M6SXAS MSYSTEM | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

MODEL: M6SXAS M6SXAS SPECIFICATIONS ES-7978 Rev.6 Page 1/4 http://www.m-system.co.jp/ Tension-Clamp Ultra-Slim Signal Conditioners M6S Series DC ALARM (PC programmable) Functions & Features

  • Maintenance-free tension clamp connection
  • 5.9-mm wide ultra-slim design
  • Low profile allows the M6S module mounted in a 120-mm deep panel
  • Provides a relay contact output at preset DC input levels
  • PC programmable
  • High-density mounting
  • Power and status indicator LEDs 5.9 (.23) (3.70) 102 (4.02) mm (inch) MODEL: M6SXAS–[1]–R[2]

ORDERING INFORMATION

  • Code number: M6SXAS-[1]-R[2] Specify a code from below for each [1] and [2]. (e.g. M6SXAS-Z1-R/Q)
  • Input range (e.g. 4 – 20 mA DC)
  • Specify the specification for option code /Q (e.g. /C01/SET) [1] INPUT Current Z1: Range 0 – 50 mA DC (Input resistance 24.9 Ω) Voltage S1: Range -1000 – +1000 mV DC (Input resistance 1 MΩ min.) S2: Range -10 – +10 V DC (Input resistance 1 MΩ min.) (Configurator software is used to change input over the described range of the selected suffix code. For changing between suffix codes, set the Input Range Selector on the side of unit before software adjustment.) OUTPUT Relay; SPDT or transfer contact POWER INPUT DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) [2] OPTIONS blank: none /Q: With options (specify the specification) SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating /C02: Polyurethane coating EX-FACTORY SETTING /SET: Preset according to the Ordering Information Sheet (No. ESU-7828)

RELATED PRODUCTS

  • PC configurator software (model: M6CFG) Downloadable at M-System’s web site. A dedicated cable is required to connect the module to the PC. Please refer to the internet software download site or the users manual for the PC configurator for applicable cable types. GENERAL SPECIFICATIONS Connection Input and output: Tension clamp Power input: Via the Installation Base (model: M6SBS) or Tension clamp Applicable wire size: 0.2 to 2.5 mm2, stripped length 8 mm Housing material: Flame-resistant resin (black) Isolation: Input to output to power Power LED: Green light turns on when the power is supplied. Status indicator LED: Orange LED; Blinking patterns indicate different operating status of the transmitter. Alarm monitor LED: Red LED turns on when the alarm is tripped. Programming: Downloaded from PC Input type and range Input fine adjustments Alarm setpoint (input %) Trip action (High or Low) Relay coil (energized or de-energized) Power ON delay time (0 to 999 sec.) Alarm ON delay time (0 to 999 sec.) Hysteresis (deadband) (input %) Alarm test, and others For detailed information, refer to the users manual for the PC configurator.

MODEL: M6SXAS M6SXAS SPECIFICATIONS ES-7978 Rev.6 Page 2/4 http://www.m-system.co.jp/ Configurator connection: 2.5 dia. miniature jack; RS-232-C level Factory default setting Alarm setpoint: 80 % Trip action: High Relay coil at alarm: Energized Power ON delay time: 5 sec. Alarm ON delay time: 0 sec. Hysteresis (deadband) : 1.0 % INPUT SPECIFICATIONS ■ DC Current: Input resistor incoporated (If not specified, the input range is 4 – 20 mA DC.) Input range: 0 – 50 mA DC Minimum span: 2 mA Offset: Lower range can be any specific value within the input range provided that the minimum span is maintained. ■ DC Voltage

  • Code S1 (narrow spans) Input range: -1000 – +1000 mV DC Minimum span: 100 mV
  • Code S2 (wide spans) Input range: -10 – +10 V DC Minimum span: 1 V Offset: Lower range can be any specific value within the input range provided that the minimum span is maintained. If not specified, the input range is shown below. S1: 0 – 100 mV DC S2: 1 – 5 V DC OUTPUT SPECIFICATIONS ■ Relay Output Relay rating:

250 V AC @2 A (cos ø = 1)

30 V DC @2 A (resistive load)

Maximum switching voltage: 250 V AC or 125 V DC Maximum switching power: 500 VA or 60 W Minimum load: 5 V DC @100 mA Mechanical life: 5 × 106 cycles (rate 180/min.) 0 50 100 Input (%) ▲ Setpoint Output (3–4)ON (3–2)ON

  • Setting Example Hi alarm (coil energized at alarm) or Lo alarm (coil de-energized at alarm) Alarm Trip Operation Terminal No. in parentheses Trip operation in power failure: Terminals 3 – 4 turn ON. INSTALLATION Power consumption: Approx. 0.5 W Operating temperature: -20 to +55°C (-4 to +131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Installation Base (model: M6SBS) or DIN rail Weight: 65 g (2.3 oz) PERFORMANCE in percentage of span Setpoint accuracy (trip point accuracy) : ±0.05 % Setpoint accuracy is inversely proportional to the input span. [Example] Input type 0 – 50 mA, Input range 4 – 20 mA Max. Input Range (50 mA) ÷ Span (16 mA) × 0.05 % = ±0.16 % Temp. coefficient: ±0.01 %/°C (±0.006 %/°F) of max. span Response time: ≤ 0.2 sec. (0 – 100 % at 90 % setpoint) Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (input to output to power to ground) STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 Low Voltage Directive EN 61010-1 Measurement Category II (output) Pollution Degree 2 Input or power to output: Reinforced insulation (300 V) Input to power: Basic insulation (300 V) RoHS Directive EN 50581

MODEL: M6SXAS M6SXAS SPECIFICATIONS ES-7978 Rev.6 Page 3/4 http://www.m-system.co.jp/ EXTERNAL VIEW ■ FRONT VIEW (with the cover open) ■ SIDE VIEW 5 6 7 8 1 2 3 4 vISW1 Input Selector Status Indicator LED Alarm Monitor LED Configurator Jack Power LED The DIP switch setting is required to select input types before setting a precise input range using PC Configurator Software (model: M6CFG). Refer to the instruction manual for detailed procedures. EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch) 94 (3.70) 5.9 (.23) DIN RAIL 35mm wide DIN RAIL HOOK *Use a minus screwdriver: tip width 3.8 mm max., tip thickness 0.5 to 0.6 mm 102 (4.02) [0.5 (.02)]SCREWDRIVER INSERTION ANGLE : approx. 40° WIRE INSERTION ANGLE : approx.35° TEST PROBE max. 2 (.08) dia. SCREWDRIVER INSERTION ANGLE : approx. 35° 5 6 7 8 1 2 3 4

  • When mounting, no extra space is needed between units.

MODEL: M6SXAS M6SXAS SPECIFICATIONS ES-7978 Rev.6 Page 4/4 http://www.m-system.co.jp/ SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM Digital Computation5 POWER Low Drift Amplifier24.9 Ω INPUT SELECTOR ALARM MONITOR LED CONFIGURATOR JACK OUTPUT N.C. N.O. COM INPUT ■ Relay Protection

  • AC Powered • DC Powered Ry CONNECTOR POWER POWER LED STATUS IND. LED Varistor or CR Circuit Diode, Varistor or CR Circuit LOAD Inductive Load (Coil) U LOAD Inductive Load (Coil) Specifications are subject to change without notice.