LS4000 POWER-ONE | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 27
Technical content
Cassette Style 100 Watt AC-DC Converters S Series PFC Edition 01/01.2001 1/27
100 Watt AC-DC Converters with PFC S Series
- Universal input voltage range
- Power factor >0.95, harmonics <IEC/EN 61000-3-2
- Input over- and undervoltage lock-out
- Efficient input filter and built-in surge and transient suppression circuitry
- Fully isolated outputs
- Outputs overload, open- and short-circuit proof
- No derating over entire operating temperature range Safety according to IEC/EN 60950 Table of Contents Page Summary The S 4000/S 5000 series of AC-DC converters represents a flexible range of power supplies for use in advanced elec- tronic systems. Features include full power factor correc- tion, high efficiency, high reliability, low output voltage noise and excellent dynamic response to load/line changes. The converter inputs are protected against surges and tran- sients occurring at the source lines. An input over- and undervoltage lock-out circuitry disables the outputs if the input voltage is outside the specified range. Inrush current limitation is included preventing circuit breakers and fuses from being damaged at switch-on. All outputs are overload, open- and short-circuit proof and are protected against overvoltages by means of a built-in suppressor diode. The outputs can be inhibited by a logic signal applied to the connector pin 18 (i). If the inhibit func- tion is not used pin 18 must be connected to pin 14 to en- able the outputs. LED indicators display the status of the converter and allow visual monitoring of the system at any time. Full input to output, input to case, output to case and output to output isolation is provided. The modules are designed and built according to the international safety standards IEC/EN 60950 and have been approved by the safety agencies LGA (Germany) and UL (USA). The UL Mark for Canada has been officially recognized by regulatory au- thorities in provinces across Canada. The case design allows operation at nominal load up to 71°C in a free air ambient temperature. If forced cooling is provided, the ambient temperature may exceed 71 °C but the case temperature must remain below 95 °C under all conditions. A temperature sensor generates an inhibit signal which disables the outputs if the case temperature TC exceeds the limit. The outputs are automatically re-enabled when the temperature drops below the limit. Various options are available to adapt the converters to in- dividual applications. The modules may either be plugged into 19" rack systems according to DIN 41494, or be chassis mounted. Important: These products are intended to replace the LS 1000 and LS 2000 in order to comply with IEC/EN 61000-3-2. Page 168 6.6" 2.4" 12 TE 111 4.4" 3 U LGA Input voltage range from 85...264 V AC 1 or 2 isolated outputs up to 48 V DC 4 kV AC I/O electric strength test voltage
Cassette Style 100 Watt AC-DC Converters S Series PFC Edition 01/01.2001 2/27 Type Survey and Key Data Non standard input/output configuration or special custom adaptions are available on request. See also: Commercial Infor- mation: Inquiry Form for Customized Power Supply. Table 1: Type survey LS Output 1 Output 2 Input Voltage Range Efficiency 1 Options Uo nom Io nom Uo nom Io nom Ui min...Ui max hmin 5.1 16.0 LS 4001-7R 77 -9 12.0 8.0 LS 4301-7R 81 E 15.0 6.5 LS 4501-7R 83 D 24.0 4.2 LS 4601-7R 83 V 24.0 3 4.0 LS 5320-7R 81 P 30.0 3 3.2 LS 5540-7R 81 T 48.0 3 2.0 LS 5660-7R 81 B1 12.0 4.0 12.0 4 4.0 LS 5320-7R 81 15.0 3.2 15.0 4 3.2 LS 5540-7R 81 24.0 2.0 24.0 4 2.0 LS 5660-7R 81 Type Key Type Key L S 5 5 40 -7 E R P D V T B1 Number of outputs (4 for single, 5 for double outputs) 4...5 Single output units: Nominal voltage output 1 (main output), Uo1 nom Symmetrical double output units: Nominal voltage output 1/output 2, Uo1/2 nom Operational ambient temperature range TA: Auxiliary functions and options: Potentiometer (output voltage adjustment) .. P2 Save data signal (D0...DD, to be specified) D 3 1 External wiring of main and second output depending upon the desired output configuration (see: R-Function for different output con- figurations). 2 Feature R excludes option P and vice versa. 3 Option D excludes option V and vice versa. 4 Option V available for LS 4000 types with 5V output. 1 Efficiency at Ui nom and Io nom.
2 If the output voltages are increased above Uo nom via R-input
control, option P setting, remote sensing or option T, the output currents must be reduced accordingly so that Po nom is not ex- ceeded.
3 Series connection of output 1 and 2, see: R-Function for differ-
ent output configurations. 4 Second output semi-regulated. 5 Option V for LS 4000 types with 5 V outputs. 6 For DC-input please ask your local Power-One partner.
Cassette Style 100 Watt AC-DC Converters S Series PFC Edition 01/01.2001 3/27 Functional Description The input voltage is fed via an input fuse, an input filter, a rectifier and an inrush current limiter to a single transistor boost converter. This converter provides a sinusoidal input current (IEC/EN 61000-3-2, class D equipment) and sour- ces a capacitor with a voltage of 360-370 V DC. This ca- pacitor sources a single transistor forward converter. Each output is powered by a separate secondary winding of the main transformer. The resultant voltages are rectified and their ripples smoothed by a power choke and an output filter. The control logic senses the main output voltage Uo1 and generates, with respect to the maximum admissible output currents, the control signal for the primary switching transistor. The second output of double output units is controlled by the main output, but has independent current limiting. If the main output is driven into current limitation, the second out- put voltage will fall as well and vice versa. Input filter Control circuit P Y Y Output filter – + Y Y Forward converter (approx. 80 kHz) Boost converter (PFC)
360 V DC
R i D/V T Vo+ Vo– 26N∼ Fig. 1 Block diagram of single output converters LS 4000 Input filter Control circuit P Output 2 filter Output 1 filter – + Y Y Y Y Y Y Forward converter (approx. 80 kHz) Boost converter (PFC) +360 V DC Ci 03002 R i D T Vo1+ Vo1– Vo2+ Vo2– Fig. 2 Block diagram of symmetrical double output converters LS 5000
1 Transient suppressor (VDR)
2 Inrush current limiter (NTC or Opt. E), -9 versions exclude the NTC
3 Input fuse
4 Hold-up capacitor
Cassette Style 100 Watt AC-DC Converters S Series PFC Edition 01/01.2001 4/27 Rs ext Ri RNTCIinr p Ui rms Ci 04001 Input Under-/Overvoltage Lock-out If the input voltage remains below approx. 65 V AC or ex- ceeds approx. 280 V AC an internally generated inhibit sig- nal disables the output(s). When checking this function the absolute maximum input voltage rating Ui abs should be considered! Between Ui min and the undervoltage lock-out level the output voltage may be below the value defined in table: Output data (see: Technical Information: Measuring and Testing). Input Transient Protection A VDR together with the input fuse and a symmetrical input filter form an effective protection against high input tran- sient voltages. Input Fuse A fuse mounted inside the converter protects the module against severe defects. (If operated from a DC-source this fuse may not fully protect the module when the input volt- age exceeds 200 V DC! In applications where the convert- ers operate at source voltages above 200 V DC an external fuse or a circuit breaker at system level should be installed!) Table 3: Fuse Specification Module Fuse type Fuse rating LS 1 slow-blow SP T 4 A, 250 V
1 Fuse size 5 × 20 mm
Fig. 3 Equivalent circuit diagram for input impedance. Electrical Input Data General Conditions – TA = 25°C, unless TC is specified. – Pin 18 connected to pin 14, Uo adjusted to Uo nom (option P); R input not connected. – Sense line pins S+ and S– connected to Vo+ and Vo– respectively. Table 2: Input data Input LS Characteristics Conditions min typ max Unit Ui Operating Input voltage Io = 0...Io nom 85 255 V AC 3,4 Ui nom Nominal Input voltage TC min...TC max 230 Ii Input current Ui nom, Io nom 1 0.55 A rms Pi0 No-load input power Ui min…Ui max 9.0 10 W Pi inh Idle input power unit inhibited 3.5 5 Ri Input resistance TC = 25°C 480 m Ω RNTC NTC resistance 2 3200 4000 Ci Input capacitance 80 100 120 µF Ui RFI Conducted input RFI EN 55022 B Radiated input RFI Ui nom, Io nom B Ui abs Input voltage limits –400 400 V DC without damage –400 400 V p 1 With double output modules, both outputs loaded with Io nom. 2 Valid for -7 versions with NTC, (-9 versions exclude the NTC). Initial switch-on cycle. Subsequent switch-on/off cycles increase the in- rush current peak value. 3 AC frequency range 47...63 Hz. 4 For DC-input please ask your local Power-One partner. Reverse Polarity Protection Should the input voltage to the unit be supplied from a DC source the built-in bridge rectifier provides reverse polarity protection. (For DC-input operation, please consult your lo- cal Power-One partner.) Inrush Current Limitation The modules of the versions -7, incorporate an NTC resis- tor in the input circuitry which – at initial turn on – reduces the peak inrush current value by a factor of 5...10 to protect connectors and switching devices from damage. Subse- quent switch-on cycles within short periods will cause an increase of the peak inrush current value due to the warm- ing-up of the NTC resistor. See also: E option. Inrush Current Peak Value The inrush current peak value (initial switch-on cycle) can be determined by following calculation:
Cassette Style 100 Watt AC-DC Converters S Series PFC Edition 01/01.2001 5/27 100 150 200 250 30050 0.5 1.5 2.5 li [Arms] Ui [V AC] 04005 0.2 0.4 0.6 0.8 10 0.7 0.75 0.8 0.85 0.9 0.95 Power Factor Io/Io nom Ui = 230 V AC Ui = 85 V AC 04004 3 5 7 9 11 13 17 19 15 Harm. 3.0 2.5 2.0 1.5 1.0 0.5 Ii [mA/W] 3.5 04042 Limit class D according to IEC/EN 61000-3-2 Fig. 6 Input current versus input voltage at Io nom Fig. 5 Harmonic currents at the input, IEC/EN 61000-3-2, class D. Ui = Ui nom, Io = Io nom. Fig. 7 Power factor versus output current at Ui 230 V AC and 85 V AC. Static Input current Characteristic Harmonic Currents The harmonic distortion is well below the limits specified in IEC/EN 61000-3-2, class D. 1 23 t [ms] 100 Iinr [A] 130 Ui = 255 Vrms Ui = 115 Vrms 04006 Input Inrush Current Characteristic Fig. 4 Theoretical input inrush current versus time at Ui 255 Vrms and 115 Vrms, Rext = 0. Power Factor, Harmonics Power factor correction is achieved by controlling the input current waveform synchronously with the input voltage waveform. The power factor control is active under all oper- ating conditions.
Cassette Style 100 Watt AC-DC Converters S Series PFC Edition 01/01.2001 6/27 Electrical Output Data General Conditions – TA = 25°C, unless TC is specified. – Pin 18 (i) connected to pin 14 (S–/Vo1–), Uo adjusted to Uo nom (option P), R input not connected. – Sense line pins 12 (S+) and 14 (S–) connected to pins 4 (Vo1+) and 8 (Vo1–) respectively. Table 4a: Output data single output modules Output LS 4001 LS 4301 LS 4501 LS 4601 5.1 V 12.0 V 15.0 V 24.0 V Characteristics Conditions min typ max min typ max min typ max min typ max Unit Uop Overvoltage protection 7.6 21 26.5 43.5 (supressor diode) TC min...TC max uo 5 Output Low frequency Ui nom, Io nom 2222 m V pp voltage Switching freq. IEC/EN 61204 15 5 5 5noise Total BW = 20 MHz 50 40 40 40 DUo U Static line regulation Ui min...Ui nom, ±5 ±12 ±15 ±24 mV Ui nom...Ui max, Io nom DUo I Static load regulation Ui nom, Io = 2 02 43 0 4 8 (0.1...1) Io nom uo d 3 Dynamic Voltage Ui nom, Io = ±170 ±150 ±150 ±100 load deviation Io nom ↔ 1/2 Io nom of output voltage 4 0...Io nom 1 If the output voltages are increased above Uo nom through R-input control, option P setting, remote sensing or option T, the output cur- rents should be reduced accordingly so that Po nom is not exceeded. 2 See: Output Voltage Regulation of Single or Double Output Modules with Outputs 1 and 2 Connected in Series. 3 See: Typical dynamic load regulation of Uo1 and Uo2. 4 Negative temperature coefficient (0...–3 mV/cell and K) available on request. 5 Measured according to IEC/EN 61204 sub clause 3.10 with a probe acc. to annex A of the same standards. (See:Technical Informa- tion: Measuring and Testing)
Cassette Style 100 Watt AC-DC Converters S Series PFC Edition 01/01.2001 7/27 Table 4b: Output data double output modules Output LS 5320 LS 5540 LS 5660 (Outputs connected in Series) 24 V (2 × 12 V) 30 V (2 × 15 V) 48 V (2 × 24 V) Characteristics Conditions min typ max min typ max min typ max Unit Uo Output voltage 2 Ui nom, Io nom 24.0 30.0 48.0 V Uop Overvoltage protection 38 48 74 (supressor diode) TC min...TC max uo 7 Output Low frequency Ui nom, Io nom 33 5 m V pp voltage Switching freq. IEC/EN 61204 15 15 20noise 3 Total BW = 20 MHz 100 100 150 DUo U Static line regulation Ui min...Ui max ±12 ±15 ±24 mV Io nom DUo I Static load regulation Ui nom, Io =4 0 6 0 9 6 (0.1...1) Io nom uo d 5 Dynamic Voltage Ui nom, Io = ±250 ±200 ±150 load deviation Io nom ↔ 1/2 Io nom t d 5 regulat. Recovery time IEC/EN 61204 0.3 0.3 0.3 ms of output voltage 6 0...Io nom 1 If the output voltages are increased above Uo nom through R-input control, option P setting, remote sensing or option T, the output cur- rents should be reduced accordingly so that Po nom is not exceeded. 2 Series connection for Uo nom = 24 V, 30 V or 48 V, see: R-Function for different output configurations. 3 Shortest possible wiring for series connection at the connector. 4 See: Output Voltage Regulation of Single or Double Output Modules with Outputs 1 and 2 Connected in Series. 5 See: Typical dynamic load regulation of Uo1 and Uo2. 6 Negative temperature coefficient (0...-3 mV/cell and K) available on request. 7 Measured according to IEC/EN 61204 sub clause 3.10 with a probe acc. to annex A of the same standards. (See:Technical Informa- tion: Measuring and Testing)
Cassette Style 100 Watt AC-DC Converters S Series PFC Edition 01/01.2001 8/27 Table 4c: Output data double output modules Output LS 5320 LS 5540 (Outputs independently loaded) 1 12 V/12 V 15 V/15 V Characteristics Conditions Output 1 Output 2 Output 1 Output 2 min typ max min typ max min typ max min typ max Unit Uop Overvoltage protection 19 19 24 24 (supressor diode) TC min...TC max uo 8 Output Low frequency Ui nom, Io nom 3333 m V pp voltage Switching freq. IEC/EN 61204 12 12 10 10noise Total BW = 20 MHz 80 40 100 40 DUo U Static line regulation Ui min...Ui nom ±12 ±12 ±15 ±15 mV Ui nom...Ui max Io nom DUo I Static load regulation Ui nom, Io =4 8 5 60 5 (0.1...1) Io nom 5 uo d 6 Dynamic Voltage Ui nom, Io = ±100 ±100 load deviation Io nom ↔ 1/2 Io nom t d 6 regulat. Recovery time IEC/EN 61204 0.3 0.3 ms of output voltage 7 0...Io nom Table 4d: Output data double output modules Output LS 5660 (Outputs independently loaded) 1 24 V/24 V Characteristics Conditions Output 1 Output 2 min typ max min typ max Unit Uo Output voltage Ui nom, Io nom 2 23.86 24.14 23.64 24.36 V Uop Overvoltage protection 37 37 (supressor diode) TC min...TC max uo 8 Output Low frequency Ui nom, Io nom 33 m V pp voltage Switching freq. IEC/EN 61204 10 10noise Total BW = 20 MHz 100 40 DUo U Static line regulation Ui min...Ui nom, ±24 ±24 mV Ui nom...Ui max, Io nom DUo I Static load regulation Ui nom, Io =9 6 5 (0.1...1) Io nom 5 uo d 6 Dynamic Voltage Ui nom, Io = ±80 load deviation Io nom ↔ 1/2 Io nom t d 6 regulat. Recovery time IEC/EN 61204 0.3 ms aUo Temperature coefficient Ui min...Ui max –0.5 mV/K of output voltage 7 0...Io nom
1 Depending upon the desired out-
put configuration the wiring should be made as shown in: R-Function for different output configurations. 2 Same conditions for both outputs.
3 If the control voltages are in-
control, option Psetting, remote sensing or option T, the output currentsshould be reduced ac- cordingly so that Po nom is not ex- ceeded.
4 See: Output Voltage Regulation of
Single or Double Output Modules with Outputs 1 and 2 Connected in Series. 5 Condition for specified output. Other output loaded with constant current Io = Io nom. See: Output voltage regulation of double out- put units.
6 See: Typical dynamic load regula-
tion of Uo1 and Uo2.
7 Negative temperature coefficient
(0....–3 mV/cell and K) available on request.
8 Measured according to IEC/EN
61204 sub clause 3.10 with a probe acc. to annex A of the same standards.
Cassette Style 100 Watt AC-DC Converters S Series PFC Edition 01/01.2001 9/27 Output Voltage Regulation of Double Output Modules Output 1 is under normal conditions regulated to Uo1 nom, independent of the output currents. Uo2 is dependent upon the load distribution. If both outputs are loaded with more than 10% of Io nom, the deviation of Uo2 remains within ±5% of the value of Uo1. The following 3 figures show the regulation with varying load distribution. If Io1 = Io2 or the two outputs are connected in series, the de- viation of Uo2 remains within ±1% of the value of Uo1 pro- vided that a total load of more than 10% of Io nom is applied. Two outputs of a single S 5000 module connected in paral- lel will behave like the output of a S 4000 module; the paral- leled output is fully regulated. No precautions are neces- sary in using the R-input and the test sockets. Uo Uo nom 0.98 0.5 0.5 1.0 Io1 IoL Io Io nom 05001 Fig. 9 Uo1 vs. Io1 (typ.) of single output units Thermal Considerations If a converter is located in free, quasi-stationary air (con- vection cooling) at the indicated maximum ambient tem- perature TA max (see table: Temperature specifications) and is operated at its nominal input voltage and output power, the temperature measured at the Measuring point of case temperature TC (see: Mechanical Data) will approach the indicated value TC max after the warm-up phase. However, the relationship between TA and TC depends heavily on the conditions of operation and integration into a system. The thermal conditions are influenced by input voltage, output current, airflow and temperature of surrounding compo- nents and surfaces. TA max is therefore, contrary to TC max, an indicative value only. Caution: The installer must ensure that under all operat- ing conditions TC remains within the limits stated in the table: Temperature specifications. Notes: Sufficient forced cooling or an additional heat sink allows TA to be higher than 71°C (e.g. 85°C) if TC max is not exceeded. For -7 or -9 units at an ambient temperature TA of 85°C with only convection cooling, the maximum permissible current for each output is approx. 40% of its nominal value as per figure. 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 50 60 70 80 90 100 I o/Io nom TA [°C] 0.9 1.0 Forced cooling 05089 TA min TC max Convection cooling Fig. 8 Output current derating versus temperature for -7 and -9 units. Thermal Protection A temperature sensor generates an internal inhibit signal which disables the outputs if the case temperature exceeds TC max. The outputs are automatically re-enabled if the tem- perature drops below this limit. It is recommended that continuous operation under simul- taneous extreme worst case conditions of the following three parameters be avoided: Minimum input voltage, maximum output power and maximum temperature. Output Protection Each output is protected against overvoltage which could occur due to a failure of the control circuit by means of a voltage suppressor diode which, under worst case condi- tions, may become a short circuit. The suppressor diodes are not designed to withstand externally applied over- voltages. Overload at any of the two outputs will cause a shut-down of both outputs. A red LED indicates the over- load condition. Parallel or Series Connection of Units Single or double output units with equal nominal output volt- age can be connected in parallel without any precautions using option T. With option T (current sharing), all units share the current approximately equally. Single output units and/or main and second outputs of dou- ble output units can be connected in series with any other (similar) output. Note: – Parallel connection of double output units should always include both, main and second output to maintain good regulation of both outputs. – Not more than 5 units should be connected in parallel. – Series connection of second outputs without involving their main outputs should be avoided as regulation may be poor. – The maximum output current is limited by the output with the lowest current limitation if several outputs are con- nected in series. Output Voltage Regulation of Single or Double Output Modules with Outputs 1 and 2 Connected in Series
Cassette Style 100 Watt AC-DC Converters S Series PFC Edition 01/01.2001 10/27 Switching Frequency versus Load 0.2 0.4 0.6 0.8 10 Frequency [kHz] load [I o/Io nom] 1.2 05008 Fig. 13 Switching frequency versus load. (The boost converter at the input stage has a fixed frequency of 100 kHz) 0 0.2 0.4 0.6 0.8 1 Io2/Io2 nom 13.5 14.5 15.5 [V] Uo2 Io1 = 100% Io1 =5 0 % Io1 =1 0 % 16.5 05084
01 Io2/Io2 nom
10.5 11.5 12.0 12.5 [V] U Io1 =100% Io1 =5 0 % Io1 =1 0 % 0.2 0.4 0.6 0.8 05083 Fig. 10 LS 5320: DUo2 (typ.) vs. Io2 with different Io1. Fig. 11 LS 5540: DUo2 (typ.) vs. Io2 with different Io1. 00 . 2 0.4 0.6 0.8 1 Io2/Io2 nom [V] U Io1 = 100% Io1 =5 0 % Io1 =1 0 % 05085 Fig. 12 LS 5660: DUo2 (typ.) vs. Io2 with different Io1. Uo2d Uo1d Uo1d td td Ur Ur t t t <10 µs <10 µs Uo1 Uo2 Io1/Io1 nom 0.5 1Io2/Io2 nom 05005 Fig. 14 Typical dynamic load regulation of Uo1 and Uo2. Dynamic Load Regulation Hold-up Time versus Output Power 0.2 0.4 0.6 0.8 10 160 100 120 140 time [ms] 180 Io /Io nom 05013 Fig. 15 Hold-up time th versus output power. Efficiency versus Load 0.2 0.4 0.6 0.8 10 0.90 0.30 0.40 0.50 0.60 0.70 0.80 Efficiency Io/Io nom Ui = 230 V AC Ui = 85 V AC 05014 Fig. 16 Efficiency versus load at Ui; 230 V AC and 85 V AC
Cassette Style 100 Watt AC-DC Converters S Series PFC Edition 01/01.2001 11/27 0 t Inhibit 0.1 Uo/Uo nom tr tf 06001 Fig. 19 Output response as a function of inhibit control Auxiliary Functions i Inhibit for Remote On and Off Note: With open i input: Output is disabled (Uo = off). The outputs of the module may be enabled or disabled by means of a logic signal (TTL, CMOS, etc.) applied between the inhibit input i and the negative pin of output 1 (Vo1–). In systems with several units, this feature can be used, for ex- ample, to control the activation sequence of the converters. If the inhibit function is not required, connect the inhibit pin 18 to pin 14 to enable the outputs (active low logic, fail safe). For output response refer to: Hold-up Time and Out- put Response. Vi+ Vi– Vo– i Vo+ Iinh Uinh 06031 1.6 0.8 –0.8 –50 Uinh [V] Iinh [mA] –30 0 –10 10 30 50 2.0 1.2 0.4 –0.4 Uinh = 0.8 V Uo = on Uo = off Uinh = 2.4 V 06032 Fig. 17 Definition of Uinh and Iinh. Fig. 18 Typical inhibit current Iinh versus inhibit voltage Uinh Table 5: Inhibit characteristics Characteristic Conditions min typ max Unit Uinh Inhibit Uo = on Ui min…Ui max –50 0.8 V voltage Uo = off 2.4 50 Iinh Inhibit current Uinh = 0 –400 µA tr Rise time 30 ms tf Fall time depending on Io Sense Lines (Only for single output units 5.1 V, 12 V, 15 V, 24 V) This feature enables for compensation of voltage drops across the connector contacts and if necessary, across the load lines. If the sense lines are connected at the load rather than directly at the connector, the user should ensure that Uo max (between Vo1+ and Vo1–) is not exceeded. We recommend connecting the sense lines directly at the fe- male connector. For further information, please refer to: Application Notes . To ensure correct operation, both sense lines (S+ and S–) should be connected to their respective power outputs (Vo1+ and Vo1–) and the voltage difference between any sense line and its respective power output pin (as meas- ured on the connector) should not exceed the following val- ues: Table 6: Maximum Voltage compensation allowed using sense lines Output Total voltage difference Voltage difference voltage between sense lines and between their respective outputs Vo – and S– 5.1 V <0.5 V <0.25 V 12 V, 15 V <1.0 V <0.25 V If the output voltages are increased above Uo nom via R-in- put control, option P setting, remote sensing or option T, the output currents must be reduced accordingly so that Po nom is not exceeded. Important: The output terminals Vo1+ and Vo1 – must always be connected to the load before connecting the sense lines S+ and S –, otherwise the unit will be dam- aged.
Cassette Style 100 Watt AC-DC Converters S Series PFC Edition 01/01.2001 12/27 R Vo1+ Vo1– S– Uext N P Module Module Rext R'ext Vo1+ Vo1– N P R 06003 Programmable Output Voltage (R-Function) As a standard feature, the modules offer an adjustable out- put voltage, identi fied by letter R in the type designation. The control input R (pin 16) accepts either a control voltage Uext or a resistor Rext to adjust the desired output voltage. When not connected, the control input automatically sets the output voltage to Uo nom. a) Adjustment by means of an external control voltage Uext between pin 16 (R) and pin 14: The control voltage range is 0...2.75 V DC and allows an output voltage adjustment in the range of approximately 0...110% Uo nom. UoUext = –––––– • 2.5 V (approximate formula)Uo nom b) Adjustment by means of an external resistor: Depending upon the value of the required output voltage the resistor shall be connected either: Between pin 16 and pin 14 ( Uo < Uo nom ) to achieve an output voltage adjustment range of approxi- mately 0...100% Uo nom or: Between pin 16 and pin 12 ( Uo > Uo nom) to achieve an output voltage adjustment range of approximately 100...110% Uo nom. Warning: – Uext shall never exceed 2.75 V DC. – The value of R'ext shall never be less than the lowest value as indicated in table R'ext (for U0 >U0 nom) to avoid damage to the unit! Remarks: – The R-Function excludes option P (output voltage ad- justment by potentiometer). – If the output voltages are increased above Uo nom via R- input control, option P setting, remote sensing or option T, the output current(s) should be reduced accordingly so that Po nom is not exceeded. – The R-input (as well as option P) is related to the main output. – With double output units the second output follows the value of the controlled main output. Resistor values as indicated for the single output units should be used. – For correct output voltage adjustment of double output units the external wiring of the outputs should be accord- ing to fig.: R-Function for different output configuration depending upon the desired output configuration. – In case of parallel connection the output voltages should be individually set within a tolerance of 1...2%. Fig. 20 Output voltage control for single output units LS 4000 by means of the R input Table 7a: Rext for Uo < Uo nom; approximative values (Ui nom, Io nom, series E 96 resistors); R'ext = ∞ Uo nom = 5.1 V Uo nom = 12 V Uo nom = 15 V Uo nom = 24 V Uo (V) Rext [kΩ] Uo [V] 1 Rext [kΩ] Uo [V] 1 Rext [kΩ] Uo [V] 1 Rext [kΩ] 1.5 1.65 4 8 2 6 12 2.67 8 16 2 3.5 8.66 8 16 8.06 11 22 11 16 32 8.06 4.5 30.1 10 20 20 13 26 26.1 20 40 20 5.0 200 11 22 42.2 14 28 56.2 22 44 44.2 Table 7b: R’ext for Uo > Uo nom; approximative values (Ui nom, Io nom, series E 96 resistors); Rext = ∞ Uo nom = 5.1 V Uo nom = 12 V Uo nom = 15 V Uo nom = 24 V Uo [V] R'ext [kΩ] Uo [V] 1 R'ext [kΩ] Uo [V] 1 R'ext [kΩ] Uo [V] 1 R'ext [kΩ] 13.0 26.0 196 26.25 52.5 402 13.2 26.4 169 26.4 52.8 383 1 First column: single output units or double output units with separated outputs, second column: outputs in series connection
Cassette Style 100 Watt AC-DC Converters S Series PFC Edition 01/01.2001 13/27 R'extRext Vo1– Vo1+ R Vo2– Vo2– Vo2+ Vo2+ 4 + Uo1 12 V 15 V 24 V 06005 R'extRext Vo1– Vo1+ R Vo2– Vo2– Vo2+ Vo2+ Uo2 0 V –12/–15/–24 V +12/+15/+24 V Uo1 06006 R'extRext Vo1– Vo1+ R Vo2– Vo2– Vo2+ Vo2+ Uo1 +24/+30/+48 V +12/+15/+24 V 0 V Uo2 112 06007 R'extRext Vo1– Vo1+ R Vo2– Vo2– Vo2+ Vo2+ 4 + Uo1 24 V 30 V 48 V 06004 R'extRext Vo1– Vo1+ R Vo2– Vo2– Vo2+ Vo2+ 4 + Uo2 12 V 15 V
24 V –
+12 V 15 V 24 V U o1 1 06008 R-Function for different output configurations Fig. 21a LS 5000 with H15 connector. R-input for output voltage control. Wiring for output voltage 24 V or 30 V or 48 V with main and second output connected in series. Fig. 21b LS 5000 with H15 connector. R-input for output voltage control. Wiring for output voltage 12 V or 15 V or 24 V with main and second output connected in parallel. Fig. 21c LS 5000 with H15 connector. R-input for output voltage control. Wiring of main and second output for two sym- metrical output voltages Uo1 and Uo2: ±12 V or ±15 V or ±24 V. Fig. 21d LS 5000 with H15 connector. R-input for output voltage control. Wiring of main and second output for two output voltages Uo1 and Uo2: +12 V and +24 V or +15 V and +30 V or +24 V and +48 V. Fig. 21e LS 5000 with H15 connector. R-input for output voltage control. Wiring of main and second output for two output voltages Uo1 and Uo2: 12 V/12 V or 15 V/15 V or 24 V/24 V, the outputs are galvanically isolated. Remarks: Double output units fitted with H15 connectors have the output pins of the second output, pins 4/6 and 8/10, inter- nally paralleled. It is recommended that pins 4/6 and 8/10 be directly paral- leled at the female connector as well to reduce the voltage drop across the connector. Please note: Uo2 varies depending upon its own load and the load on output 1.
1 A ceramic multilayer capacitor connected across the load re-
duces ripple and spikes.
2 Shortest possible wiring for series connection at the female con-
Cassette Style 100 Watt AC-DC Converters S Series PFC Edition 01/01.2001 14/27 Display Status of LEDs Ui max Ui ovUi minUi uv Ui Ui abs OK i Io nom IoL Io OK Io L TC i TC max TPTC threshold Ui inh i Uinh threshold Io L LED off LED on LED Status undefined 06002 Fig. 22 LEDs "OK", "i" and "Io L"status versus input voltage Conditions: Io £ Io nom, TC £ TC max, Uinh £ 0.8 V Ui uv = undervoltage lock-out, Ui ov = overvoltage lock-out LEDs "OK" and "Io L"status versus output current Conditions: Ui min...Ui max, TC £ TC max, Uinh £ 0.8 V LED "i"versus case temperature Conditions: Ui min...Ui max, Io £ Io nom, Uinh £ 0.8 V LED "i"versus Uinh Conditions: Ui min...Ui max, Io £ Io nom, TC £ TC max Test Sockets (Main output only ) Test sockets for measuring the output voltage Uo1 are lo- cated at the front of the module. The positive test socket is protected by a series resistor (see: Functional Description, block diagrams). The voltage measured at the test sockets is approximately 30 mV lower than the value measured at the output terminals. In case of double output units externally connected in se- ries for Uo = 24 V, 30 V or 48 V the monitored output volt- age is 12 V, 15 V or 24 V respectively. Battery Charging/Temperature Sensor The LS are intended for lead acid battery charger applica- tions. For an optimum battery charging and life expectancy of the battery an external temperature sensor may be con- nected to the R-input. The sensor is mounted as close as possible to the battery pole and adjusts the output voltage of the LS unit according to the temperature of the battery (which is related to the load of the battery and the ambient temperature). Depending on the cell voltage and the temperature coeffi- cient of the battery, different sensor types are available. For more information please ask Power-One. Fig. 17 Dependance of output voltage vs. temperature for defined temperature coefficient. 2.10 2.15 2.20 2.25 2.30 2.35 2.40 Cell voltage [V] 0 5 10 15 20 25 30 35 40 45 50 [°C] 06123 Uo max Uz = 2.27 V, –3.5 mV/K Uz = 2.23 V, –3.5 mV/K Uo nom
Cassette Style 100 Watt AC-DC Converters S Series PFC Edition 01/01.2001 15/27 Electromagnetic Compatibility (EMC) A metal oxide VDR together with an input fuse and an input filter form an effective protection against high input tran- sient voltages which typically occur in most installations. The S series has been successfully tested to the following specifications: Electromagnetic Immunity Table 8: Immunity type tests Phenomenon Standard 1 Level Coupling Value Waveform Source Test In Per- mode 2 applied imped. procedure oper. form. 3 Voltage surge IEC 60571-1 i/c, +i/ –i 800 V p 100 µs 100 Ω 1 pos. and 1 neg. yes 4
1500 Vp 50 µs voltage surge per
3000 Vp 5 µs
4000 Vp 1 µs
7000 Vp 100 ns
Supply related RIA 12 B +i/ –i1 . 5 • Ubatt 1 s 0.2 Ω 1 positive yes 4 surge surge Direct transient C +i/c, –i/c 960 V p 10/100 µs5 Ω 5 pos. and 5 neg. yes 4 D 1800 V p 5/50 µs impulses E 3600 V p 0.5/5 µs 100 Ω F 4800 V p 0.1/1 µs G 8400 V p 0.05/0.1 µs Indirect coupled H –o/c, +o/c 1800 V p 5/50 µs transient J 3600 V p 0.5/5 µs K 4800 V p 0.1/1 µs L 8400 V p 0.05/0.1 µs Electrostatic IEC/EN 4 contact discharge 8000 V p 1/50 ns 330 Ω 10 positive and yes A discharge 61000-4-2 air discharge 15000 V p 10 negative (to case) discharges Electromagnetic IEC/EN 3 antenna 10 V/m AM 80% n.a. 80 …1000 MHz yes A field 61000-4-3 1 kHz Electromagnetic ENV 50204 50% duty cycle, 900 ±5 MHz yes A field, 200 Hz repetition pulse modulated frequency Electrical fast IEC/EN 4 capacitive, o/c 2000 V p bursts of 5/50 ns 50 Ω 1 min positive yes A transient/burst 61000-4-4 i/c, +i/ –i 4000 V p 2.5/5 kHz over 1 min negative A direct 15 ms; burst transients per period: 300 ms coupling mode Surge IEC/EN 3 i/c 2000 V p 1.2/50 µs 12 Ω 5 pos. and 5 neg. yes A 61000-4-5 4+ i / –i2 Ω surges per i/c, +i/–i 2500 V p 10/700 µs 40 Ω Conducted IEC/EN 3 i, o, signal wires 10 V rms AM 80% 150 Ω 0.15...80 MHz yes A disturbances 61000-4-6 ( 140 dBµV) 1 kHz 1 Related and previous standards are referenced in: Technical Information: Standards. 2 i = input, o = output, c = case. 3 A = Normal operation, no deviation from specifications, B = Normal operation, temporary deviation from specs possible. 4 Test in progress, please consult factory. Note: Previous standards are referenced in: Technical In- formation: Standards
Cassette Style 100 Watt AC-DC Converters S Series PFC Edition 01/01.2001 16/27 0.01 0.05 0.1 0.5 [dBµV] MHz 0.02 07063 A B Electromagnetic Emission Fig. 23 Typical disturbance voltage (quasi-peak) at the input accord- ing to CISPR 11/22 and EN 55011/22, measured at Ui nom and Io nom. 100 200 500 1000 [dBµV/m] [MHz] A B 07038 Fig. 24 Typical radiated electromagnetic field strength (quasi- peak) according to CISPR 11/22 and EN 55011/22, nor- malized to a distance of 10 m, measured at Ui nom and Io nom.
Cassette Style 100 Watt AC-DC Converters S Series PFC Edition 01/01.2001 17/27 Table 11: MTBF Values at Specified Type Ground Benign Ground Fixed Ground Mobile Unit Case Temperature 40°C4 0 °C7 0 °C5 0 °C MTBF 1 LS 4000/5000 514'000 88'000 38'000 35'000 h 1 Calcualted in accordance with MIL-HDBK217F. Temperature Standard -7 Option -9 Characteristics Conditions min max min max Unit TA Ambient temperature Ui min...Ui max –25 71 –40 71 °C TC Case temperature Io = 0...Io nom –25 95 –40 95 TS Storage temperature Not operational –40 100 –55 100 Immunity to Environmental Conditions Table 9: Environment specifications Test method Standard Test conditions Status Ca Damp heat IEC/DIN IEC 60068-2-3 Temperature: 40 ±2 °C Unit not steady state MIL-STD-810D section 507.2 Relative humidity: 93 +2/-3 % operating Duration: 56 days Ea Shock IEC/EN/DIN EN 60068-2-27 Acceleration amplitude: 100 g n = 981 m/s2 Unit (half-sinusoidal) MIL-STD-810D section 516.3 Bump duration: 6 ms operating Number of bumps: 18 (3 each direction) Eb Bump IEC/EN/DIN EN 60068-2-29 Acceleration amplitude: 40 g n = 392 m/s2 Unit (half-sinusoidal) MIL-STD-810D section 516.3 Bump duration: 6 ms operating Number of bumps: 6000 (1000 each direction) Fc Vibration IEC/EN/DIN EN 60068-2-6 Acceleration amplitude: 0.35 mm (10...60 Hz) Unit (sinusoidal) 5 g n = 49 m/s2 (60...2000 Hz) operating Frequency (1 Oct/min): 10...2000 Hz Test duration: 7.5 h (2.5 h each axis) Fn Vibration IEC 60068-2-64 Acceleration spectral density: 0.05 g n2/Hz Unit broad band DIN 40046 part 23 Frequency band: 5...500 Hz operating random MIL-STD-810D section 514.3 Acceleration magnitude: 4.97 g n rms (digital dontrol) Test duration: 3 h (1 h each axis) Kb Salt mist, cyclic IEC/EN/DIN IEC 60068-2-52 Concentration: 5% (30 °C) Unit not (sodium chloride Duration: 2 h per cycle operating NaCl solution) Storage: 40 °C, 93% rel. humidity Storage duration: 22 h per cycle Number of cycles: 3
Cassette Style 100 Watt AC-DC Converters S Series PFC Edition 01/01.2001 18/27 111 (3U) 168.5 ±0.5 Measuring point of case temperature TC 4.5 19.7 9.5 29.951.5 30.3 20.3 12.1 10.3 7.0 3.27
7 TE 5 TE
Option P (Uo) Option D (Uti) LED OK (green) LED i (red) LED IoL (red) Option D (Uto) 25.9 Front plate Main face Back plate 171.93 (DIN 41494) 11.8 = Ø 3.5 = Ø 4.1 (+/–) 152 100 5 5 81528 09004 Gravitational axis Fig. 26 Aluminium case S02 with option B1 (cooling plate), black finish and self cooling. Total weight: Approx. 1.15 kg Mechanical Data Dimensions in mm. Tolerances ±0.3 mm unless otherwise indicated. Fig. 25 Aluminium case S02 with heatsink, black finish and self cooling, weight: Approx. 1.25 kg Note: – d ≥15 mm, recommended minimum distance to next part to ensure proper air circulation at full output power. – free air locations: the module should be moun- ted with fins in vertical position to achieve a maximum air flow through the heat sink. 111 (3U) 17.3 133.4 168 ±0.5 101 547.2 1585 M 4 Measuring point of case temperature TC 171.93 (DIN 41494) 3.27
7 TE 4 TE
Note: Long case with option B2, elon- gated by 60 mm for 220 mm rack depth, is available on request. (No LEDs, no test jacks.)
Cassette Style 100 Watt AC-DC Converters S Series PFC Edition 01/01.2001 19/27 Safety and Installation Instructions Connector Pin Allocation The connector pin allocation table defines the electrical potentials and the physical pin positions on the H15 con- nector. Pin no. 24, the protective earth pin present on all LS AC-DC converters is leading, ensuring that it makes con- tact with the female connector first. 432 Type H15 10002 Table 12: H15 Connector pin allocation Pin Connector type H 15 No. LS 4000 LS 5000
4 Vo1+
6 Vo1+ Vo2+
8V o 1 – Output 1 Vo2– Output 2
10 Vo1 – Vo2–
12 S+ Sense Vo1+ Output 1
14 S – Sense Vo1 – Output 1
1 Control of Uo1 R 1 Control of Uo1
20 D Save data D Save data
22 T Current sharing T Current sharing
24 2 Protective earth Protective earth
26 N ∼
28 N ∼ N∼
30 P ∼
32 P ∼ P∼
1 Feature R excludes option P and vice versa
2 Leading pin (pregrounding)
3 Option D excludes option V and vice versa
The S series AC-DC converters are components, intended exclusively for inclusion within other equipment by an in- dustrial assembly operation or by professional installers. In- stallation must strictly follow the national safety regulations in compliance with the enclosure, mounting, creepage, clearance, casualty, markings and segregation require- ments of the end-use application. Connection to the system shall be made via the female con- nector H15 (see: Accessories). Other installation methods may not meet the safety requirements. The AC-DC converters are provided with pin no. 24 ( ), which is reliably connected with their case. For safety rea- sons it is essential to connect this pin with the protective earth of the supply system. An input fuse is built-in in the connection from pins no. 30 and 32 (P∼) of the unit. Since this fuse is designed to pro- tect the unit in case of an overcurrent and does not neces- sarily cover all customer needs, an external fuse suitable for the application and in compliance with the local require- ments might be necessary in the wiring to one or both input potentials, pins nos. 26 and 28 and/or nos. 30 and 32. Important: Whenever the inhibit function is not in use, pin no. 18 (i) should be connected to pin no. 14 (S–/Vo1–) to enable the output(s). Do not open the modules, or guarantee will be invali- dated. Due to high current values, all LS units provide two inter- nally parallel connected contacts for certain paths (pins 4/6, 8/10, 26/28 and 30/32, respectively). It is recommended to connect load and supply to both female connector pins of each path in order to keep the voltage drop across the con- nector pins to an absolute minimum and to not overstress the connector contacts if currents are higher than approx. 8 A. The connector contacts are rated 8 A over the whole temperature range. Make sure that there is sufficient air flow available for con- vection cooling. This should be verified by measuring the case temperature when the unit is installed and operated in the end-use application. The maximum specified case tem- perature TC max shall not be exceeded. See also: Thermal Considerations. Check for hazardous voltages before altering any connec- tions. Ensure that a unit failure (e.g. by an internal short-circuit) does not result in a hazardous condition. See also: Safety of operator accessible output circuit. Cleaning Agents In order to avoid possible damage, any penetration of cleaning fluids is to be prevented, since the power supplies are not hermetically sealed. Fig. 27 View of module’s male H15 connector Protection Degree Condition: Female connector fitted to the unit. IP 30: All units except those with option P , and except those with option D or V with potentiometer. IP 20: All units fitted with option P , or with option D or V with potentiometer.
Cassette Style 100 Watt AC-DC Converters S Series PFC Edition 01/01.2001 20/27 Table 13: Isolation Characteristic Input to Input to Output to Output to Unit case output case output Electric Required according to 1.5 3.0 1 –– kVrms strength IEC/EN 60950 2.1 4.2 1 –– kV DCtest voltage Actual factory test 1 s 2.8 5.6 1 1.4 0.14 AC test voltage equivalent 2.0 4.0 1 1.0 0.1 kV rms to actual factory test Insulation resistance at 500 V DC >300 >300 >300 >100 2 MΩ 1 In accordance with IEC/EN 60950 only subassemblies are tested in factory with this voltage. 2 Tested at 100 V DC. For creepage distances and clearances refer to: Technical Information: Safety. Leakage Currents in AC-DC operation Leakage currents flow due to internal leakage capacitance and RFI suppression Y-capacitors. The current values are proportional to the mains voltage and nearly proportional to the mains frequency and are specified at an input voltage of
254 V (50 Hz) where phase, neutral and protective earth
are correctly connected as required for class I equipment. V MI 500 Ω 1500 Ω 10 kΩ 220 nF 22 nF 10061 Under test conditions the leakage current flows through a measuring instrument (MI) as described in fig.: Measuring instrument for earth leakage current tests, which takes into account impedance and sensitivity of a person touching unearthed accessible parts. The current value is calculated by dividing the measured voltage by 500 Ω. If inputs of S- units are connected in parallel, their individual leakage cur- rents are added. Fig. 28 Measuring instrument (MI) for earth leaking current tests according to IEC/EN 60950. Vo+ Vo– N P 10062 N P MI for earth leakage current Fig. 29 Test set-up Standards and Approvals All AC-DC converters correspond to class I equipment. They are UL recognized according to UL 1950, UL recog- nized for Canada to CAN/CSA C22.2 No. 950-95 and LGA approved to IEC/EN 60950 standards. The units have been evaluated for:
- Building in
- Basic insulation between input and case, based on 250 V AC and 400 V DC
- Double or reinforced insulation between input and output, based on 250 V AC and 400 V DC
- Basic insulation between output and case based on
200 V AC and DC
- Operational insulation between output and output
- Connecting the input to a primary or secondary circuit which is subject to a maximum transient rating of 2500 V (overvoltage category III based on a 110 V primary cir- cuit, overvoltage category II based on a 230 V primary circuit).
- The use in a pollution degree 2 environment
- The UL 1950 recognition limits the minimum input voltage to Ui = Ui min + 5 V AC = 90 V AC if the case temperature exceeds 90°C. The AC-DC converters are subject to manufacturing sur- veillance in accordance with the above mentioned UL, CSA, EN and with ISO 9001 standards. Isolation The electric strength test is performed as factory test in ac- cordance with IEC/EN 60950 and UL 1950 and should not be repeated in the field. Power-One will not honour any guarantee claims resulting from electric strength field tests. Important: Testing by applying AC voltages will result in high and dangerous leakage currents flowing through the Y-capacitors (see fig.: Block diagram).
Cassette Style 100 Watt AC-DC Converters S Series PFC Edition 01/01.2001 21/27 P Potentiometer The potentiometer provides an output voltage adjustment range of +10/–60% of Uo nom and is accessible through a hole in the front cover. This feature enables compensation for voltage drops across the connector and wiring. Option P is not recommended if units are connected in parallel. Option P excludes the R-function. With double output units both outputs are affected by the potentiometer setting (dou- bling the voltage setting if the outputs are in series). If the output voltages are increased above Uo nom via R-in- put control, option P setting, remote sensing or option T, the output current(s) should be reduced accordingly so that Po nom is not exceeded. -9 Extended Temperature Range Option –9 extends the operational ambient temperature supplies provide full nominal output power with convection cooling. Option -9 excludes inrush current limitation by NTC. Description of Options Table 16: Survey of options Option Function of option Characteristic –9 Extended operational ambient temperature range TA = –40...71°C E Electronic inrush current limitation circuitry Active inrush current limitation P 1 Potentiometer for fine adjustment of output voltage Adjustment range +10/-60% of Uo nom, excludes R input D 2 Input and/or output undervoltage monitoring circuitry Safe data signal output (D0...DD) V 2 3 Input and/or output undervoltage monitoring circuitry ACFAIL signal according to VME specifications (V0, V2, V3) T Current sharing Interconnect T-pins if paralleling outputs (5 units max.) B1, B2 Cooling plate Replaces standard heat sink, allowing direct chassis-mounting
1 Function R excludes option P and vice versa
2 Option D excludes option V and vice versa
3 Only available if main output voltage Uo1 = 5.1 V Table 14: Leakage currents Characteristic Class I Unit LS 4000...LS 5000 Maximum earth Permissible according to IEC/EN 60950 3.5 mA leakage current Specified value at 254 V, 50 Hz 0.82 Safety of operator accessible output circuit If the output circuit of an AC-DC converter is operator ac- cessible, it shall be an SELV circuit according to the IEC/EN 60950 related safety standards. The following table shows a possible installation configura- tion, compliance with which causes the output circuit of an S series AC-DC converter to be an SELV circuit according to IEC/EN 60950 up to a configured output voltage (sum of nominal voltages if in series or +/– configuration) of 36 V. However, it is the sole responsibility of the installer to as- sure the compliance with the relevant and applicable safety regulations. More information is given in: Technical Infor- mation: Safety. Table 15: Safety concept leading to an SELV output circuit Conditions AC-DC converter Installation Result Nominal voltage Grade of insulation Measures to achieve the resulting Safety status of the AC-DC between input and output safety status of the output circuit converter output circuit provided by the AC-DC converter Mains Double or reinforced Earthed case 1 and installation SELV circuit ≤250 V AC according to the applicable standards 1 The earth connection has to be provided by the installer according to the relevant safety standards, e.g. IEC/EN 60950. AC-DC con- verter Mains SELV Earth connection 10021 Fuse Fuse Fig. 30 Schematic safety concept. Use fuses and earth connec- tion as per Installation Instructions and table Safety con- cept leading to an SELV output circuit.
Cassette Style 100 Watt AC-DC Converters S Series PFC Edition 01/01.2001 22/27 Fig. 34 Paralleling of single output units using option T with the sense lines connected at the load Load max. 5 units in parallel connection + – Power bus Module Vo2– Vo2+ Vo1– Vo1+ T Module Vo2– Vo2+ Vo1– Vo1+ T 11037 Load LS 4000 Vo+ Vo– N P T LS 4000 N P Vo+ Vo– T max. 5 units connected in parallel 11011
1 Leads should have equal length and cross sections and should
run in the same cable loom.
2 Diodes recommended in redundant operation only
3 DC common point
Fig. 35 Paralleling of double output units using option T with Power bus. E Inrush Current Limitation The converters may be supplemented by an electronic cir- cuit (option E, replacing the standard built-in NTC) to achieve an enhanced inrush current limiting function. Table 17: Inrush current characteristics with option E Characteristics LS Unit Ui = 230 V AC typ max Iinr p Peak inrush current – 25.3 A tinr Inrush current duration 35 50 ms Ii [A] –10 0 20 40 60 80 t [ms] tinr Capacitor Ci fully charged Normal operation (FET fully conducting) 10 50 70 30 11002 Fig. 32 Inrush current with option E, Ui = 230 V AC, Po = Po nom Precaution: Subsequent switch-on cycles at start-up are limited to max. 10 cycles during the first 20 seconds (cold unit) and at continuing on/off ( TC =9 5°C) max. 1 cycle every 8s e c . Vo+ Vo– Vo+ Vo– Load Vo+ Vo– 11003 Input Filter Control Converter FET CiRIRS Rectifier PFC - Control 11001 Fig. 31 Option E block diagram T Current Sharing This option ensures that the output currents are approxi- mately shared between all paralleled modules and in- creases system reliability. To use this facility, simply inter- connect the T pins of all modules and make sure, that pin 14, the S – pin (S 4000) or the Vo1 – pins (S 5000) are also connected together. The load leads should have equal length and cross section to ensure equal voltage drops. Not more than 5 units should be connected in parallel. If output voltage adjustment is requested we strongly recommend to use the R-input instead of option P , as with option P the re- quired setting accuracy is dif ficult to achieve. The output voltages must be individually set prior to paralleling to within a tolerance of 1...2% or the R pins should be con- nected together. Fig. 33 An example of poor wiring for connection in parallel
Cassette Style 100 Watt AC-DC Converters S Series PFC Edition 01/01.2001 23/27 Table 19: D-output logic signals Version of D Ui < Ut resp. Uo < Ut Ui > Ut + Uh resp. Uo > Ut Configuration D1, D2, D3, D4, D0 low high JFET D5, D6, D7, D8, D9, DD high low NPN D Undervoltage Monitor The input and/or output undervoltage monitoring circuit op- erates independently of the built-in input undervoltage lock- out circuit. A logic "low" (JFET output) or "high" signal (NPN output) is generated at pin 20 as soon as one of the moni- tored voltages drops below the preselected threshold level Ut. The return for this signal is Vo1–. The D output recovers when the monitored voltage(s) exceed(s) Ut + U h. The Table 18: Undervoltage monitoring functions Output type Monitoring Minimum adjustment range Typical hysteresis Uho [% of Ut] JFET NPN U i Uo1 of threshold level U t for U t min...U t max Uti Uto Uho D2 D6 yes no 355V DC 4 --
1 Threshold level adjustable by potentiometer
2 Fixed value. Tracking if Uo1 adjusted via R-input, option P or sense lines. 3 The threshold level permanently adjusted according to customer specification ±2% at 25 °C. Any value within the specified range is basically possible but causes a special type designation in addition to the standard option designations (D0/D9)! 4 Option D monitors the boost regulator output voltage. The trigger level is adjusted in the factory to 355 V DC. threshold level Uti is adjusted in the factory. The threshold level Uto is either adjusted by a potentiometer, accessible through a hole in the front cover, or factory adjusted to a fixed value specified by the customer. Option D exists in various versions D0...DD as shown in the following table. Vo1+ Vo1– D UD ID Rp Input 11007 Vo1+ Vo1– D UD ID Rp Input 11006 Fig. 36 Option D0...D4: JFET output, ID ≤ 2.5 mA NPN output (D5...DD): Connector pin D is internally connected via the collector- emitter path of a NPN transistor to the negative potential of output 1. UD < 0.4 V (logic low) corresponds to a monitored voltage level ( Ui and/or Uo1) > U t + U h. The current ID through the open collector should not exceed 20 mA. The NPN output is not protected against external overvoltages. UD should not exceed 40 V. Ui, Uo1 status D output, UD Ui or Uo1 < Ut high, H, ID ≤ 25 µA at UD = 40 V Ui and Uo1 > Ut + Uh low, L, UD ≤ 0.4 V at ID = 20 mA JFET output (D0…D4): Connector pin D is internally connected via the drain- source path of a JFET (self-conducting type) to the nega- tive potential of output 1. UD ≤ 0.4 V (logic low) corresponds to a monitored voltage level ( Ui and/or Uo1) <Ut. The cur- rent ID through the JFET should not exceed 2.5 mA. The JFET is protected by a 0.5 W Zener diode of 8.2 V against external overvoltages. Ui, Uo1 status D output, UD Ui or Uo1 < Ut low, L, UD ≤ 0.4 V at ID = 2.5 mA Ui and Uo1 > Ut + Uh high, H, ID ≤ 25 µA at UD = 5.25 V Fig. 37 Option D5...DD: NPN output, Uo1 ≤ 40 V, ID ≤ 20 mA
Cassette Style 100 Watt AC-DC Converters S Series PFC Edition 01/01.2001 24/27 0.95 Uci [V DC] t t t tlow min4 tlow min4 thigh min th1 358 355 Input voltage failure Switch-on cycle Input voltage sag Switch-on cycle and subsequent input voltage failure UD high UD low UD JFET NPN t Uo1 Uo1 nom UD high UD low UD tlow min4th1 UD high UD low UD JFET NPN Uo1 UD high UD low UD tlow min4 Uto Output voltage failure ID high ID low ID t ID high ID low ID t t t t 33 33 Uo1 nom Uto +Uho Input voltage monitoring Output voltage monitoring 11044 1 Hold-up time see section Electrical Input Data. 2 With output voltage monitoring, hold-up time th = 0.
3 The signal will remain high if the D output is connected to
an external source. 4 tlow min = 100...170 ms, typically 130 ms. Fig. 38 Relationship between Uci, Uo1, UD, Uo1/Uo nom versus time D-signal with respect to input and output voltage versus time:
Cassette Style 100 Watt AC-DC Converters S Series PFC Edition 01/01.2001 25/27 V ACFAIL Signal (VME) Available for units with Uo1 = 5.1V This option de fines an undervoltage monitoring circuit for the input or input and main output voltage equivalent to op- tion D and generates the ACFAIL signal (V signal) which conforms to the VME standard. The low state level of the ACFAIL signal is speci fied at a sink current of IV ≤ 48 mA to UV ≤ 0.6 V (open-collector out- put of a NPN transistor). The pull-up resistor feeding the open-collector output should be placed on the VME back plane. After the ACFAIL signal has gone low, the VME standard requires a hold-up time th of at least 4 ms before the 5.1 V output drops to 4.875 V when the output is fully loaded. This hold-up time th is provided by the internal input capaci- tance. See also fig.: Hold-up Time versus Output Power. Table 20: Undervoltage monitor functions V output Monitoring Minimum adjustment (VME compatible) Ui Uo1 range of threshold level Uti Uto V2 yes no 355V DC 1 – 1 Option D monitors the boost regulator output voltage. The trig- ger level is adjusted in the factory to 355 V DC. 2 Fixed value between 95% and 98.5% of Uo1. Vo1+ Vo1– V UV IV Rp Input 11009 V output (V2, V3): Connector pin V is internally connected to the open collec- tor of a NPN transistor. The emitter is connected to the negative potential of output 1. UV ≤ 0.6 V (logic low) corre- sponds to a monitored voltage level ( Ui and/or Uo1) <Ut. The current IV through the open collector should not ex- ceed 50 mA. The NPN output is not protected against ex- ternal overvoltages. UV should not exceed 60 V. Ui, Uo1 status V output, UV Ui or Uo1 < Ut low, L, UV ≤ 0.6 V at IV = 50 mA Ui and Uo1 > Ut + Uh high, H, IV ≤ 25 µA at UV = 5.1 V Fig. 39 Output configuration of options V2 and V3 Option V operates independently of the built-in input under- voltage lock-out circuit. A logic "low" signal is generated at pin 20 as soon as one of the monitored voltages drops be- low the preselected threshold level Ut. The return for this signal is Vo1–. The V output recovers when the monitored voltage(s) exceed(s) Ut + Uh. The threshold level Uti is ad- justed in the factory to 355 V DC. The threshold level Uto either is adjusted during manufacture to a determined cus- tomer specified value.
Cassette Style 100 Watt AC-DC Converters S Series PFC Edition 01/01.2001 26/27 5.1 V 4.875 V Uci [V DC] t t 358 355 Input voltage failure Switch-on cycle Input voltage sag Switch-on cycle and subsequent input voltage failure UV high UV low UV t Uo1 UV high UV low UV Ui Uti Output voltage failure UV high UV low UV Uti + Uhi tlow min 2 tlow min 2tlow min 2 3 3 UV high UV low UV t tlow min 2tlow min 2 3 3 th 1 2.0 V th 1 tlow min 2 5.1 V 4.875 V Uo1 2.0 V Input voltage monitoring Output voltage monitoring 11045 t t t t Fig. 40 Relationship between Uci, Uo1, UV, IV and Uo1/Uo nom ver- sus time.
1 VME request: minimum 4 ms
2 tlow min = 40...200 ms, typically 80 ms 3 UV level not defined at Uo1 < 2.0 V
4 The V signal drops simultaneously with the output voltage if the
pull-up resistor RP is connected to Vo1+. The V signal remains high if RP is connected to an external source.
Cassette Style 100 Watt AC-DC Converters S Series PFC Edition 01/01.2001 27/27 Accessories A variety of electrical and mechanical accessories are available including: – Front panels for 19" rack mounting, Schroff and Intermas systems. – Mating H15 connectors with screw, solder, fast-on or press-fit terminals. – Connector retention facilities. – Code key system for connector coding. – Chassis mounting plates for mounting the 19" cassette to a chassis/wall where only frontal access is given. – Universal mounting bracket for DIN-rail or chassis moun- ting. For more detailed information please refer to: Accessory Products. Front panels H15 female connector, Code key system Mounting plate, Connector retention clips Universal mounting bracket for DIN-rail mounting. Chassis mounting bracket S B1 Cooling Plate (see: Mechanical Data) Where a cooling surface is available, we recommend the use of a cooling plate (option B1) instead of the standard heatsink. The mounting system should ensure suf ficient cooling capacity to guarantee that the maximum case tem- perature TC max is not exceeded. The cooling capacity is cal- culated by: Efficiency η see: Type survey. Elongated case for 220 mm rack depth: Option B2.