SENSOR SOLUTIONS ///M3200 08/2018 Page 1 M3200 Pressure Transducer SPECIFICATIONS  Analog Outputs (V/mA)  14-Bit Digital Output for Pressure and 11-Bit for Temperature  CE Compliance  Weatherproof  0.5% zero offset,1.5 % accuracy (Total error band) The M3200 pressure transducer from the Microfused line of TE is suitable for measurement of liquid or gas pressure, even for difficult media such as contaminated water, steam, and mildly corrosive fluids. The transducer pressure cavity is machined from a solid piece of 17-4PH stainless steel. The standard version includes a 1/4 NPT pipe thread allowing a leak-proof, all metal sealed system. With excellent durability, there are no welds or organics exposed to the pressure media. TE’s proprietary Microfused technology, derived from demanding aerospace applications, employs micromachined silicon piezoresistive strain gages fused with high temperature glass to a stainless-steel diaphragm. This approach achieves media compatibility simply and elegantly while providing an exceptionally stable sensor without the PN junctions of conventional micromachined sensors. This product is geared towards industrial and commercial OEMs for small to high volume applications. Standard configurations are suitable for many applications. Please contact factory for your customization needs.

FEATURES

 One Piece Stainless Steel Construction  Digital Pressure and Temperature Output or Analog mV/Amplified Output  Compact  17-4PH Stainless Steel  Customizable

APPLICATIONS

 Pumps and Compressors  Hydraulic/Pneumatic Systems  Automotive Test Systems  Energy and Water Management  Medical Gas Pressure  Leak Detection  Remote Measuring Systems  General Pressure Measurements

SENSOR SOLUTIONS ///M3200 08/2018 Page 2 STANDARD RANGES Range (psi) Range (bar) Gage/Compound 0 to 100 0 to 007  0 to 250 0 to 017  0 to 500 0 to 035  0 to 01k 0 to 070  0 to 2k5 0 to 170  0 to 05k 0 to 350  0 to 7k5 0 to 500  0 to 10k 0 to 700  PERFORMANCE SPECIFICATIONS (ANALOG) Unless otherwise specified: All parameters measured at 25°C PARAMETERS MIN TYP MAX UNITS NOTES Accuracy (Combined linearity, hysteresis & repeatability) -0.25 0.25 % F.S BFSL Zero offset -0.5 0.5 %F.S. @ 25°C Pressure Cycles 1.0E+6 0~F.S. Cycles Proof Pressure 2X Rated Burst Pressure 5X Rated ≤20kpsi Isolation, Body to Any Lead 50 MΩ @ 250VDC Load Resistance (RL) >100 kΩ Voltage Output Load Resistance <(Supply Voltage-9V)/0.02A Ω Current Output Current Consumption 5 mA Voltage Output Dielectric Strength 2 mA @500 VAC 1 min Long Term Stability (1 year) -0.25 0.25 %Span Compensated Temperature -20 85 °C Operating Temperature -40 125 °C Except Cable 105°C max Storage Temperature -40 125 °C Except Cable 105°C max Weather proof Rating IP67 for cable & M12 type, IP66 for Packard type, IP65 for Form C type Note 1 Rise Time (10% - 90%) <2 ms (mV Output); <3ms (mA Output) Wetted Material 17-4PH Stainless Steel Shock 50g, 11 msec Half Sine Shock per MIL-STD-202G, Method 213B, Condition A Vibration ±20g, MIL-STD-810C, Procedure 514.2-2, Curve L Compliances6 EN 55022 Emissions Class A & B IEC 61000-4-2 Electrostatic discharge immunity (4kv contact / 8kv air discharge) IEC 61000-4-3 Radiated, Radio-Frequency Electromagnetic field immunity (10 V/m; 80M-1GHz; 3 V/m, 1.4 – 2.0GHz; 1 V/m, 2.0 – 2.7GHz) IEC 61000-4-5 Surge (line to line: ±1.0kV/42Ω; Line to case: ±1.0kV/42Ω) IEC 61000-4-6 Immunity to conducted disturbances, induced by radio-frequency fields (150k-80MHz, 3VRMS for current output model, 10VRMS for voltage model)

SENSOR SOLUTIONS ///M3200 08/2018 Page 3 PERFORMANCE SPECIFICATIONS (DIGITAL) Unless otherwise specified: All parameters measured at 25°C & 3.3vDC PARAMETERS MIN TYP MAX UNITS NOTES Output at Zero Pressure 750 1000 1250 Count Output at FS Pressure 14720 15000 15250 Count Current Consumption 3.5 mA Current Consumption (sleep mode) 5 µA Supply Voltage 2.7 5.0 V Proof Pressure 2X Rated Burst Pressure 5X Rated No More than 20kpsi Isolation, Body to Any Lead 50 MΩ @ 250VDC Pressure Cycles 1.00E+6 0~F.S. Cycles Pressure Accuracy (RSS combined Non-Linearity, Hysteresis & Repeatability) -0.25 0.25 %F.S. BFSL @ 25°C Temperature Accuracy -3 3 °C Note 2 Long Term Stability (1 year) -0.25 0.25 %F.S. Compensated Temperature 0 55 °C Compensated Temperature Output 512 1075 Count For reference Operating Temperature -20 +85 °C Storage Temperature -40 +85 °C Response time 3 ms @ 4MHz Non-sleep mode, note 3 Response time 8.4 ms @ 4MHz Sleep mode, note 3 Wetted Material (except elastomer seal) 17-4PH Stainless Steel Shock 50g, 11 msec Half Sine Shock per MIL-STD-202G, Method 213B, Condition A Weather proof Rating3 IP67 Vibration ±20g, MIL-STD-810C, Procedure 514.2-2, Curve L Compliance6 EN 55011 Emissions Class A & B IEC 61000-4-2 Electrostatic Discharge Immunity (4kV contact/8kV air discharge) IEC 61000-4-3 Radiated Radio-Frequency Electromagnetic Field Immunity (1V/m, 80M-1GHz; 3 V/m, 1.4 – 2.0GHz; 1V/m, 2.0-2.7GHz) IEC 61000-4-6 immunity to conducted disturbances, induced by radio-frequency fields (150k-80MHz, 3VRMS) Notes 1. Weather-proof ratings are met when the mating connectors are properly installed and cable termination to dry and clean area. For Cable option, IP67 is guaranteed under room temperature. 2. Reflect pressure port diaphragm temperature over the c ompensated temperature range. 3. Response time is from power on to reading measuremen t data. 4. For all CE compliance test, max allowed output deviation is ±1.5%F.S. 5. All Configurations are built with Voltage Reverse and outp ut Short-Circuit Protections. 6. For communication and interfacing, refer to document ‘Interfacing to MEAS Digital Pressure Modules’ online

SENSOR SOLUTIONS ///M3200 08/2018 Page 4 DIMENSIONS Voltage Output Wiring Connection +Supply -Supply +Output -Output NC. Pins* PREF Vent Packard A A B C - - Hole through Connector Packard B B A C - - Hole through Connector Form C 1 2 3 - 4 Thread through Connector Cable Red Black White Not connected - In Cable M12 1 3 2 4 Hole through Connector Current Output Wiring Connection +Supply -Supply NC. Pins PREF Vent Packard A A B C Hole through connector Packard B B A C Hole through connector Form C 1 2 3, 4 Thread through connector Cable Red Black - In Cable M12 1 3 2,4 Hole through connector Digital Output I2C Wiring Connection +Supply -Supply SCL SDA Cable RED BLACK WHITE GREEN M12 1 3 4 2

SENSOR SOLUTIONS ///M3200 08/2018 Page 5 Notes: *NC. Pins are reserved for factory use only. DO NOT CONNECT. For cable connections, drain wire is internally terminated to pressure port. drain wire is not available for I2C output option * Cable material:4C*22AWG + DRAIN + AL.MYLAR + PVC Jacket Transmitter of gage pressure type requires vent to atmosphere on the pressure reference side.  Accomplished via cable from transmitter or through customer mating connector/cable assembly which has internal vent path (end of cable should be terminated to clean & dry area) Weather-proof Ratings are met when Mating Connectors are installed properly, and cable termination is to dry and clean area. PRESSURE PORTS Code Pressure Port Dim C Recommended Torque [Nm] 4 7/16-20 UNF Male SAE J1926-2 Straight Thread O-Ring BUNA-N 90SH ID8.92xW1.83mm 0.45 [11.43] 18-20 5 1/4-18 NPT 0.65 [16.51] 2-3 TFFT* 6 1/8-27 NPT 0.53 [13.46] 2-3 TFFT* B G1/4 JIS B2351 with NBR O-ring 0.47 [11.94] 30-35 E 1/4-19 BSPT 0.50 [12.70] 2-3 TFFT* P 7/16-20 UNF Female SAE J513 Straight Thread w/ Integral Valve Depressor 0.43 [10.92] 15-16 *Turn From Finger Tight

SENSOR SOLUTIONS ///M3200 08/2018 Page 6 DIGITAL PRESSURE OUTPUT % Output Digital Counts (Decimal) Digital Counts (Hex) 0% 1000 0x3E8 5% 1700 0X6A4 10% 2400 0X960 50% 8000 0X1F40 90% 13600 0X3520 95% 14300 0X37DC 100% 15000 0X3A98

SENSOR SOLUTIONS ///M3200 08/2018 Page 7 DIGITAL TEMPERATURE OUTPUT Output °C Digital Counts (Decimal) Digital counts 0 512 0x200 10 614 0x266 25 767 0x2FF 40 921 0x399 55 1075 0x433

SENSOR SOLUTIONS ///M3200 08/2018 Page 8 OUTPUT (ANALOG) Code Output Supply Ratiometricity Red Black Green White 3 0.5 – 4.5V 5 ± 0.25V Yes +Supply Common Not connected +Output 5 4 – 20mA 9 – 30V No +Supply -Supply Not connected Not connected 6 0 – 5 V 8 – 30V No +Supply -Supply Not connected +Output 7 0 – 10 V 12 – 30 V No +Supply -Supply Not connected +Output 8 1 – 5 V 8 – 30 V No +Supply -Supply Not connected +Output OUTPUT (DIGITAL) Code Output Supply Red Black Green White J I2C 2.7 – 5.0V +Supply -Supply SDA SCL

SENSOR SOLUTIONS ///M3200 08/2018 Page 9

ORDERING INFORMATION

For Analog Output: M32 3 4 – 00000 4 – 250P G Pressure Type G Gage C Compound Output Code Output 3 0.5-4.5V 5 4-20mA 6 0-5V 7 0-10V 8 1~5V Pressure Range psi STD bar STD 100P 007B 250P 017B 500P 035B 01KP 070B 2K5P 170B 05KP 350B 7K5P 500B 10KP 700B Connection

4 Packard A Connector

6 Form C with Mating Connector

9 Packard B Connector

L Cable 0.5m M Cable 1m N Cable 2m P Cable 5m Snubber

0 No snubber

1 With snubber*

4 7/16-20 UNF Male SAE J1926-2 Straight Thread O-ring 90SH ID8.92xW1.83mm 5 1/4-18 NPT 6 1/8-27 NPT B G1/4 JIS B2351 with NBR O-ring E 1/4-19 BSPT P 7/16-20 UNF Female SAE J513 Straight Thread with Integral Valve Depressor Compound pressure range is -14.7 to XXX psiG or -1 to XXX barG. i.e. 200PC: -14.7 to 200psiG, 020BC: -1 to 20 barG *Available for G1/4 port only, more snubber option, please consu lt with factory For Digital Output, see “For Digital Output” Ordering Information All Configurations are built with Voltage Reverse and Output Short-Circ uit Protections. Pressure Ranges between 100-10000psi (7-700bar) are all available. Cha nge Pressure Number Accordingly Click here for Torque Recommendation

SENSOR SOLUTIONS ///M3200 08/2018 Page 10 TE.com/sensorsolutions Measurement Specialties, Inc., a TE Connectivity company. Measurement Specialties, TE Connectivity, TE Connectivity (logo) and EVERY CONNECTION COUNTS are trademarks. All other logos, products and/or company names referred to herein might be trademarks of their respective owners. The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is beli eved to be reliable. However, TE Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity‘s obligati ons shall only be as set forth in TE Connectivity‘s Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application. © 2018 TE Connectivity Ltd. family of companies All Rights Reserved. NORTH AMERICA Measurement Specialties, Inc., a TE Connectivity Company Phone: +1 800-522-6752 Email: customercare.frmt@te.com EUROPE Measurement Specialties (Europe), Ltd., a TE Connectivity Company Phone: +31 73 624 6999 Email: customercare.lcsb@te.com ASIA Measurement Specialties (China), Ltd., a TE Connectivity Company Phone: +86 0400-820-6015 Email: customercare.shzn@te.com For Digital Output: Pressure Type G Gage C Compound Output Code Output J I2C M32 J L – 000 0 0 4 – 250P G Connection L Cable 0.5m M Cable 1m D M12 connector Pressure Range psi STD bar STD 100P 007B 250P 017B 500P 035B 01KP 070B 2K5P 170B 05KP 350B 7K5P 500B 10KP 700B Snubber 4 7/16-20 UNF Male SAE J1926-2 Straight Thread O-ring BUNA-N 90SH ID8.92xW1.83mm 5 1/4-18 NPT 6 1/8-27 NPT B G1/4 JIS B2351 with NBR O-ring E 1/4-19 BSPT P 7/16-20 UNF Female SAE J513 Straight Thread with Integral Valve Depressor Sleep Mode (Digital ONLY)

0 Non-Sleep Mode

1 Sleep Mode

Digital Address (Digital ONLY) 0 0X28H 1 0X36H 2 0X46H 3 0X48H 4 0X51H Compound pressure range is -14.7 to XXX psiG or -1 to XXX barG. Ex. 200PC: -14.7 to 200psiG, 020BC: -1 to 20 barG All Configurations are built with Voltage Reverse and Output Short-Circ uit Protections. *Available for G1/4 port only,More snubber options, please consult wi th factory. Pressure Ranges between 100-10000psi (7-700bar) are all available. Change Pressure Number Accordingly Click here for Torque Recommendation