M12CM OMEGA | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 5
Technical content
C M12CM-EXTT-K-SF-SMPWM-3 M12 Cables with Compensated Connectors for Thermocouples U Straight and Right Angled M12 Field Mountable Connector Sensor End U Compensated Thermocouple Cable, Sockets and Pins U Two Cable Insulation Options Available in IEC and ANSI Color Codes U Variety of Connection Methods to Work with Your Instrumentation U Vibration Tested to MIL-STD-202G, Method 204D, Test Condition A (10g’s from 10 to 500 Hz) When Installed on an M12 Probe Model Number Options KeyTypical M12CM Cable Configuration M12CM Series M12CM-EXTP-K-SM-1.5 straight connector shown smaller than actual size. Right angle available. M12KIN-1/8-U-6-A thermocouple sensor. M12CM-EXTP-K-RF-1.5 cable. Back End Connector Options (Instrument Attachment) M12CM 25 mm (1") stripped leads (standard) OSTWF OSTW female connector OSTWM OSTW male connector SMPWF SMPW-CC connector (female) SMPWM SMPW-CC connector (male) SF M12 straight socket connector (female) SM M12 straight pin connector (male) RF M12 right angled socket connector (female) RM M12 right angled male connector (male) Cable Length (m) 1.5, 3, 5, 10, or 20 Front End Connector Options (Sensor Attachment) SF M12 straight socket connector (female) SM M12 straight plug connector (male) RF M12 right angled socket connector (female) RM M12 right angled plug connector (male) Cable Options EXTP Extension grade 24 AWG stranded, PFA insulated on conductors, PVC jacketed and polyurethane overmold EXTT Extension grade 24 AWG stranded, PFA insulated on conductors and the jacket, and an LCP overmold Thermocouple Type Length in Meters Note: A female connector is needed at one end for attaching the cable to any of our M12 thermocouple probes.
M12 Thermocouple Cables (Cable Termination Options with Compensated Connectors) SMPW OSTW (1.26) Typ ø13 (0.53) Typ As specified in meters (1.00) Typ 31 (1.23) M12X1 Thread (1.07) Female extension cable Male extension cable 1 2 M12 Connector (Sensor End) M12CM-EXTP-K-RF-1.5 cable assembly with stripped leads shown smaller than actual size. Right Dimensions: mm (inch) ø = diameter Cable Wiring M12 Connector Type J Type K Type T Type E OSTW SMPWPin Number ANSI IEC ANSI IEC ANSI IEC ANSI IEC
1 N/C N/C N/C N/C N/C N/C N/C N/C N/C N/C
2 White Black Y ellow Green Blue Brown Purple Violet + +
3 Red White Red White Red White Red White – –
4 N/C N/C N/C N/C N/C N/C N/C N/C N/C N/C
Connector Color Black Black Y ellow Green Blue Blue Purple Violet N/C N/C
Right angle connector cable ø13 (0.53) Typ As specified in meters (1.26) M12X1 Thread (1.78) (1.23) (2.00) ø13 (0.53) Typ As specified in meters Male connector end Female connector end M12X1 Thread (1.07) Female extension cable Male extension cable ø13 (0.53) Typ As specified in meters (1.00) Typ M12X1 Thread (1.78) ø14 (0.57) Typ (2.00) M12CM-EXTP-J-RF-RM-1.5 cable assembly shown smaller than actual size.M12CM-EXTT-K-SF-1.5 cable assembly shown smaller than actual size. C Dimensions: mm (inch) ø = diameter
Model No. Cable Sensor Connector* Length meters (feet) M12CM-EXTT-K-SF-1.5 PFA insulated, 24 AWG stranded, PVC jacket and polyurethane overmold, LCP overmold, maximum temperature 250°C (482°F) Note: A female connector is needed at one end for attaching the cable to any of our M12 thermocouple probes. Type K M12 straight socket with stripped leads on other end (another connector can be added) 1.5 (4.9) M12CM-EXTT-K-SF-3 3 (9.8) M12CM-EXTT-K-SF-5 5 (16.4) M12CM-EXTT-K-SF-10 10 (32.8) M12CM-EXTT-K-SF-20 20 (65.6) M12CM-EXTT-K-RF-1.5 Type K M12 right angled socket with stripped leads on other end (another connector can be added) 1.5 (4.9) M12CM-EXTT-K-RF-3 3 (9.8) M12CM-EXTT-K-RF-5 5 (16.4) M12CM-EXTT-K-RF-10 10 (32.8) M12CM-EXTT-K-RF-20 20 (65.6) M12CM-EXTT-J-SF-1.5 Type J M12 straight socket with stripped leads on other end (another connector can be added) 1.5 (4.9) M12CM-EXTT-J-SF-3 3 (9.8) M12CM-EXTT-J-SF-5 5 (16.4) M12CM-EXTT-J-SF-10 10 (32.8) M12CM-EXTT-J-SF-20 20 (65.6) M12CM-EXTT-J-RF-1.5 Type J M12 right angled socket with stripped leads on other end (another connector can be added) 1.5 (4.9) M12CM-EXTT-J-RF-3 3 (9.8) M12CM-EXTT-J-RF-5 5 (16.4) M12CM-EXTT-J-RF-10 10 (32.8) M12CM-EXTT-J-RF-20 20 (65.6) M12CM-EXTT-T-SF-1.5 Type T M12 straight socket with stripped leads on other end (another connector can be added) 1.5 (4.9) M12CM-EXTT-T-SF-3 3 (9.8) M12CM-EXTT-T-SF-5 5 (16.4) M12CM-EXTT-T-SF-10 10 (32.8) M12CM-EXTT-T-SF-20 20 (65.6) M12CM-EXTT-T-RF-1.5 Type T M12 right angled socket with stripped leads on other end (another connector can be added) 1.5 (4.9) M12CM-EXTT-T-RF-3 3 (9.8) M12CM-EXTT-T-RF-5 5 (16.4) M12CM-EXTT-T-RF-10 10 (32.8) M12CM-EXTT-T-RF-20 20 (65.6) M12CM-EXTT-E-SF-1.5 Type E M12 straight socket with stripped leads on other end (another connector can be added) 1.5 (4.9) M12CM-EXTT-E-SF-3 3 (9.8) M12CM-EXTT-E-SF-5 5 (16.4) M12CM-EXTT-E-SF-10 10 (32.8) M12CM-EXTT-E-SF-20 20 (65.6) M12CM-EXTT-E-RF-1.5 Type E M12 right angled socket with stripped leads on other end (another connector can be added) 1.5 (4.9) M12CM-EXTT-E-RF-3 3 (9.8) M12CM-EXTT-E-RF-5 5 (16.4) M12CM-EXTT-E-RF-10 10 (32.8) M12CM-EXTT-E-RF-20 20 (65.6)
C Model No. Cable Sensor Connector* Length Meters (Feet) M12CM-EXTP-K-SF-1.5 PFA insulated, 24 AWG stranded, PVC jacket and polyurethane overmold, maximum temperature 105°C (221°F) Note: A female connector is needed at one end for attaching the cable to any of our M12 thermocouple probes. Type K M12 straight socket with stripped leads on other end (another connector can be added) 1.5 (4.9) M12CM-EXTP-K-SF-3 3 (9.8) M12CM-EXTP-K-SF-5 5 (16.4) M12CM-EXTP-K-SF-10 10 (32.8) M12CM-EXTP-K-SF-20 20 (65.6) M12CM-EXTP-K-RF-1.5 Type K M12 right angled socket with stripped leads on other end (another connector can be added) 1.5 (4.9) M12CM-EXTP-K-RF-3 3 (9.8) M12CM-EXTP-K-RF-5 5 (16.4) M12CM-EXTP-K-RF-10 10 (32.8) M12CM-EXTP-K-RF-20 20 (65.6) M12CM-EXTP-J-SF-1.5 Type J M12 straight socket with stripped leads on other end (another connector can be added) 1.5 (4.9) M12CM-EXTP-J-SF-3 3 (9.8) M12CM-EXTP-J-SF-5 5 (16.4) M12CM-EXTP-J-SF-10 10 (32.8) M12CM-EXTP-J-SF-20 20 (65.6) M12CM-EXTP-J-RF-1.5 Type J M12 right angled socket with stripped leads on other end (another connector can be added) 1.5 (4.9) M12CM-EXTP-J-RF-3 3 (9.8) M12CM-EXTP-J-RF-5 5 (16.4) M12CM-EXTP-J-RF-10 10 (32.8) M12CM-EXTP-J-RF-20 20 (65.6) M12CM-EXTP-T-SF-1.5 Type T M12 straight socket with stripped leads on other end (another connector can be added) 1.5 (4.9) M12CM-EXTP-T-SF-3 3 (9.8) M12CM-EXTP-T-SF-5 5 (16.4) M12CM-EXTP-T-SF-10 10 (32.8) M12CM-EXTP-T-SF-20 20 (65.6) M12CM-EXTP-T-RF-1.5 Type T M12 right angled socket with stripped leads on other end (another connector can be added) 1.5 (4.9) M12CM-EXTP-T-RF-3 3 (9.8) M12CM-EXTP-T-RF-5 5 (16.4) M12CM-EXTP-T-RF-10 10 (32.8) M12CM-EXTP-T-RF-20 20 (65.6) M12CM-EXTP-E-SF-1.5 Type E M12 straight socket with stripped leads on other end (another connector can be added) 1.5 (4.9) M12CM-EXTP-E-SF-3 3 (9.8) M12CM-EXTP-E-SF-5 5 (16.4) M12CM-EXTP-E-SF-10 10 (32.8) M12CM-EXTP-E-SF-20 20 (65.6) M12CM-EXTP-E-RF-1.5 Type E M12 right angled socket with stripped leads on other end (another connector can be added) 1.5 (4.9) M12CM-EXTP-E-RF-3 3 (9.8) M12CM-EXTP-E-RF-5 5 (16.4) M12CM-EXTP-E-RF-10 10 (32.8) M12CM-EXTP-E-RF-20 20 (65.6) * All models have stripped leads termination, connector can be added. For longer cables, change last number in model number to the desired length in meters, for an additional cost per meter. For IEC colors add “I” after the thermocouple type, ie “KI”, no additional cost. To add a connector add “-SMPWF” or “-SMPWM”, “-OSTWF” or “-OSTWM”, “-SF”, “-SM”, “-RF” or “-RM” for an additional cost. Ordering Examples: M12CM-EXTT-K-SF-3, Type K thermocouple, 3 m (9.8') cable with PFA insulated and jacketed and female M12 connector. M12CM-EXTT-K-SF-SMPWM, Type K thermocouple, 5 m (16.4') cable with PFA insulated and jacketed and female M12 connector and flat pin male connector.