MAP110 BEL | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 6
Technical content
Bel Power Solutions MAP110 Series of power supplies combines low cost and universal input in a board -only power solution to meet commercial and industrial requirements. Full international safety, EMI, and ESD compliance ensure worldwide acceptance. All units bear the CE Mark. Wide dynamic output current and fixed-frequency operation simplifies system level operation. The MAP110 series is configured to an international standard footprint. Input and output connections are made via popular single-row Molex connectors. Single output models feature wide -range output adjustability to meet a wide variety of standard and user -specific output voltage requirements. RoHS Lead-Solder-Exemption Compliant New 5 V Output Models Universal Input 85-264 VAC Industry-Standard Footprint: Input Transient & ESD Compliance to EN61000-4-2/-3/-4 Remote sense and overvoltage protection on single output units and main output of multiple output units Options include Over temperature protection, Power Fail signal, Chassis & Cover Greater than 134,000 hours MTBF
2 MAP110 Series
tech.support@psbel.com MODEL 7 OUTPUT VOLTAGE ADJUSTMENT RANGE CONVECTION COOLED OUTPUT CURRENT FORCED AIR OUTPUT CURRENT 1 LINE REGULATION LOAD REGULATION RIPPLE NOISE 2 INITIAL SETTING ACCURACY MODEL 7 OUTPUT VOLTAGE ADJUSTMENT RANGE CONVECTION COOLED OUTPUT CURRENT 4 FORCED AIR OUTPUT CURRENT 4 LINE REGULATION LOAD REGULATION RIPPLE NOISE2 INITIAL SETTING ACCURACY MAP110-4000G +12V Fixed 5A/9A PK 5A/9A PK 0.2% 1% 1% 11.97V to 12.03V MAP110-4001* MAP110-4002G +12V Fixed 5A/9A PK 5A/9A PK 0.1% 1% 1% 11.97V to 12.03V MAP110-4003* MAP110-4004G MAP110-4010* +12V Fixed 5A/9A PK 5A/9A PK 0.1% 2% 1% 11.97V to 12.03V -12V Fixed 3A/4A PK 3A/4A PK 0.3% 8% 1% -11.5V to -12.5V MAP110-4011G +12V Fixed 5A/9A PK 5A/9A PK 0.1% 1% 1% 11.97V to 12.03V MAP110-4015* +12V Fixed 5A/9A PK 5A/9A PK 0.1% 1% 1% 11.97V to 12.03V
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection BCD.00566_AB MAP110-4200G +12V 11.55V to MAP110-4300* 5,6 +5V Fixed 5A/12A PK 8A/12A PK 0.2% 1% 1% 4.98V to 5.02V MAP110-4305* 5,6 +5V Fixed 5A/12A PK 8A/12A PK 0.2% 1% 1% 4.98V to 5.02V 1 With minimum 200LFM forced-air cooling. 2 Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 3 MAP110-1024 output currents are expressed as 24V/28V operation. 4 Peak loads up to 110 watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 110 watts. 5 Sum of the output currents of V1 + V2 may not exceed 15 A continuous, 22 A peak.
6 Maximum operating ambient temperature of 40°C
7 Non-G models use lead solder exemption and are not recommended for new designs. * O * Obsolete MODEL/OUTPUT OPTION MULTIPLE OUTPUT BOARD ONLY SINGLE OUTPUT BOARD ONLY MULTIPLE OUTPUT ‘C’-COVER SINGLE OUTPUT C’-COVER Convection Continuous / Peak 80W/110W 90W/120W 60W/110W 65W/120W Forced Air 200 LMF 110W 120W 110W 120W PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Input Voltage - AC Continuous input range 85 264 VAC Input Frequency AC input 47 63 Hz Brown Out Protection Lowest AC input voltage when regulation is maintained with full rated loads. 85 VAC Hold-up Time Nominal AC input voltage (110 VAC) 50% load: Full rated load: 20 mS Input Current 85 VAC (110W load) 110VAC (110W load) 3.5
2.8 ARMS
Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Internally limited by thermistor. Vin = 264 VAC (one cycle). 25 °C. 41 APK Operating Frequency Switching frequency of main transformer, (fixed frequency). 20 25 kHz
4 MAP110 Series
tech.support@psbel.com PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Efficiency Full load @ 230 VAC (Varies with distribution of loads among outputs.) 70% typical Minimum Loads Single output models Multiple output models, V1 + V28
1 Amps
Ripple and Noise Full Load, 20 MHz Bandwidth. See Model Selection Chart Output Power Multiple output units with convection cooling. Multiple output units with 200 LFM forced air cooling. 5 80
110 Watts
Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on. 1 % Regulation Varies by output, regulation includes: line changes from 90-132 VAC or 175-264, changes in load starting at 20% load and changing to 100% load. See Model Selection Chart Transient Response Recovery time, to within 1% of initial set point due to a 50-100% load change, 4% max. deviation. (Main output only on multiple output units). 500 µS Turn-on Delay Time required for initial output voltage stabilization. 1 Sec Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. 20 mS 8 Minimum load is required only to meet the regulation limits of V3 and V4. If V3 and V4 are unused, no minimum load is necessary. PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Overvoltage Protection Provided on single output models and the main output of multiple output models. MAP110-1005G MAP110-1012G MAP110-1024G MAP110-4200G MAP110-4300G All other models 6.10 17.3 32.2 13.8 3.7 5.75 7.20 20.2 37.8 16.2 4.35 6.75 V Overload Protection Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. 150 200 % Remote Sense Voltage drop compensated for at the load. 250 mV Input Power Fail Warning Option, TTL compatible logic signal. Time before regulation dropout due to loss of input power at 110 VAC. Active low. 3 5 mS Over temperature Protection Option, system shutdown due to excessive internal temperature. PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Agency Approvals Approved to the latest edition of the following standards; UL/CSA60950-1 2nd, IEC60950-1 2nd and EN60950-1 2nd. Dielectric Withstand Voltage Input to Chassis Input to Output (tested by manufacturer only) 2121
4242 VDC
Electromagnetic Interference, Conducted FCC CFR title 47 Part 15 Sub-Part B - conducted & radiated EN55022 / CISPR 22 conducted EN55022 / CISPR 22 radiated9 B B A Class Input Transient Protection EN61000-4-5 Level 3 2 kV Insulation Resistance Input to output 10 MΩ Leakage Current Per EN60950, 264 VAC 750 μA 9 The following units meet Class B: MAP110-1005, MAP110-4000/4011/4015/4200/4300.
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection BCD.00566_AB PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Altitude Operating Non-operating 10k 50k ASL Ft. Operating Temperature Derate linearly above 50°C by 2.5% per °C to a max. temp. of 70°C At 100% load: At 50% load: Storage Temperature -55 85 °C Temperature Coefficient 0°C to 70°C (after 15 minute warm-up) ±0.03 ±0.05 %/°C Relative Humidity Non-condensing 95 %RH PARAMETER CONDITIONS / DESCRIPTION Weight 0.59 kg (1.3 lbs) Cover Add ‘C’ suffix to model number (Please check with Factory for availability) Power Fail Signal Add ‘P’ suffix to model number. Provides >5 mS typical warning time before main output drops 5%. Warning time increases at reduced load levels. Thermal Shutdown Add ‘T’ suffix to model number. Initiates shut-down in the event of an over temperature condition. Automatic recovery. Please consult factory regarding availability of a specific version.
6 MAP110 Series
Figure 1. Mechanical Drawing equipment used in hazardous environments, or nuclear control systems. date manufactured. Specifications are subject to change without notice.