MODEL: M2BC M2BC SPECIFICATIONS ES-5010 Rev.6 Page 1/8 http://www.m-system.co.jp/ Super-mini Signal Conditioners Mini-M Series COMMUNICATION CONTROLLER (CC-Link) Functions & Features

  • Receiving up to 16 Mini-M modules
  • Enabling interfacing analog I/Os to CC-Link
  • Power supplied through printed wiring on the base SPANSPAN Model SPAN ZERO Model SPAN ZERO Model SPAN ZERO Model SPAN ZERO Model SPAN ZERO Model ZERO Model ZERO Model SPAN ZERO Model SPAN ZERO Model SPAN ZERO Model SPAN ZERO Model SPAN ZERO Model SPAN ZERO Model SPAN ZERO Model SPAN ZERO Model SPAN ZERO MODEL: M2BC–[1][2]-[3]

ORDERING INFORMATION

  • Code number: M2BC-[1][2]-[3] Specify a code from below for [1] through [3]. (e.g. M2BC-161-K) Power input specification for each I/O modules must be the same as that of the base. [1] CAPACITY 04: 4 positions 08: 8 positions 16: 16 positions [2] I/O TYPE 1: Input 2: Output [3] POWER INPUT AC Power K: 85 – 132 V AC (Operational voltage range 85 – 132 V, 47 – 66 Hz) DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) PACKAGE INCLUDES...
  • Terminating resistor (110 Ω, 0.5 W) GENERAL SPECIFICATIONS Capacity: 4, 8 or 16 positions Connection CC-Link: Euro type connector terminal (applicable wire size: 0.2 to 2.5 mm2, stripped length 7 mm) I/O: M3 screw terminals (torque 0.8 N·m) Power input: M3 screw terminals (torque 0.8 N·m) Screw terminal: Nickel-plated steel Isolation: I/O to CC-Link to power to FG1 Power indicator: Green LED turns on with power supplied. CC-Link COMMUNICATION CC-Link: Conforms to Version 1.10 Station type: Remote device station Station No. setting: Rotary switch; 1 – 64 (factory set to:00) Number of occupied stations: M2BC-04: 1 station M2BC-08: 2 stations M2BC-16: 4 stations Remote I/O (RX, RY) is fixed to 32 points. Baud rate setting: Rotary switch (156kbps(factory setting), 625kbps, 2.5Mbps, 5Mbps, 10Mbps) Transmission cable: Approved for CC-Link L RUN indicator: Red LED turns on in an normal condition. L ERR. indicator: Red LED turns on or flashes in an abnormality; off with wire breakdown. SD indicator: Red LED turns on when transmitting. RD indicator: Red LED turns on when receiving. INPUT SPECIFICATIONS Input modules: Mini-M series; output 1 – 5 V DC; (Each input must be isolated by signal conditioners. Non- isolated modules such as M2BW is not usable.) ■ Analog Input Input range: See each I/O module spec. Isolation: Transformer (by Mini-M module) A/D conversion output: Signed binary Signal range 0 – 100 % is converted into hexadecimal 0000 – 2710 (0 – 10000). -15 to 0 % is a negative range represented by 2's complements. Overall range is represented by hexadecimal FA24 – 2CEC

MODEL: M2BC M2BC SPECIFICATIONS ES-5010 Rev.6 Page 2/8 http://www.m-system.co.jp/ 0 1 2 3 4 5 6 7 8 9101112131415 RWr n+0 SIGN BIT INPUT 1 A/D CONVERSION DATA RWr n+1 SIGN BIT INPUT 2 A/D CONVERSION DATA RWr n+2 SIGN BIT INPUT 3 A/D CONVERSION DATA RWr n+3 SIGN BIT INPUT 4 A/D CONVERSION DATA RWr n+7 SIGN BIT INPUT 8 A/D CONVERSION DATA RWr n+11 SIGN BIT INPUT 12 A/D CONVERSION DATA RWr n+15 SIGN BIT INPUT 16 A/D CONVERSION DATA RWr n+0 through RWr n+3 for 4 inputs. RWr n+0 through RWr n+7 for 8 inputs. RWr n+0 through RWr n+15 for 16 inputs. ■ A/D CONVERSION DATA OUTPUT SPECIFICATIONS Output modules: Model M2VS; input 1 – 5 V DC ■ Analog Output Output range: See model M2VS spec. Isolation: Transformer D/A conversion output: Signed binary Signal range 0 – 100 % is converted into hexadecimal 0000 – 2710 (0 – 10000). -15 to 0 % is a negative range represented by 2's complements. Overall range is represented by hexadecimal FA24 – 2CEC 0 1 2 3 4 5 6 7 8 9101112131415 RWw n+0 SIGN BIT OUTPUT 1 D/A CONVERSION DATA RWw n+1 SIGN BIT OUTPUT 2 D/A CONVERSION DATA RWw n+2 SIGN BIT OUTPUT 3 D/A CONVERSION DATA RWw n+3 SIGN BIT OUTPUT 4 D/A CONVERSION DATA RWw n+7 SIGN BIT OUTPUT 8 D/A CONVERSION DATA RWw n+11 SIGN BIT OUTPUT 12 D/A CONVERSION DATA RWw n+15 SIGN BIT OUTPUT 16 D/A CONVERSION DATA RWw n+0 through RWw n+3 for 4 outputs. RWw n+0 through RWw n+7 for 8 outputs. RWw n+0 through RWw n+15 for 16 outputs. ■ D/A CONVERSION DATA INSTALLATION Power Consumption:

  • AC: approx. 6 VA without I/O module approx. 30 VA with 4 modules (M2DY) approx. 50 VA with 8 modules (M2DY) approx. 90 VA with 16 modules (M2DY) Current consumption:
  • DC approx. 0.25 A without I/O module approx. 1 A with 4 modules (M2DY) approx. 1.5 A with 8 modules (M2DY) approx. 2.5 A with 16 modules (M2DY) Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Atmosphere: No corrosive gas or heavy dust Mounting: Surface Weight: Without I/O module M2BC-04 1.2 kg (2.6 lb) M2BC-08 1.5 kg (3.3 lb) M2BC-16 2 kg (4.4 lb)

MODEL: M2BC M2BC SPECIFICATIONS ES-5010 Rev.6 Page 3/8 http://www.m-system.co.jp/ PERFORMANCE in percentage of span A/D conversion: Accuracy of input module ±0.1% D/A conversion: Accuracy of M2VS ±0.1 % Permissible power failure duration: ≤ 10 msec. Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 1000 V AC @1 minute (power to I/O module to CC-Link module to FG1) COMM. MODULE FRONT PANEL L RUN PU-2 B RATE STATION NO. L ERR. SD RD PWR 4321 9 8 76 5 4321 9 8 76 5 4321 9 8 76 X10 E F D C B A A: Modular jack for factory calibration B: Power LED C: Station No. Setting D: Baud rate Setting E: Status indicator LED F: Euro type connector terminal for CC-Link COMMUNICATION CABLE CONNECTIONS DA DB DG SLD FG MASTER UNIT DA DB DG SLD FG M2BC DA DB DG SLD FG I/O UNIT TERMINATOR blue white yellow

MODEL: M2BC M2BC SPECIFICATIONS ES-5010 Rev.6 Page 4/8 http://www.m-system.co.jp/ EXTERNAL DIMENSIONS unit: mm (inch) ■ M2BC-041 (INPUT BASE) 1 2 3 4 5 8 1 4 5 8 1 4 5 8 1 4 5 8 1 4 FG1 13 14 CH4CH1 130 (5.12) 100 (3.94) 6 (.24) 170 (6.69) 190 (7.48) 210 (8.27) 27 (1.06) 2–M3 POWER TERMINALS CT PROTECTOR (CTM2) 16–M3 INPUT TERMINALS 125 (4.92) * 130 (5.12) * 165 (6.50) required for pneumatic tubing for M2PV. ** Attached to M2CA and M2CE. ■ M2BC-042 (OUTPUT BASE) FG1 13 14 1 2 3 4 CH1 CH2 CH3 CH4 9 12 9 12 9 12 9 12 6 (.24) 8–M3 OUTPUT TERMINALS 2–M3 POWER TERMINALS 125 (4.92) 100 (3.94) 170 (6.69) 190 (7.48) 210 (8.27)

MODEL: M2BC M2BC SPECIFICATIONS ES-5010 Rev.6 Page 5/8 http://www.m-system.co.jp/ ■ M2BC-081 (INPUT BASE) 1 2 3 4 5 6 7 8 5 8 1 4 5 8 1 4 5 8 1 4 5 8 1 4 5 8 1 4 5 5 8 8 1 4 1 4 CH7CH1 5 8 1 4 FG1 13 14 CH8 130 (5.12) 100 (3.94) 6 (.24) 260 (10.24) 280 (11.02) 300 (11.81) 27 (1.06) 2–M3 POWER TERMINALS 32–M3 INPUT TERMINALS 125 (4.92) * 130 (5.12) CT PROTECTOR (CTM2)** * 165 (6.50) required for pneumatic tubing for M2PV. ** Attached to M2CA and M2CE. ■ M2BC-082 (OUTPUT BASE) FG1 13 14 1 2 3 4 5 6 7 8 9 12 CH3 CH4 CH5 CH6 CH7 CH8 9 12 9 12 CH1 CH2 9 12 9 12 9 12 9 12 9 12 6 (.24) 16–M3 OUTPUT TERMINALS 130 (5.12) 100 (3.94) 260 (10.24) 280 (11.02) 300 (11.81) 125 (4.92) 130 (5.12) 2–M3 POWER TERMINALS

MODEL: M2BC M2BC SPECIFICATIONS ES-5010 Rev.6 Page 6/8 http://www.m-system.co.jp/ ■ M2BC-161 (INPUT BASE) 5 8 1 4 5 8 1 4 5 8 1 4 5 8 1 4 5 8 1 4 5 8 CH5CH1 5 8 1 4 5 8 1 4 5 8 1 4 5 8 1 4 5 8 FG1 1 4 13 14 1 2 3 4 5 5 85 85 85 85 8 6 7 8 9 10 1 41 41 41 41 4 11 12 13 14 15 16 CH10CH6 CH16CH11 130 (5.12) 100 (3.94) 6 (.24) 440 (17.32) 460 (18.11) 480 (18.90) 27 (1.06) 2–M3 POWER TERMINALS 64–M3 INPUT TERMINALS 125 (4.92) * 130 (5.12) CT PROTECTOR (CTM2)** * 165 (6.50) required for pneumatic tubing for M2PV. ** Attached to M2CA and M2CE. ■ M2BC-162 (OUTPUT BASE) FG1 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 9 12 CH11 CH12 CH13 CH14 CH15 CH16 9 12 9 12 9 12 9 12 9 12 9 12 CH6 CH7 CH8 CH9 CH10 9 12 9 12 9 12 9 12 9 12 CH1 CH2 CH3 CH4 CH5 9 12 9 12 9 12 9 12 6 (.24) 32–M3 OUTPUT TERMINALS 130 (5.12) 100 (3.94) 440 (17.32) 460 (18.11) 480 (18.90) 2–M3 POWER TERMINALS 125 (4.92) 130 (5.12)

MODEL: M2BC M2BC SPECIFICATIONS ES-5010 Rev.6 Page 7/8 http://www.m-system.co.jp/ MOUNTING REQUIREMENTS unit: mm (inch) ■ M2BC-04 100 (3.94) 190 (7.48) 4–M5 SCREW ■ M2BC-08 100 (3.94) 280 (11.02) 4–M5 SCREW ■ M2BC-16 100 (3.94) 460 (18.11) 4–M5 SCREW SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM Ch.1 INPUT Ch.16* INPUT ISOLATION Ch.2 INPUT ISOLATION ISOLATION A / D or D / A Conv. I / O CPU Communication CPU SERIAL TRANSMISSION LINE MODULAR JACK ROTARY SW INDICATOR LED DA DB DG SLD FG U(+) V(–) POWER To Other CC-Link Devices Ch.1 OUTPUT Ch.16* OUTPUT Ch.2 OUTPUT I/O MODULESCOMMUNICATION MODULE ■ INPUT BASE ■ OUTPUT BASE * Up to Ch.4 for M2BC-04, Ch.8 for M2BC-08. FG1 Modular Jack for Factory Calibration

MODEL: M2BC M2BC SPECIFICATIONS ES-5010 Rev.6 Page 8/8 http://www.m-system.co.jp/ Specifications are subject to change without notice.