LS33600 SAFT | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
l High voltage response, stable during most of the lifetime of the application l Wide operating temperature range (-60°C/85°C) l Easy integration in compact system l Low self-discharge rate (less than 1 % after 1 year of storage at + 20°C) Key features l Stainless steel container l Hermetic glass-to-metal sealing l Built-in safety vent l Finish with or without flat positive end l Non-flammable electrolyte l Compliant with IEC 60086-4 safety standard and IEC 60079-11 intrinsic safety standard l Underwriters Laboratories (UL) Component Recognition (File Number MH 12609) l Restricted for transport (Class 9) Main applications l Utility metering l Automatic meter readers l Buoys l Measuring equipment l Industrial applications l Professional electronics l Marine equipment Optional upon request l Low magnetic version July 2010 Cell size references D Primary lithium battery LS 33600
3.6 V Primary lithium-thionyl chloride (Li-SOCl2)
Electrical characteristics
(typical values relative to cells stored for one year or less at + 30°C max.) Nominal capacity 17.0 Ah (at 5 mA + 20°C 2.0 V cut-off. The capacity restored by the cell varies according to current drain, temperature and cut-off) Open circuit voltage (at + 20°C) 3.67 V Nominal voltage (at 0.7 mA + 20°C) 3.6 V Nominal energy 61.2 Wh Pulse capability: Typically up to 400 mA (400 mA/0.1 second pulses, drained every 2 mn at + 20°C from undischarged cells with 10 µA base current, yield voltage readings above 3. 0 V. The readings may vary according to the pulse characteristics, the temperature, and the cell’s previous history. Fitting the cell with a capacitor may be recommended in severe conditions. Consult Saft) Maximum recommended continuous current 250 mA (to maintain cell heating within safe limits. Battery packs may imply lower level of maximum current and may request specific thermal protection. Consult Saft) Storage (recommended) + 30°C (+ 86°F) max (for more severe conditions, consult Saft) Operating temperature range - 60°C/+ 85°C (Operation above ambient T may lead to reduced capacity and (- 76°F/+ 185°F) lower voltage readings at the beginning of pulses. Consult Saft) Physical characteristics Diameter (max) 33.4 mm (1.32 in) Height (max) 60.2 or 61.6 mm (2.37 in or 2.42 in) depending on finish type Typical weight 90 g (3.2 oz) Li metal content approx. 4.5 g Available termination suffix CN, CNR radial tabs CNA (AX) axial leads FL flying leads... etc.
+ 20°C - 20°C - 40°C
15 Ohms/200 mA
30 Ohms/107 mA
515 Ohms/6.9 mA 1000 Ohms/3.5 mA + 55°C + 20°C - 40°C - 20°C 0.1 1 101 100 1000 3.5 3.3 3.1 2.9 2.7 2.5 2.3 2.1 1.9 1.7 0.1 1 10 100 1000 10000 0.1 1 10 100 1000 3.6 3.5 3.4 3.3 3.2 3.1 3.0 2.9 2.8 2.7 2.6 2.5 16.0 14.0 12.0 10.0 8.0 6.0 4.0 2.0 + 20°C - 20°C - 40°C 515 Ohms/6.9 mA 1000 Ohms/3.5 mA + 55°C + 20°C - 40°C - 20°C 0.1 1 101 100 1000 3.5 3.3 3.1 2.9 2.7 2.5 2.3 2.1 1.9 1.7 0.1 1 10 100 1000 10000 0.1 1 10 100 1000 3.6 3.5 3.4 3.3 3.2 3.1 3.0 2.9 2.8 2.7 2.6 2.5 16.0 14.0 12.0 10.0 8.0 6.0 4.0 2.0 + 20°C - 20°C - 40°C 515 Ohms/6.9 mA 1000 Ohms/3.5 mA + 55°C + 20°C - 40°C - 20°C 0.1 1 101 100 1000 3.5 3.3 3.1 2.9 2.7 2.5 2.3 2.1 1.9 1.7 0.1 1 10 100 1000 10000 0.1 1 10 100 1000 3.6 3.5 3.4 3.3 3.2 3.1 3.0 2.9 2.8 2.7 2.6 2.5 16.0 14.0 12.0 10.0 8.0 6.0 4.0 2.0 Storage
- The storage area should be clean, cool (preferably not exceeding + 30°C), dry and ventilated. Warning
- Fire, explosion and burn hazard.
- Do not recharge, short circuit, crush, disassemble, heat above 100°C (212°F), incinerate, or expose contents to water.
- Do not solder directly to the cell (use tabbed cell versions instead). 2.1 ± 0.2 61.0 ± 0.6 0.5 Ø 33.1 ± 0.3 Ø 13.8 ± 0.2 (on flat surface) 0.6 ± 0.2 0.5 59.6 ± 0.6 Ø 18.0 ± 0.2 (on flat surface) Ø 9.3 ± 0.1 (on flat surface) Ø 33.1 ± 0.3 Ø 18.0 ± 0.2 (on flat surface) 2.1 ± 0.2 61.0 ± 0.6 0.5 Ø 33.1 ± 0.3 Ø 13.8 ± 0.2 (on flat surface) 0.6 ± 0.2 0.5 59.6 ± 0.6 Ø 18.0 ± 0.2 (on flat surface) Ø 9.3 ± 0.1 (on flat surface) Ø 33.1 ± 0.3 Ø 18.0 ± 0.2 (on flat surface) Finished version with protruding positive end cap Finished version with flat positive end cap Dimensions in mm. Doc. No 31007-2- 0710 Information in this document is subject to change without notice and becomes contractual only after written confirmation by Saft. For more details on primary lithium technologies please refer to Primary Lithium Batteries Selector Guide Doc N o 31048-2. Published by the Communications Department. Photo credit: Saft Société anonyme au capital de 31 944 000 RCS Bobigny B 383 703 873 Produced by Arthur Associates Limited. Current (mA) Time (hours) Current (mA) Restored Capacity versus Current and Temperature (2.0 V cu t-off) Typical discharge profiles at + 20°C Voltage plateau versus Current and Temperature (at mi d-discharge) Saft Specialty Battery Group 12, rue Sadi Carnot
93170 Bagnolet - France
Tel.: +33 (0)1 49 93 19 18 Fax: +33 (0)1 49 93 19 69 www.saftbatteries.com Cell voltage (V)Cell voltage (V)Capacity (Ah)