MAP130 POWER-ONE | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

Power-One’s MAP130 series of single and multiple output power supplies provide fully regulated outputs with high-peak current capabilities in a compact 4.50" x 8.50" x 2.00" U-channel chassis. Other standard features include autoselect AC input, EMI level B filtering, power fail, thermal shutdown (with warning), remote sense, and metric and SAE mounting inserts. This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 degrees C. All products are approved to the latest international regulatory standards, and display the CE Mark.

FEATURES

  • Automatic 115/230 Input Voltage Selection
  • All Outputs Fully Regulated
  • Remote Sense, Overvoltage Protection, and Overtemperature Protection
  • Power Fail Signal Included
  • Greater than 100,000 Hour MTBF
  • Optional Cover
  • Metric and SAE Mounting Inserts SINGLE OUTPUT MODEL SELECTION CHART MODEL OUTPUT ADJUSTMENT CONTINUOUS PEAK LINE LOAD TYPICAL RIPPLE & INITIAL SETTING VOLTAGE RANGE CURRENT CURRENT (NOTE 3) REGULATION REGULATION NOISE %p-p (NOTE 1) ACCURACY NOTES: 1) Typical peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth. 2) MAP130-1012 output currents are expressed as 12V/15V operation. MAP130-1024 output currents are expressed as 24V/28V operat ion. 3) Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum. MULTIPLE OUTPUT MODEL SELECTION CHART – 130W CONTINUOUS OUTPUT POWER MODEL OUTPUT ADJUSTMENT OUTPUT PEAK CURRENT LINE LOAD TYPICAL RIPPLE & INITIAL SETTING VOLTAGE RANGE CURRENT (NOTE 1) REGULATION REGULATION NOISE %p-p (NOTE 2) ACCURACY -5V Fixed 1A 1A 0.5% 2% 1% -4.8V to -5.2V -12V Fixed 1A 1A 0.5% 2% 1% -11.6V to -12.4V -12V Fixed 1A 1A 0.5% 2% 1% -11.6V to -12.4V +12V Fixed 1A 1A 0.5% 2% 1% -11.6V to -12.4V -12V Fixed 1A 1A 0.5% 2% 1% -11.6V to -12.4V +12V Fixed 1A 1A 0.5% 2% 1% 11.6V to 12.4V MAP130 SERIES Rev. 04/2000 NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems , equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc. TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change dependin g on the date manufactured. Specifications are subject to change without notice.

MULTIPLE OUTPUT MODEL SELECTION CHART (CONT.) – 130W CONTINUOUS OUTPUT POWER MODEL OUTPUT ADJUSTMENT OUTPUT PEAK CURRENT LINE LOAD TYPICAL RIPPLE & INITIAL SETTING VOLTAGE RANGE CURRENT (NOTE 1) REGULATION REGULATION NOISE %p-p (NOTE 2) ACCURACY +5V 4.75V to 5.50V 20A 30A 1% 1% 1% 5.1V to 5.2V MAP130-4003 +15V 14.0V to 16.0V 4A 8A 1% 2% 1% 15.0V to 15.1V -5V Fixed 1A 1A 2% 2% 1% 4.9V to 5.1V -15V Fixed 1A 1A 2% 2% 1% 14.7V to 15.3V -15V Fixed 1A 1A 0.5% 2% 1% -14.5V to -15.5V +15V Fixed 1A 1A 0.5% 2% 1% 14.5V to 15.5V -5V Fixed 1A 1A 0.5% 2% 1% -4.8V to -5.2V -12V Fixed 3A 3A 0.5% 2% 1% -11.6V to -12.4V -12V Fixed 1A 1A 0.5% 2% 1% -11.6V to -12.4V -5V Fixed 3A 3A 0.5% 2% 1% -4.8V to -5.2V NOTES: 1) Peak loads up to 165 Watts, (total of all outputs), for 60 seconds or less are acceptable, (10% duty cycle max.). 2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth. INPUT SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Input Voltage- AC Auto-ranging. Low Range 90 115 132 VAC High Range 175 230 264 Input Frequency AC Input. 47 63 Hz Brown out Protection Lowest AC input voltage that regulation is maintained with full rated loads. 90 VAC Hold-up Time Nominal AC input voltage (115 VAC). 130W load: 40 mS Input Current 90 VAC, 130W load. 3.3 A RMS Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Internally limited by thermistor. Vin = 264 VAC (one cycle). 25° C. 38 A PK Operating Frequency Switching frequency of main transformer (variable). Range: 16 120 kHz OUTPUT SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Efficiency Full Load, 115VAC. Varies with distribution of loads among outputs. 71 80 % Minimum Loads MAP130-1012. 1.25 MAP130-1024. 0.63 Amps MAP130-1005 and all multiple output models, main channel only. 3.00 Ripple and Noise Full load, 20MHz bandwidth. See Model Selection Chart Output Power Continuous output power, all multiple output models. 130 WattsPeak output power (60s maximum, 10% duty cycle), all multiple output models. 165 Overshoot /Undershoot Output voltage overshoot/undershoot at turn-on / turn-off 1 % Regulation Varies by output, Total regulation includes: line changes from 90-132 VAC See Model Selection Chartor 175-264, changes in load starting at 20% load and changing to 100% load. Transient Response Recovery time to within 1% of initial set point due to a 50-100% load change, 500 µS4% max. deviation. (Main output only on multi-output units) Turn-on Delay Time required for initial output voltage stabilization. 2 Sec Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. 20 mS MAP130 SERIES

INTERFACE SIGNALS AND INTERNAL PROTECTION PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Overvoltage Protection Provided on single output units and only MAP130-1012 17.0 22.0 All other models. 5.5 6.8 Overcurrent Protection All models have inherent short circuit protection. Units will automatically restart at the removal of th e fault. Remote Sense Total voltage compensation for main output cable losses. 250 mV Logic LO (denotes power fail detected). 0.7 V Power Fail Warning Logic HI with internal pull-up to output. 10 k Ω (Note 1) Power Fail trip point, maximum load, decreasing line. 86 94 VAC Time before regulation dropout, at full load, due to loss of input power. 5 mS Overtemperature Warning Warning prior to system shutdown due to excessive internal temperatures. 20 mS(Note 2) Shifts Power Fail signal to a logic LO state. NOTES: 1) Power Fail not available on MAP130-1012 and MAP130-1024. 2) MAP130-1012 and MAP130-1024 have overtemperature protection, but do not have the warning feature. SAFETY, REGULATORY, AND EMI SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Agency Approvals UL1950. CSA 22.2 No. 234/950. Approved EN60950 (TÜV). Dielectric Withstand Voltage Input to Output, 1 second. 2600 VDC Electromagnetic FCC CFR title 47 Part 15 Sub-Part B - Conducted B Interference, EN55022 / CISPR 22 Conducted B Class EN55022 / CISPR 22 Radiated (Note 1) B ESD Susceptibility Per EN61000-4-2, level 4 8 kV Radiated Susceptibility Per EN61000-4-3, level 3 10 V/M EFT/Burst Per EN61000-4-4, level 3 (Note 2) ±2 kV Input Transient Protection Per EN61000-4-5 class 3 Line to Line 1 kVLine to Ground 2 Insulation Resistance Input to output 7 M Ω Leakage Current Per EN60950 (264 VAC) 700 µA NOTES: 1) MAP130-1005 meets Class A, radiated. 2) MAP130-1005, MAP130-4003, and MAP130-4010, meet level 2, ±1kV. ENVIRONMENTAL SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Altitude Operating 10K FeetNon-Operating 40K Operating Temperature At 100% load: 0 50 °C Derate linearly above 50°C by 2.5% per °C At 50% load: 70 °C Storage Temperature -40 85 °C Temperature Coefficient 0°C to 70°C (after 15 minute warm-up period) ±0.02 ±0.05 %/°C Relative Humidity Non-Condensing 5 95 %RH Shock Operating, peak acceleration 20 G PK Vibration Random vibration, 10Hz to 2kHz, 3 axis 6 G RMS OPTIONS DESCRIPTION NOTES DIMENSIONS Cover Add ‘C’ suffix to model number or order part number 412-59586 separately. For convection cooled applications with covers, derate output power as follows: 8.50" x 4.50" x 2.40" Derate all multiple output models and MAP130-1005 to 120 watts. (215.9mm x 114.3mm x 61.0mm) Derate MAP130-1012 and MAP130-1024 to 140 watts. MAP130 SERIES

0.74" (18.7mm) 3.030" (77.0mm) 4.50" (114.3mm) TB1 ADJ. 2.00" (50.8mm) T3.5A/250V~ ADJ. TB2 NC PF DC OUTPUT (MATES WITH 16 CIRCUIT MOLEX CONNECTOR) TB2 V1 COM V3 V4 V2V1 PIN 1TB1 GND N L PIN 1 AC INPUT (MATES WITH 5 CIRCUIT MOLEX CONNECTOR) MAP130 SERIES .. .. .. .. 6-32 UNC — 2B THREAD M4 x 0.7 — 6H THREAD 0.17" (4.3mm) DIA THRU UNIVERSAL MOUNTING INSERT (8 PLACES) 0.74" (18.7mm) 8..000" (203.2mm) 8..50" (215.9mm) 0.25" (6.35mm) 1.04" (26.3mm) 1.27" (32.1mm) 1.27" (32.1mm) 2.426" (61.6mm) 1.970" (50.0mm) 1.04" (26.3mm) NO CONNECTION + SENSE, V1 SENSE, V1- POWER FAIL WARNING MAP130 SERIES WEIGHT: 2.5 LBS (1.13 kg) INPUT & OUTPUT CONNECTIONS: 6-32 SCREW WIRE CLAMPS ON 0.312" (7.9mm) CENTERS, 0.045" (1.1mm) SQUARE PINS ON 0.156" (3.96mm) CENTERS, MATES WITH MOLEX SERIES 2139, 6442, & 41695 POWER FAIL CONNECTIONS, J2: 0.035" (0.89mm) SQUARE PINS ON 0.100" (2.54mm) CENTERS, MATES WITH MOLEX SERIES 2695 & 6471 CHASSIS: 0.090" (2.286mm) ALUMINUM ALLOY, WITH CLEAR FINISH