M50 SENSATA | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 3

Technical content

Features

  • Over 40KW output Capability
  • 8 Different Circuits to Choose from
  • 50 and 100 A outputs
  • UL Recognized E72445 | M50 SERIES POWER MODULES ORDERING OPTIONS Series External Suppressor Circuit Type Load Current AC Line Voltage Free Wheeling Diode M50 50 1 2 F V Required for valid part number For options only and not required for valid part number 1 2 3 4 5 6 7 8 (See schematic diagrams) 1: 120 VAC 2: 240 VAC 3: 280 VAC 4: 380 VAC 5: 480 VAC 50: 50 Amps 100: 100 Amps M50 Blank: Not Included F: Included (Circuits 1 & 2 only) Blank: Not included V: Include (Circuits 1, 2, 3, 4, 6 & 7 only) NOTE: Not all Combinations available Page 1 www.sensata.comCopyright © 2023 Sensata Technologies, Inc.

Tolerances: ±0.02 in / 0.5 mm All dimensions are in: inches [millimeters] 1.880 [47.7] 2.265 [57.5] 1.625 [41.2] .815 [20.7] 0.875 [22.2] 1.750 [44.4] 1.365 [34.6] 1.140 [29.0] 1.055 [26.8] 1.070 [27.2] .475 [12.1] .535 [13.6] MOUNTING HOLE/SLOT 4PLCS. 10-32 SCREW 4 PLCS. MECHANICAL SPECIFICATIONS 4.5 oz (158g) Page 2 Weight (typical) Description Symbol M5050 M50100 Maximum DC Output Current (Tc= 85°C) ID 50 A 100 A Maximum Voltage Drop @ Amps Peak VF 1.35V @ 50A 1.2V @ 100 A -40 - 125°CTJ Repetitive Peak Reverse Voltage (AC Line Nominal) [Vpk] VRRMS ITSM RJC VISOL I² T 2650 0.45°C/W 9350 Operating Junction Temperature Range Maximum I² t for Fusing (t=8.3ms)[A² sec] Maximum Non-Repetitive Surge Current (1/2 Cycle, 60 Hz) [A] Insolation Voltage [Vrms] Maximum Thermal Resistance, Junction to Ceramic Base per Chip [°C/W] 800 1500 2500 0.3°C/W -40 - 125°C 400 (120 VAC) 600 (240 VAC) 800 (280 VAC) 1200 (480 VAC) 1400 (530 VAC) 1600 (600 VAC) ELECTRICAL SPECIFICATIONS CIRCUIT DIAGRAMS AC1 G1 G2 AC AC2 + AC AC1 AC2 AC1 AC2 AC AC1 AC2 AC2 AC1 G1G4 G2G1 AC1 AC2 - + AC1 AC2 G2G1 AC1 AC2 G2G1 AC1 AC2 G2G4 AC1 AC2 AC2AC1 G1G3 AC - + AC1 AC2 AC1 AC2 www.sensata.comCopyright © 2023 Sensata Technologies, Inc.

RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE

  • The product’ s side panels may be hot, allow the product to cool before touching.
  • Follow proper mounting instructions including torque values.
  • Do not allow liquids or foreign objects to enter this product. Failure to follow these instructions can result in serious injury, or equipment damage. HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
  • Disconnect all power before installing or working with this equipment.
  • V erify all connections and replace all covers before turning on power. Failure to follow these instructions will result in death or serious injury. CONTACT USSensata T echnologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’ s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSA T A INTELLECTUAL PROPERTY RIGHT , AND NO LICENSE TO ANY THIRD P ARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT , IS GRANTED HEREIN. SENSA T A DA T A SHEETS ARE PROVIDED “AS IS”. SENSA T A MAKES NO W ARRANTIES OR REPRESENT A TIONS WITH REGARD TO THE DA T A SHEETS OR USE OF THE DA T A SHEETS, EXPRESS, IMPLIED OR ST A TUTORY , INCLUDING ACCURACY OR COMPLETENESS. SENSA T A DISCLAIMS ANY W ARRANTY OF TITLE AND ANY IMPLIED W ARRANTIES OF MERCHANT ABILITY , FITNESS FOR A P ARTICULAR PURPOSE, QUIET ENJOYMENT , QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD P ARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSA T A DA T A SHEETS OR USE THEREOF . All products are sold subject to Sensata’ s terms and conditions of sale supplied at www .sensata.com SENSA T A ASSUMES NO LIABILITY FOR APPLICA TIONS ASSIST ANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THA T IT IS SOLEL Y RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULA TORY AND SAFETY -RELA TED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSA T A COMPONENTS IN ITS APPLICA TIONS, NOTWITHST ANDING ANY APPLICA TIONS-RELA TED INFORMA TION OR SUPPORT THA T MA Y BE PROVIDED BY SENSA T A. Mailing Address: Sensata T echnologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. www.sensata.comCopyright © 2023 Sensata Technologies, Inc. Americas +1 (877) 502 5500 – Option 2 sales.crydom@sensata.com Europe, Middle East & Africa +44 (1202) 416170 ssr-info.eu@sensata.com Asia Pacific sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 Rev. 05/15/2023 ERN 21026 FDE-07-01 Rev.B