LSP05GI240PX3316 LITTELFUSE | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
Features
- Outdoor and Commercial LED Lighting
- Roadway lighting
- Traffic lighting
- Digital signage
- Wall wash lighting
- Parking garage lighting
- Flood lighting
- Tunnel lighting
- Street lighting Agency Standard Agency File Number UL 1449+ E320116 IEC 61643-11++ NL -40819 EN 61643-11++ 3177948.01 + = For 120V , 240V and 277V ++ = For 240V and 277V Littelfuse’s LSP05GI thermally protected Surge Protective Device is a self-protected device specially designed to be used in outdoor and commercial LED lighting fixtures for transient overvoltage protection. It has been developed with Littelfuse’s thermally protected varistor technology. Its built-in thermal disconnect function provides additional protection to prevent catastrophic failure and fire hazard even under extreme circumstances of varistor end-of-life or sustaining over voltage conditions. The LSP05GI features a built-in LED indicator that notifies when replacement of the module is needed.
- Build-in LED Indication, saves maintenance time by identifying replacement need
- Thermally Protected
- Suitable for use in luminaire with Class I or Class II insulation*
- 10kA Maximum Discharge Current (Imax), 8/20µs
- Meets ANSI C82.77-5-2015: Location C Medium
- Meets ANSI C136.2-2015: Enhanced Level
- Meets IEEE C62.41 .2: Location Category C Low
- Meets US Dept. of Energy MSSSLC Model Spec.
- High line-to-earth/ground resistance
- IP66: Dust-tight and water resistant
- Parallel or Series connected options
- UL 1449 and IEC 61643-11/EN 61643-11 recognized* * See ‘Part Numbering System’ for exact details of voltages available for Class I and Class II installations, and ‘Device Ratings and Specifications’ table for voltage specific approvals. Additional Information Datasheet Samples Resources
LED Lighting Surge Protection Module > LSP05GI © 2018 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 08/22/18 * = S or P † = Module with ‘H’ designation features 1500Vac Hi-Pot withstand capability in common mode (L -G and N-G). Glossary: 2. Maximum Discharge Current Imax (A): The maximum discharge current is a measure of the SPDs maximum capability; single impulse of discharge current uses the 8/20µs current waveform. All Devices pass maximum discharge current with possible, safe opening of thermal disconnect. 3. Nominal Discharge Current In (A): The nominal discharge current is a measure of the SPDs endurance capability; 15 impulses of discharge current uses the 8/20µs current waveform. 4. MLV: UL1449 Measured limiting voltage; the highest value of residual voltage measurements during the application of impulses of 8/20µs nominal discharge current (In); an average voltage value of 15 impulses. 5. Up: IEC 61643-11 Voltage protection level; the highest value of residual voltage measurements during the application of impulses of 8/20µs nominal discharge current (In); a rounding voltage value of maximum measurement. LSP05GI Series Device Ratings and Specifications Part Number Operating Voltage (VAC) MCOV/UC 1 (VAC) Maximum Discharge Current 2 Imax (A) Nominal Discharge Current 3 In (A) MLV 4 (V) Up (V) Safety Compliance IEC/EN 61643-1 1 UL1449 LSP05GI120* 120 150 10,000 5,000 L -N:650 L -G:1280 N-G:1230 -- -- X LSP05GI240* 240 275 10,000 5,000 L -N:1080 L -G:1230 N-G:1340 L -N: 1300 L -G/PE: 2400 N-G/PE: 2200 X X LSP05GI277* 277 320 10,000 5,000 L -N: 1260 L -G: 1260 N-G:1300 L -N: 1400 L -G/PE: 2400 N-G/PE: 2200 X X LSP05GI347* 347 420 10,000 5,000 L -N: 1530 L -G: 1550 N-G: 1410 -- -- -- LSP05GI480* 480 510 10,000 5,000 L -N: 1800 L -G: 1900 N-G: 1410 -- -- -- LSP05GI120*H† 120 150 10,000 5,000 L -N: 650 L -G: 3150 N-G: 3210 -- -- X LSP05GI240*H† 240 275 10,000 5,000 L -N: 1080 L -G: 3170 N-G: 3430 -- -- X LSP05GI277*H† 277 320 10,000 5,000 L -N: 1260 L -G: 3160 N-G: 3310 -- -- X LSP05GI480*H† 480 510 10,000 5,000 L -N: 1800 L -G: 3090 N-G: 3090 -- -- -- Absolute Maximum Ratings
- For ratings of individual members of a series, see Device Ratings and Specifications chart CAUTION: Stresses above those listed in ‘Absolute Maximum Ratings’ may cause permanent damage to the device. This is a stress only rating and operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. LSP05GI Series Units Continuous: Steady State Applied Voltage: Max AC Voltage Range (VM(AC)RMS) 150 to 510 V Continuous Current 3.5 A Transient: Maximum Discharge Current, 8/20μs Waveform (Imax) 10,000 A Nominal Discharge Current, 8/20µs Waveform (In) 5,000 A Operating Ambient Temperature Range (TA) -40 to +85 °C Storage Temperature Range (TSTG) -40 to +85 °C Isolation Voltage Capability (When the thermal disconnect opens) 600 V Insulation Resistance >1,000 MΩ
LED Lighting Surge Protection Module > LSP05GI © 2018 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 08/22/18 Specification Value Condition 240V 277V Temporary Overvoltage (V) TOV UT @ tT = 5 s 337 403 LV System Fault for TN Power Grid Temporary Overvoltage (V) TOV UT @ tT = 120 min 442 529 LV System Fault for TN Power Grid Power grids TN TN Backup fuse (A) 16 20 Maximum gG Fuse End of life indication Ye s Ye s Optical Light ON: SPD is functional Light OFF: SPD has reached end-of-life Max earth leakage current at Uc (μA) 50 50 IEC 61643-11 Test Classification Test Class II and III Test Class II and III EN 61643-11 Type Classification Type 2 and 3 Type 2 and 3 UL 1449 Type 4CA 4CA LSP05GI Series Wire Specification Part Number Extension Length Diameter Double Insulation Installation Class Color X3333 250mm ± 20mm 1mm2 Ye s I L - Brown N - Blue G/PE - Green with Y ellow stripe X3316 250mm ± 20mm 1mm2 Ye s II L - Brown N - Blue None 250mm ± 20mm 16AWG Ye s -- L - Black N- White G- Green Repetitive Surge Capability Pulse Rating (8x20µSec) Strikes Surge 1 10,000A 2 7 ,000A 15 5,000A 100 1,500A 1,000 700A 10000 1000 100 10 1001 000 10000 IMPULSE DURATION (/uni03BCs) SURGE CURRENT (A) MODEL SIZE = 20MM TA = -55oC TO 85oC 100000 104 105 106 102 103 130 to 625VM(AC) RATING 500+20
LED Lighting Surge Protection Module > LSP05GI © 2018 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 08/22/18 Part Numbering SystemApplication/Installation Schematic LSP 05G I 120 P H Xxxxx Littelfuse Surge Protection Module 5kA (Nominal Discharge Current) Operating Voltage Built-in LED indication P: Parallel connection S: Series connection Blank: Normal mode H: With 1500Vac Hi-Pot withstand capability in common mode (L-G and N-G) X3316: without GND wire connection, available for 240Vac and 277Vac rating with CE Marking for Class II unearthed luminaire installation Wire Color: Line: Brown, Neutral: Blue Other Options: X3333: with GND wire connection, avail- able for 240Vac and 277Vac rating with CE Marking for Class I earthed luminaire installation Wire Color: Line: Brown, Neutral: Blue, Ground/PE: Green with yellow stripe Note: Green LED light on: SPD is good Green LED light off: SPD needs replacement G/PE AC/DC Power Supply L N Parallel Connection L N G/PE SPD X3333 AC/DC Power Supply L N G/PE Series Connection L N G/PE L N G/PE L N G/PE L N Series Connection (for Class II Unearthed) AC/DC Power Supply L N Parallel Connection (for Class II Unearthed) AC/DC Power Supply SPD X3333 SPD X3316 SPD X3316 Dimensions Series Version Parallel Version Note: Dimensions are in millimeters (mm) 26.02 ±1.50 LED Indication 47.69 ±2.00 Ø6.40±0.30 56.76 ±2.00 250±20 46±8 6±2 46.36±2.00 17.48±1.50 26.00 ±1.50 47.69 ±2.00 17.48 ±1.50Ø6.40±0.30 Output Input LED Indication 250±20 46±8 6±2 56.76 ±2.00 250±20 46±8 6±2 46.36 ±2.00