Oooooo Model numbers highlighted in yellow are not recommended for new designs. * Obsolete

+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection BCD.00574_AC PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Input Voltage - AC Continuous input range 85 264 VAC Input Frequency AC input 47 63 Hz Brown Out Protection Lowest AC input voltage that regulation is maintained with full rated loads. 85 VAC Hold-up Time Nominal AC input voltage (110VAC), full rated load. 110 watt load: 20 ms 140 watt load: 16 Input Current 85 VAC (140 W load) 110 VAC (140 W load) 2.5

2.0 ARMS

Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Internally limited by thermistor, Vin = 264 VAC (one cycle), 25° C 41 APK Operating Frequency Switching frequency of main transformer 22 kHz PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Efficiency Full load @110 VAC. Varies with distribution of loads among outputs 70% typical Minimum Loads Single output models MAP140-3000P, total output current of V1 + V2 6

2 Amps

Ripple and Noise Full load, 20 MHz bandwidth. See Model Selection Chart Output Power Single output models See Model Selection Chart MAP140-3000P with convection cooling 80 Watts MAP140-3000P with 200 LFM forced air cooling 140 Watts Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on / turn-off. 1 % Regulation Varies by output, regulation includes: line changes from 90-132 VAC or 175-264, changes in load starting at 20% load and changing to 100% load. See Model Selection Chart Transient Response Recovery time, to within 1% of initial set point due to a 50-100% load change, 4% max. deviation. (Main output only on multiple output units). 500 μs Turn-on Delay Time required for initial output voltage stabilization. MAP140-3000P Sec Single output models 2 Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. 20 ms 6 Minimum load is required only to meet the regulation limits of V3.

4 MAP140 Series

tech.support@psbel.com PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Overvoltage Protection Provided on single output models and V1 of MAP140-3000P. MAP140-3000P, V1 6.1 7.2 V MAP140-1012 17.3 20.2 MAP140-1024G 32.2 37.8 MAP140-1048 55.2 64.8 Overload Protection Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. Remote Sense Voltage drop compensated for at the load. 250 mV Power Fail Warning TTL compatible logic signal. Time before regulation dropout due to loss of input power at 140 watts, 110 VAC. Standard on MAP140- 3000P and optional on MAP140-1012. 2.3 ms Overtemperature Protection Optional signal provides system shutdown due to excessive internal temperature. See options. PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Agency Approvals Approved to the latest edition of the following standards; UL/CSA60950-1 2nd, IEC60950-1 2nd and EN60950-1 2nd. Dielectric Withstand Voltage Input to Chassis Input to Output (tested by manufacturer only) 2121

4242 VDC

Electromagnetic Interference FCC CFR title 47 Part 15 Sub-Part B - conducted & radiated B Class Conducted EN55022 / CISPR 22 conducted B Class ESD Susceptibility Per EN61000-4-2, level 4 8 kV Radiated Susceptibility Per EN61000-4-3, level 3 10 V/M EFT/Burst Per EN61000-4-4, level 3 ±2 kV Input Transient Protection EN61000-4-5 Class 3 Line to Line Line to Ground kV Insulation Resistance Input to output 10 MΩ Leakage Current Per EN60950, 264 VAC 110 VAC 264 VAC 0.5 1.5 mA PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Altitude Operating Non-operating 10k 40k ASL Feet Operating Temperature9 Derate linearly above 50°C by 2.5% per °C At 100% load: At 50% load: 0 50 70 °C Storage Temperature -40 85 °C Temperature Coefficient 0°C to 70°C (after 15 minute warm-up) ±0.02 ±0.05 %/°C Relative Humidity Non-condensing 95 %RH Shock Operating, peak acceleration 20 G Vibration Random vibration, 10Hz to 2kHz, 3 axis 6 GRMS

Add ‘C’ suffix to model number (Please check with factory for availability). For convection cooled applications, derate output power to 75 watts, maximum. Add ‘P’ suffix to model number. Provides 2.3mS warning time before main output drops 5%. Warning time increases at reduced load levels. Option available only on MAP140-1012 and MAP140-1024G. Power fail is standard on MAP140-3000P. Thermal Shutdown Add ‘T’ suffix to model number. Initiates shut-down in the event of an overtemperature condition. Automatic recovery. Where available, Power Fail signal is initiated prior to shutdown. Figure 1. Mechanical Drawing equipment used in hazardous environments, or nuclear control systems. the date manufactured. Specifications are subject to change without notice.