MAP110 POWER-ONE | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 5
Technical content
Power-One’s MAP110 series of power supplies combines low cost and universal input in a board-only power solution to meet commercial and industrial requirements. Full international safety, EMI, and ESD compliance ensure world-wide acceptance. All units bear the CE Mark. Wide dynamic output current and fixed frequency operation simplifies system level operation. The MAP110 series is configured to an international standard footprint. Input and output connections are made via popular single-row Molex connectors. Single output models feature wide-range output adjustability to meet a wide variety of standard and user specific output voltage requirements.
FEATURES
New 3.3V and 5V Output Models Universal Input 85-264 VAC Industry Standard Footprint: 7.00" x 4.30" x 1.97" (177.8mm x 109.2mm x 50.0mm) Input Transient & ESD Compliance to EN61000-4-2/-3/-4 Greater than 134,000 Hours MTBF Remote Sense and Over-Voltage Protection on Single Output Units and Main Output of Multiple Output Units Options Include Over-Temperature Protection, Power Fail Signal, Chassis & Cover SINGLE OUTPUT MODEL SELECTION CHART MODEL OUTPUT ADJUSTMENT CONVECTION COOLED FORCED AIR LINE LOAD RIPPLE & NOISE INITIAL SETTING VOLTAGE RANGE OUTPUT CURRENT OUTPUT CURRENT REGULATION REGULATION %p-p (NOTE 1) ACCURACY NOTES: 1) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 2) MAP110-1012 output currents are expressed as 12V/15V operation. MAP110-1024 output currents are expressed as 24V/28V operati on. MULTIPLE OUTPUT MODEL SELECTION CHART – 80W CONVECTION COOLED, 110W FORCED AIR COOLED (200 LFM) MODEL OUTPUT ADJUSTMENT CONVECTION COOLED FORCED AIR LINE LOAD RIPPLE & NOISE INITIAL SETTING VOLTAGE RANGE CURRENT (NOTE 1) CURRENT REGULATION REGULATION %p-p (NOTE 2) ACCURACY MAP110-4000 +12V Fixed 5A/9A PK 5A/9A PK 0.2% 1% 1% 11.97V to 12.03V MAP110-4002 +12V Fixed 5A/9A PK 5A/9A PK 0.1% 1% 1% 11.97V to 12.03V Rev. 03/2001
MULTIPLE OUTPUT MODEL SELECTION CHART (CONT.) – 80W CONVECTION COOLED, 110W FORCED AIR COOLED (200 LFM) MODEL OUTPUT ADJUSTMENT CONVECTION COOLED FORCED AIR LINE LOAD RIPPLE & NOISE INITIAL SETTING VOLTAGE RANGE CURRENT (NOTE 1) CURRENT REGULATION REGULATION %p-p (NOTE 2) ACCURACY MAP110-4010 +12V Fixed 5A/9A PK 5A/9A PK 0.1% 2% 1% 11.97V to 12.03V -12V Fixed 3A/4A PK 3A/4A PK 0.3% 8% 1% -11.5V to -12.5V MAP110-4011 +12V Fixed 5A/9A PK 5A/9A PK 0.1% 1% 1% 11.97V to 12.03V MAP110-4015 +12V Fixed 5A/9A PK 5A/9A PK 0.1% 1% 1% 11.97V to 12.03V MAP110-4300 +5V Fixed 5A/12A PK 8A/12A PK 0.2% 1% 1% 4.98V to 5.02V MAP110-4305 +5V Fixed 5A/12A PK 8A/12A PK 0.2% 1% 1% 4.98V to 5.02V NOTES: 1) Peak loads up to 110 Watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 110 Watt s. 2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 3) Sum of the output currents of V1 + V2 may not exceed 15A continuous, 22A peak. New New MAXIMUM OUTPUT RATING: MODEL/OUTPUT MULTIPLE OUTPUT SINGLE OUTPUT MULTIPLE OUTPUT SINGLE OUTPUT MULTIPLE OUTPUT SINGLE OUTPUT OPTION BOARD ONLY BOARD ONLY ‘L’-BRACKET ‘L’-BRACKET ‘C’-COVER C’-COVER CONVECTION CONTINUOUS/PEAK 80W/110W 90W/120W 80W/110W 90W/120W 60W/110W 65W/120W FORCED AIR
200 LFM 110W 120W 110W 120W 110W 120W
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Input Voltage - AC Continuous input range. 85 264 VAC Input Frequency AC input. 47 63 Hz Brown Out Protection Lowest AC input voltage that regulation is maintained with full rated loads. 85 VAC Hold-up Time Nominal AC input voltage (110 VAC) 50% load: 40 mS Full rated load: 20 Input Current 85 VAC (110W load). 3.5 A RMS 110VAC (110W load). 2.8 Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Internally limited by thermistor. Vin = 264 VAC (one cycle). 25°C. 41 A PK Operating Frequency Switching frequency of main transformer, (fixed frequency). 20 25 kHz
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Efficiency Full load, 230 VAC. Varies with distribution of loads among outputs. 65 75 80 % Minimum Loads Single output models. 0 Amps Multiple output models, V1 + V2 (Note 1). 1 Amps Ripple and Noise Full Load, 20 MHz Bandwidth. See Model Selection Chart. Output Power Multiple output units with convection cooling. 5 80 Watts Multiple output units with 200 LFM forced air cooling. 5 110 Watts Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on. 0 V Regulation Varies by output, regulation includes: line changes from 90-132 VAC or 175-264, changes in load starting at 20% load and changing See Model Selection Chart. to 100% load. Transient Response Recovery time, to within 1% of initial set point due to a 50-100% load change, 4% max. deviation. (Main output only on multiple output units). 500 µS Turn-on Delay Time required for initial output voltage stabilization. 1 Sec Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. 20 mS INTERFACE SIGNALS AND INTERNAL PROTECTION PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Overvoltage Protection Provided on single output models and the MAP110-1005 6.10 7.20 main output of multiple output models. MAP110-1012 17.3 20.2 MAP110-1024 32.2 37.8 V MAP110-4200 13.8 16.2 MAP110-4300 3.7 4.35 All other models. 5.75 6.75 Overload Protection Fully protected against output overload and short circuit. 150 200 % Automatic recovery upon removal of overload condition. Remote Sense Voltage drop compensated for at the load. 250 mV Input Power Fail Option, TTL compatible logic signal. Time before regulation dropout due Warning to loss of input power at 110 VAC. Active low. 3 5 mS Overtemperature Protection Option, system shutdown due to excessive internal temperature. SAFETY, REGULATORY, AND EMI SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Agency Approvals UL1950. CSA 22.2 No. 234/950. Approved. EN60950 (TUV). Dielectric Withstand Voltage Input to Output. 2600 VDC Electromagnetic FCC CFR title 47 part 15 sub-part B - conducted & radiated. B Interference, EN55022 / CISPR 22 conducted. B Class Conducted EN55022 / CISPR 22 radiated (Note 2). A Input Transient Protection EN61000-4-5 level 3. 2 kV Insulation Resistance Input to output. 10 M /H9024 Leakage Current Per EN60950, 264 VAC. 750 µA NOTES: 1) Minimum load is required only to meet the regulation limits of V3 and V4. If V3 and V4 are unused, no minimum load is neces sary. 2) The following units meet Class B: MAP110-1005, MAP110-4000/4011/4015/4200/4300. MAP110 SERIES
ENVIRONMENTAL SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Altitude Operating. 10k ASL Ft. Non-operating. 50k ASL Ft. Operating Temperature Derate linearly above 50°C by 2.5% per° C At 100% load: 0 50 °C to a maximum temperature of 70°C. At 50% load: 0 70 °C Storage Temperature -55 85 °C Temperature Coefficient 0°C to 70°C. ±0.03 ±0.05 %/°C Relative Humidity Non-condensing. 95 %RH OPTIONS DESCRIPTION NOTES DIMENSIONS L-Bracket Add ‘L’ suffix to model number. 7.15" x 4.50" x 2.40" (182.0mm x 115.0mm x 61.0mm) (183.0mm x 115.0mm x 61.0mm) Power Fail Add ‘P’ suffix to model number. Provides >5 mS typical warning time before N/A Signal main output drops 5%. Warning time increases at reduced load levels. Thermal Add ‘T’ suffix to model number. Initiates shut-down in the event of an overtemperature N/A Shutdown condition. Automatic recovery. NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Po wer-One, Inc. TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change dependin g on the date manufactured. Specifications are subject to change without notice.
OVERALL WEIGHT: 1.3 LBS (0.59 kg) Contact factory for dimensions for L-bracket and cover.