 Any products mentioned in this catalog are subject to any modification in their appearance and others for improvements withou t prior notification.  The details listed here are not a guarantee of the individual products at the time of ordering. When using the products, you will be asked to check their specifications. Micro Air Pump Motor MAP-AM-265

APPLICATIONS

Blood Pressure monitor for Arm type SPECIFICATIONS Unit : mm DIMENSIONS LABEL 4.1 271.2 6.5 6.5 24.4 2−0.3 + Terminal − TerminalMITSUMI M mark24.6 32.6 30.8 1.7 (67.1) 18.3 0.95 2−2 Items Specifi cations Conditions Rated Voltage 6.0V Voltage Range 5.0~7.0V Pressing Time 11.5sec or less Time to add pressure from 0 to 300mmHg to a tank of 500cc by rated voltage (DC 6V). Current Consumption 430mA or less Maximum current during adding pressure from 0 to 300mmHg to a tank of 500cc by rated voltage(DC 6V). Leakage of Air 3.0mmHg/min or less Decrease of pressure at 30 second after stop pumping to a tank of 500cc up to 40±10mmHg and 300 ± 10mmHg. Maximum Pressure 400mmHg or more Noise 55.0dB or less Noise at 30cm from the pump.