FEATURES:(1)10.4 ” VGA color display with High Luminance (400cd/m 2 ) (2)Wide Viewing Angle (Vertical: 1 2 0 , Horizontal: 1 4 0 ) (3)Built in Long Life Lamps (50,000 h) MECHANICAL SPECIFICATIONS Item Specifications Dimensional Outline (typ.) 238.5( W) x 177.5( H) x 12max( D) mm Number of Pixels 640( W) x 480( H) pixels Active Area 211.2( W) x 158.4( H) mm Pixel Pitch 0.33( W) x 0.33( H) Weight (approximately) 500g Backlight Twin CCFLs, Sidelight type ABSOLUTE MAXIMUM RATINGS Item Min. Max. Unit ( VDD ) - 0.3 6.5 V Supply Voltage ( VFL ) 0 2.0 kV(rms) FL Driving Frequency ( fFL ) --- 100 kHz Input Signal Voltage ( VIN ) - 0.3 VDD +0.3 V Operating Temperature (Note - 10 65 °C Storage Temperature - 20 80 °C Storage Humidity (Max. wet bulb temperature = 39 °C) 10 90 %(RH) Note) Only operation is guarantied at Operating Temperature. Display quality is evaluated at +25 °C. ELECTRICAL SPECIFICATION ( Ta=25 °C) ( RECOMMENDED OPERATION CONDITION ) Item Min. Typ. Max. Unit Remarks 4.75 5.0 5.25 V VDD :5V ( VDD ) 3.0 3.3 3.6 V VDD :3.3V Supply Voltage ( VFL ) --- 460 --- V(rms) FL Start Voltage 1200 --- 1900 V(rms) Ta= - 10 °C High Level Input Voltage ( VIH ) 0.7 V DD --- V DD Low Level Input Voltage ( VIL ) 0 --- 0.3 V DD V * 1 ( IDD ) --- 225 --- mA Current Consumption * 2 ( IFL ) 3.0 6.0 6.5 mA(rms) *1 *2 Power Consumption --- 6.3 --- W IFL =6.0mA(rms) VDD :3.3V *1 : 8 color bars pattern *2 : Except the efficiency of FL inverter OPTICAL SPECIFICATION ( Ta=25 °C) Item Min. Typ. Max. Unit Remarks Contrast Ratio ( CR) 25 0 50 0 --- --- (Upper+Lower) --- 120 --- ° Viewing Angle ( CR ≥ 10) (Left+Right) --- 140 --- ° ( τr ) --- --- 50 ms Response Time ( τf) --- --- 50 ms Luminance --- 400 --- cd/m 2 IFL =6.0mA(rms) Lamp Life Time (MTBF)* 3 * 4 50,000 h *3 : Conditions ; Ta=2 5 °C, IFL =6.0mA(rms), continuous lighting *4 : Definitions of failure ; 1) Lcd luminance becomes half of the minimum value. 2) Lamp doesn ’t light normally. *The information contained herein is presented only as a guide for the applicati ons of our products. No responsibility is assumed by Toshiba Matsushita Display Technology or other rights of the third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Toshiba Ma tsushita Display Technology or others. *The information contained herein may be changed without prior notice. It is therefore advisable to contact Toshiba Matsushita Display Technology before proceeding with the design of equipment incorporating this prod uct. 26cm COLOUR TFT - LCD MODULE (10.4 TYPE) LTD104C11S (a-Si TFT) TENTATIVE Toshiba Matsushita Display Technology Co., Ltd All information is subject to change without notice. Please read bottom notes.
Unit : mm Standard tolerance : ± 0.5 (66.3) ( D F 1 4 H - 2 P - 1 . 2 5 H , D F 1 4 H - 3 0 P - 1 . 2 5 H ) 2 1 3 . 2 ( V i e w i n g A r e a ) 9.5 9.5 3 . 8 8 . 7 7 9 4 7 14.6132.6 161.8(BezelOpening) 177.5 (157.1) 20.4 158.4(ActiveArea) 2 3 8 . 5 ( 2 3 4 . 7 ) 2 3 0 . 9 2 1 4 . 6 ( B e z e l O p e n i n g ) ( 1 1 6 ) 37.5 1 1 . 5 2 . 5 2 . 5 1 0 0 160.4(ViewingArea) T E N T A T I V E 3 . 5 3 . 5 3 . 5 3 . 5 + 1 0 + 1 + 1 +1 I / F C o n n e c t o r ( R e a r S i d e ) 2 1 1 . 2 ( A c t i v e A r e a )
SEQUENCE OF POWER SUPPLIES AND SIGNALS
tv‚†p tvds tvde tvblnk DE 479 480 1 2 th thw HSYNC thfp thds thde DE 640 RGB data NCLK 1 2 3 4 5
TIMING SPECIFICATION 1) 2) 3) 4) 5) 6) Item Symbol min. typ. Max. unit Frame Period tv 500 525 550 th Vertical blanking Term tvblnk 20 45 70 th V - sync Pulse Width tvw 2 - - th Vertical Front Porch tvfp 2 - - th Vertical Data Sync P eriod tvds 6 - - th Vertical Display Term tvde 480 480 480 th Horizontal Period th 740 800 860 tc H - sync Pulse Width thw 8 160 - tc Horizontal Front Porch thfp 8 - - tc Horizontal Data Sync Period thds 8 - - tc Horizontal Display Term thde 640 640 640 tc Clock Period tc 35.0 39.7 - n s Clock “ H ” Time tch 10.0 - - ns Clock “ L ” Time tcl 10.0 - - ns Data Setup Time tds 5.0 - - ns Data Hold Time tdh 10.0 - - ns Note 1) If NCLK is fixed to "H" or "L" level for certain period while DE is supplied, the panel may be damaged. Note 2) Please adjust LCD operating signal timing and FL driving frequency, to optimize the display quality. There is a possibility that flicker is observed by the interference of LCD operating signal timing and FL driving condition (especially driving frequency), even if the condition satisfies above timing specifications and recommended operating conditions shown in 3. Note3 ) Do not make tv, th and tvds fluctuate. Note4) In case of using the long frame period, the deterioration of display quality, noise etc. may be occurred. Note5) NCLK count of each Horizontal Scanning Time should be always the same. V - Blanking period should be “ n” X “ Horizontal S canning Time ” . ( n: integer) Frame period should be always the same.
CONNECTOR PIN ASSIGNMENT FOR INTERFACE CN1 INPUT SIGNAL Connector : DF14H - 30P - 1.25H / HIROSE ELECTRIC CO., LTD. Mating Connector : DF14 - 30S - 1.25C, Contact Pin : DF14 - 2628SCF Terminal No. Symbol Function
1 GND
2 NCLK SAMPLI NG CLOCK
3 H - Sync HORIZONTAL SYNC. 4 V - Sync VERTICAL SYNC.
5 GND
6 R0 2) RED DISPLAY DATA (LSB)
7 R1 2) RED DISPLAY DATA
8 R2 2) RED DISPLAY DATA
9 R3 2) RED DISPLAY DATA
10 R4 2) RED DISPLAY DATA
11 R5 2) RED DISPLAY DATA (MSB)
12 GND
13 G0 2) GR EEN DISPLAY DATA (LSB)
14 G1 2) GREEN DISPLAY DATA
15 G2 2) GREEN DISPLAY DATA
16 G3 2) GREEN DISPLAY DATA
17 G4 2) GREEN DISPLAY DATA
18 G5 2) GREEN DISPLAY DATA (MSB)
19 GND
20 B0 2) BLUE DISPLAY DATA (LSB)
21 B1 2) BLUE DISPLAY DATA
22 B2 2) BLUE DISP LAY DATA
23 B3 2) BLUE DISPLAY DATA
24 B4 2) BLUE DISPLAY DATA
25 B5 2) BLUE DISPLAY DATA (MSB)
26 DE DATA ENABLE
27 GND
28 VDD +3.3V (+5.0V)POWER SUPPLY 29 VDD +3.3V (+5.0V)POWER SUPPLY
30 GND
Connector : DF14H - 2P - 1.25H / HI ROSE ELECTRIC CO., LTD. Mating Connector : DF14 - 2S - 1.25C, Contact Pin : DF14 - 2628SCF Terminal No. Symbol Function
1 U D VERTICAL REVERSE( “ L ” level or Open ; normal, ” H ” level ; reverse)
2 R L HORIZONTAL REVERSE ( “ L ” level or Open ; normal , ” H ” level ; reverse)
Connector : BHR - 04VS - 1 / JAPAN SOLDERLESS TERMINAL MFG CO., LTD. Mating Connector 3) : SM04(4.0)B - BHS - 1 / JAPAN SOLDERLESS TERMINAL MFG CO., LTD. Terminal No. Symbol Function
1 V FLH1 CCFL P ower Supply ( high voltage)
2 V FLH2 CCFL Power Supply ( high voltage)
3 NC 1) Non Connection (open)
4 V FLL CCFL Power Supply (low voltage)
Note 1) NC terminal should be open. Note 2) See next page. Note 3) Take away terminal No.3 of the mating connecto r. If does not take away, it may cause smoke burn of electrical parts by high voltage.
256k (k=1024) COLORS COMBINATION TABLE Display R5 R4 R3 R2 R1 R0 G5 G4 G3 G2 G1 G0 B5 B4 B3 B2 B1 B0 Gray Scale Level Black L L L L L L L L L L L L L L L L L L - Blue L L L L L L L L L L L L H H H H H H - Green L L L L L L H H H H H H L L L L L L - Light Blue L L L L L L H H H H H H H H H H H H - Red H H H H H H L L L L L L L L L L L L - Purple H H H H H H L L L L L L H H H H H H - Yellow H H H H H H H H H H H H L L L L L L - Basic Color White H H H H H H H H H H H H H H H H H H - Black L L L L L L L L L L L L L L L L L L L 0 L L L L L H L L L L L L L L L L L L L 1 L L L L H L L L L L L L L L L L L L L 2 L3… L60 H H H H L H L L L L L L L L L L L L L61 Dark Light H H H H H L L L L L L L L L L L L L L62 Gray Scale of Red Red H H H H H H L L L L L L L L L L L L Red L63 Black L L L L L L L L L L L L L L L L L L L 0 L L L L L L L L L L L H L L L L L L L 1 L L L L L L L L L L H L L L L L L L L 2 L3… L60 L L L L L L H H H H L H L L L L L L L61 Dark Light L L L L L L H H H H H L L L L L L L L62 Gray Scale of Green Green L L L L L L H H H H H H L L L L L L Green L63 Black L L L L L L L L L L L L L L L L L L L 0 L L L L L L L L L L L L L L L L L H L 1 L L L L L L L L L L L L L L L L H L L 2 L3… L60 L L L L L L L L L L L L H H H H L H L61 Dark Light L L L L L L L L L L L L H H H H H L L62 Gray Scale of Blue Blue L L L L L L L L L L L L H H H H H H Blue L63 Black L L L L L L L L L L L L L L L L L L L 0 L L L L L H L L L L L H L L L L L H L 1 L L L L H L L L L L H L L L L L H L L 2 L3… L60 H H H H L H H H H H L H H H H H L H L61 Dark Light H H H H H L H H H H H L H H H H H L L62 Gray Scale of White & Black White H H H H H H H H H H H H H H H H H H White L63
1) The module should be driven and inspected under normal test conditions. 2) The module should not have condensation of water (moistur e) on the module. 3) The module should be inspected after two or more hours storage in normal conditions (15 - 35 °C,45 - 65%(RH)). 4) A module shall be used only for one test. SPECIFICATIONS The module shall have no failure in t he following reliability test items. Test Item Test Conditions Result High Temperature Operation 1) 65 °C 192 h OK High Temperature Storage 2) 80 °C 192 h OK High Temperature High Humidity operation 1) 50 °C 80% 192 h OK Low Temperatur e Operation 1) - 10 °C 192 h OK Low Temperature Storage 2) - 20 °C 192 h OK Temperature Shock 2) - 20 °C ⇔ 80 °C 0.5h 0.5h 50 cycles OK Mechanical Vibration 2) 10 - 200 - 10Hz sweep/cycle, 1.5 × 9.8m/s 2 cons tant, X.Y.Z each directions, 0.5h each OK Mechanical Shock 2) 50 × 9.8m/s 2 , 20ms, ±X, ±Y, ±Z direction, one time each OK Note 1) Operating Note 2) Non - Operating Definitions of failure for judgment shall be as follows: 1) Function of the module should be maintained. 2) Current consumption should be smaller than the specified value. 3) Appearance and display quality should not have distinguished degradation. 4) Luminance should be larger th an 50% of the minimum value specified in OPTICAL SPECIFICATION.
LCD module is generally designed with precise parts to achieve light weighted thin mechanical dimensions. In using our Modules, make certain that you fully understand and put into practice the warnings and safety precautions detailed in Eng ineering Information No.EE - N001,"CAUTIONS AND INSTRUCTIONS FOR TOSHIBA LCD MODULES". Refer to individual specifications and TECHNICAL DATA sheets (hereinafter called "TD") for more detailed technical information. 1) SPECIAL PURPOSES A) Toshiba Matsushita Di splay Technology's Standard LCD Modules have not been customized for operation in extreme environments or for use in applications where performance failures could be life - threatening or otherwise catastrophic. B) Since Toshiba Matsushita Display Technolog y's Standard LCD Modules have not been designed for operation in extreme environments, they must never be used in devices that will be exposed to abnormally high levels of vibration or shock which exceed Toshiba Matsushita Display Technology's published sp ecification limits. C) In addition, since Toshiba Matsushita Display Technology Standard LCD Modules have not been designed for use in applications where performance failures could be life - threatening or catastrophic, they must never be installed in aircr aft navigation control systems (such as, but not limited to Traffic Collision Avoidance System and Air Traffic Indicator), in military defense or weapons systems, in critical industrial process - control systems (e.g., those involved in the production of nuc lear energy), or in critical medical device or patient life - support systems. 2) DISASSEMBLING OR MODIFICATION DO NOT DISASSEMBLE OR MODIFY the module. It may damage sensitive parts inside LCD module, and may cause scratches or dust on the display. Toshiba Ma tsushita Display Technology doses not warrant the module, if customer disassembled or modified it. 3) BREAKAGE OF LCD PANEL DO NOT INGEST liquid crystal material, DO NOT INHALE this material, and DO NOT CONTACT the material with skin, if LCD panel is broken and liquid crystal material spills out. If liquid crystal material comes into mouth or eyes, rinse mouth or eyes out with water immediately. If this material contact with skin or cloths, wash it off immediately with alcohol and rinse thoroughly with water. 4) GLASS OF LCD PANEL BE CAREFUL WITH CHIPS OF GLASS that may cause injuring fingers or skin, when the glass is broken. 5) ELECTRIC SHOCK DISCONNECT POWER SUPPLY before handling LCD module. DO NOT TOUCH the parts inside LCD module and the fluorescent lamp's c onnector or cables in order to prevent electric shock, because high voltage is supplied to these parts from the inverter unit while power supply is turned on. 6) ABSOLUTE MAXIMUM RATINGS AND POWER PROTECTION CIRCUIT DO NOT EXCEED the absolute maximum rating values under the worst probable conditions caused by the supply voltage variation, input voltage variation, variation in parts' constants, environmental temperature, etc., otherwise LCD module may be damaged. Employ protection circuit for power supply, whe never the specification or TD specifies it. Suitable protection circuit should be applied for each system design. 7) RECOMMENDED OPERATION CONDITIONS The performance and quality of the LCD panel are warranted only when the LCD panel is used withi n “ the recommended operation conditions ” . Toshiba Matsushita Display Technology Co., Ltd. never warrants the performance and quality of the LCD panel when you use the LCD panel over “ the recommended operation conditions ” , although within “the absolute maxi mum rating”. To use the LCD panel over “ the recommended operation conditions ” may have bad influence on the characteristics and reliability of the LCD panel and may shorten the life of the LCD panel . Therefore, when designing the whole set, not to be over “ the recommended operation conditions ” , you should fully take care of supply voltage change , characteristic of connection parts, serge of input - and - output line, and surrounding temperature. 8) DISPOSAL When dispose LCD module, obey to the applicable environm ental regulations.