MADCSM0001 MACOM | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 8
Technical content
Features
- Highly Integrated Downconverter
- Operates over 2.8 V to 5 V Supply Voltage
- Dual-Band and Triple-Mode Operation
- High Linearity, IP3 = 10 dBm typical
- Adjustable Gain and IP3
- 4 mm 20-Lead PQFN Plastic Package
Description
M/A-COM’s MADCSM0001 is a downconverter suitable for Dual-Band and Triple-Mode Operation. The MADCSM0001 has a 50-ohm matched input, consumes low DC power and incorporates an on-chip switch that determines CDMA and AMPS mode select. The designer can tailor the linearity and gain performance of the MADCSM0001 according to the system needs. The MADCSM0001 is ideally suited for wireless applications where low noise, low current and high linearity are important features. The MADCSM0001 is fabricated using M/A-COM’s 0.5-micron low noise E/D GaAs MESFET process. The process features full passivation for increased performance and reliability. Ordering Information1 Part Number Package MADCSM0001 Bulk Packaging MADCSM0001TR 1000 piece reel MADCSM0001SMB Sample Board 1. Reference Application Note M513 for reel size information. Pin Configuration Pin No. Function Description
1 CELL MIX Cellular Mixer RF Input/ Mixer IF Output
2 GND DC and RF Ground
3 PCS IFA IN PCS IFA Input
4 GND DC and RF Ground
5 PCS MIX PCS Mixer RF Input/Mixer IF Output
6 PCS LO IN PCS LO Buffer Input (-10 to -5 dBm)
7 GND DC and RF Ground
8 PCS VDD PCS Downconverter Supply Voltage. Must be RF bypassed
9 GND DC and RF Ground
10 CELL LO IN Cellular LO Buffer Input (-10 to -5 dBm)
11 PCS SRC Parallel RC network determines the PCS
IFA Current, Gain and IIP3. 12 PCS IF OUT PCS IF Out. VDD and IF matching required.
13 GND DC and RF Ground
14 CELL IF
Cellular IF Out2. VDD and IF matching required.
15 CELL IF
Cellular IF Out1. VDD and IF matching required.
16 MODE SEL Selects between Cellular IF Out1 and
17 MODE SEL
VDD Mode Select Network Supply Voltage
18 CELL SRC Parallel RC network determines the
Cellular IFA Current, Gain and IIP3.
19 CELL VDD Cellular Downconverter Supply
Voltage. Must be RF bypassed.
20 CELL IFA IN Cellular IFA Input
Absolute Maximum Ratings 2,3 Parameter Absolute Maximum Voltage 6 V Input Power 0 dBm Operating Temperature -30°C to +85°C Storage Temperature -65°C to +150°C 2. Exceeding any one or combination of these limits may cause permanent damage to this device. 3. M/A-COM does not recommend sustained operation near these survivability limits.
Dual-Band/Triple-Mode Downconverter 869 - 893 MHz and 1930 - 1990 MHz MADCSM0001 M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. M/A-COM makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does M/A-COM assume any liability whatsoever arising out of the use or application of any product(s) or information.
- North America Tel: 800.366.2266 / Fax: 978.366.2266 Visit www.macom.com for additional data sheets and product information. Cellular Band - Electrical Specifications: TA = 25°C, Z0 = 50 Ω, VDD = 3.0 V, MODE_SEL = 0 V / 3.0 V RF Frequency = 880 MHz, LO Frequency = 965 MHz, IF Frequency = 85 MHz Parameter Test Conditions Units Min. Typ. Max. LO Power — dBm -10 -8 -5 Conversion Gain LO = -8 dBm dB 5 10 12 Noise Figure LO = -8 dBm dB — 8 — Input IP3 LO = -8 dBm dBm 5 10 — Return Loss RF Port LO Port IF Port dB dB dB Isolation LO to IF RF to IF dB dB Current LO = -8 dBm mA — 10 15 PCS Band - Electrical Specifications: TA = 25°C, Z0 = 50 Ω, VDD = 3.0 V RF Frequency = 1960 MHz, LO Frequency = 1750 MHz, IF Frequency = 210 MHz Parameter Test Conditions Units Min. Typ. Max. LO Power — dBm -10 -8 -5 Conversion Gain LO = -8 dBm dB 9.5 12 14.5 Noise Figure LO = -8 dBm dB — 8 — Input IP3 LO = -8 dBm dBm 4 10 — Return Loss RF Port LO Port IF Port dB Isolation LO to IF RF to IF dB dB Current LO = -8 dBm mA — 13 17 Handling Procedures Please observe the following precautions to avoid damage: Static Sensitivity Gallium Arsenide Integrated Circuits are sensitive to electrostatic discharge (ESD) and can be damaged by static electricity. Proper ESD control techniques should be used when handling these devices.
Dual-Band/Triple-Mode Downconverter 869 - 893 MHz and 1930 - 1990 MHz MADCSM0001 M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. M/A-COM makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does M/A-COM assume any liability whatsoever arising out of the use or application of any product(s) or information.
- North America Tel: 800.366.2266 / Fax: 978.366.2266 Visit www.macom.com for additional data sheets and product information. Recommended PCB Configuration Sample Board Schematic Ref Designation Value Purpose C1 2.7 pF RF Matching C2,C3 1000 pF RF/IF Bypass C4 1 pF RF Matching C5 2 pF RF Matching C6,C7,C8,C12, C14,C15,C16,C17 0.1 µF RF/IF Bypass C9 39 pF IF Matching C10 12 pF IF Matching C11,C13 33 pF IF Matching L1,L11 22 nH RF Matching L2 270 nH IF Matching L3 6.8 nH RF Matching L4 120 nH IF Matching L5,L6 5.1 nH RF/IF Matching L7 15 nH RF Matching L8 33 nH IF Choke L9,L10 150 nH IF Choke R1 56 Ohms PCS Source Bias R2 51 Ohms Cellular Source Bias Case Size 0402 0402 0402 0402 0402 0402 0402 0402 0603 0603 0603 0603 0603 0603 0603 0603 0402 0402 External Circuitry Parts List C1 C2 C5 C6 C10 C11 C12 C14 C13 C15C16C17 L5 L7 L10 L11
Dual-Band/Triple-Mode Downconverter 869 - 893 MHz and 1930 - 1990 MHz MADCSM0001 M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. M/A-COM makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does M/A-COM assume any liability whatsoever arising out of the use or application of any product(s) or information.
- North America Tel: 800.366.2266 / Fax: 978.366.2266 Visit www.macom.com for additional data sheets and product information. Conversion Gain (IF2) Conversion Gain (IF1) Input IP3 (IF1) Input IP3 (IF2) Noise Figure (IF1) Noise Figure (IF2) Typical Performance Curves - Cellular Frequency Band, LO = -8 dBm, VDD= 3.0 V 865 870 875 880 885 890 895 900 +25°C -30°C +85°C Frequency (MHz) 865 870 875 880 885 890 895 900 +25°C -30°C +85°C Frequency (MHz) 865 870 875 880 885 890 895 900 +25°C -30°C +85°C Frequency (MHz) 865 870 875 880 885 890 895 900 +25°C -30°C +85°C Frequency (MHz) 865 870 875 880 885 890 895 900 +25°C -30°C +85°C Frequency (MHz) 865 870 875 880 885 890 895 900 +25°C -30°C +85°C Frequency (MHz)
Dual-Band/Triple-Mode Downconverter 869 - 893 MHz and 1930 - 1990 MHz MADCSM0001 M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. M/A-COM makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does M/A-COM assume any liability whatsoever arising out of the use or application of any product(s) or information.
- North America Tel: 800.366.2266 / Fax: 978.366.2266 Visit www.macom.com for additional data sheets and product information. LO to IF2 Isolation LO to IF1 Isolation RF to IF1 Isolation RF to IF2 Isolation Current (IF1) Current (IF2) Typical Performance Curves - Cellular Frequency Band, LO = -8 dBm, VDD= 3.0 V 865 870 875 880 885 890 895 900 +25°C -30°C +85°C Frequency (MHz) 865 870 875 880 885 890 895 900 +25°C -30°C +85°C Frequency (MHz) 865 870 875 880 885 890 895 900 +25°C -30°C +85°C Frequency (MHz) 865 870 875 880 885 890 895 900 +25°C -30°C +85°C Frequency (MHz) 950 955 960 965 970 975 980 985 +25°C -30°C +85°C Frequency (MHz) 950 955 960 965 970 975 980 985 +25°C -30°C +85°C Frequency (MHz)
Dual-Band/Triple-Mode Downconverter 869 - 893 MHz and 1930 - 1990 MHz MADCSM0001 M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. M/A-COM makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does M/A-COM assume any liability whatsoever arising out of the use or application of any product(s) or information.
- North America Tel: 800.366.2266 / Fax: 978.366.2266 Visit www.macom.com for additional data sheets and product information. RF Port Match LO Port Match IF1 Port Match IF2 Port Match Typical Performance Curves - Cellular Frequency Band, LO = -8 dBm, VDD= 3.0 V -35 -30 -25 -20 -15 -10 929 954 979 1004 +25°C -30°C +85°C Frequency (MHz) -35 -30 -25 -20 -15 -10 844 869 894 919 +25°C -30°C +85°C Frequency (MHz) -35 -30 -25 -20 -15 -10 70 75 80 85 90 95 100 +25°C -30°C +85°C Frequency (MHz) -35 -30 -25 -20 -15 -10 70 75 80 85 90 95 100 +25°C -30°C +85°C Frequency (MHz)
Dual-Band/Triple-Mode Downconverter 869 - 893 MHz and 1930 - 1990 MHz MADCSM0001 M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. M/A-COM makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does M/A-COM assume any liability whatsoever arising out of the use or application of any product(s) or information.
- North America Tel: 800.366.2266 / Fax: 978.366.2266 Visit www.macom.com for additional data sheets and product information. Conversion Gain Input IP3 Typical Performance Curves - PCS Frequency Band, LO = -8 dBm, VDD = 3.0 V LO to IF Isolation Noise Figure RF to IF Isolation Current 1930 1940 1950 1960 1970 1980 1990 +25°C -30°C +85°C Frequency (MHz) 1930 1940 1950 1960 1970 1980 1990 +25°C -30°C +85°C Frequency (MHz) 1930 1940 1950 1960 1970 1980 1990 +25°C -30°C +85°C Frequency (MHz) 1930 1940 1950 1960 1970 1980 1990 +25°C -30°C +85°C Frequency (MHz) 1930 1940 1950 1960 1970 1980 1990 +25°C -30°C +85°C Frequency (MHz) 1720 1730 1740 1750 1760 1770 1780 +25°C -30°C +85°C Frequency (MHz)
Dual-Band/Triple-Mode Downconverter 869 - 893 MHz and 1930 - 1990 MHz MADCSM0001 M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. M/A-COM makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does M/A-COM assume any liability whatsoever arising out of the use or application of any product(s) or information.
- North America Tel: 800.366.2266 / Fax: 978.366.2266 Visit www.macom.com for additional data sheets and product information. LO Port Match RF Port Match Typical Performance Curves - PCS Frequency Band, LO = -8 dBm, VDD = 3.0 V IF Port Match 4 mm 20-Lead PQFN† †Meets JEDEC moisture sensitivity level 1 requirements. -35 -30 -25 -20 -15 -10 1660 1720 1780 1840 +25°C -30°C +85°C Frequency (MHz) -35 -30 -25 -20 -15 -10 1870 1930 1990 2050 +25°C -30°C +85°C Frequency (MHz) -35 -30 -25 -20 -15 -10 180 190 200 210 220 230 240 +25°C -30°C +85°C Frequency (MHz)