Business-Critical Continuity LPX50 Enclosure Installation Notes LPX50 • Cover Enclosure Kit LPX50 will fit the LPX5X and LP X10X-M power supplies. Installation Instructions and Notes 1. Place the insulator over the chassis as shown. 2. Place the power supply over the insulator as shown. 3. Align the 4x power supply to the chassis standoff. 4. Secure 4 pan head screws with washer provided with in kit as shown. 5. Place the cover over the power supply as shown. 6. Align the 4x cover to the U-bracket countersink holes. 7. Secure 4 countersink screws provided with in kit as shown. 9. Base plate has three sets of customer mountings: a. Bottom mounting (4X) M3 inserts. Max. screw penetration 0. 0787 (2mm) b. Side mounting (2X) 4mm clear holes plus 2 keyways. (See keyway detail) c. Side mounting (4X) M3 inserts. Max. screw penetration 0.236 (6mm) 10. Ensure insulator is correctly fitted in base under PCB to maintain safety creepage and clearances. 11. Ensure base is firmly connected to supply earth via the earth stud marked 12. When using this enclosure, ensure that relevant safety standards (e.g. EN60950) are complied with, in respect to creepage and clearance distances, and distances through insulation. 13. All dimensions are in inches (mm) Rev. 02.16.09_159 LPX50 Enclosure 1 of 2 1.457 37,0[ ]1.260 32,0[ ] 2.945 74,8[ ] 4.685 1 19,0[ ] 1.693 43,0[ ] (2X) 0.591 15,0[ ] 25,5[ ] 1.724 43,8[ ] 2.205 56,0[ ]2.165 55,0[ ] (2X) 0.390 9,9[ ] (2X) 2.283 58,0[ ] (2X) 0.577 14,7[ ] (2X) 1.201 30,5[ ] (2X) 0.197 5,0[ ] 1.654 42,0[ ] MATERIALS
1 Base
1 Cover
4 M3X6mm Pan head screws with spring washer
4 M3X6mm Countersunk screws
1 M4 nut
1 M4 star washer
1 M4 spring washer
1 Plastic insulator sheet
- All dimensions are in inches(mm) 2. Overall dimensions 3. Base plate has three sets of customer mountings: a. Bottom mounting(4X)M3 inserts. Max. screw penetration 0.0787(2mm) b. Bottom mounting(2X)4mm clear holes plus 2 keyways.(see keyway detail) c. Side mountings(4X)M3 inserts. Max. screw penetration 0.236(6mm) 4. Ensure insulator is correctly fitted in base under PCBto maintain safety creepage and clearances. 6. When using this enclosure, ensure that relevant safety standards (e.g.,EN60950)are complied with, in respect to creepage and clearance distances, and distances through insulation. (2X)M3 INSERT (2X)M3 INSERT A A A A (4X)M3 INSERT MARKED"A" SEE KEYWAY DETAILS INPUT TERMINALS (4X)STANDOFF GROUND STUD INSULATOR OUTPUT TERMINALS (2X) KEYWAY DETAIL 0.25(6.4) Materials
4 M3x6mm Pan head
4 M3x6mm countersunk
Business-Critical Continuity 313 process yellow 3405 1797 1375 116 2607 652 242 2985 375 240 Mechanical Drawing Americas
5810 Van Allen Way
Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Asia (HK) 14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 For global contact, visit: www.PowerConversion.com techsupport.embeddedpower @emerson.com While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2008 Emerson Electric Co. EmersonNetworkPower.com Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Rev. 02.16.09_159 LPX50 Enclosure 2 of 2 1.457 37,0[ ]1.260 32,0[ ] 2.945 74,8[ ] 4.685 1 19,0[ ] 1.693 43,0[ ] (2X) 0.591 15,0[ ] 25,5[ ] 1.724 43,8[ ] 2.205 56,0[ ]2.165 55,0[ ] (2X) 0.390 9,9[ ] (2X) 2.283 58,0[ ] (2X) 0.577 14,7[ ] (2X) 1.201 30,5[ ] (2X) 0.197 5,0[ ] 1.654 42,0[ ] MATERIALS
- All dimensions are in inches(mm) 2. Overall dimensions 3. Base plate has three sets of customer mountings: a. Bottom mounting(4X)M3 inserts. Max. screw penetration 0.0787(2mm) b. Bottom mounting(2X)4mm clear holes plus 2 keyways.(see keyway detail) c. Side mountings(4X)M3 inserts. Max. screw penetration 0.236(6mm) 4. Ensure insulator is correctly fitted in base under PCBto maintain safety creepage and clearances. 6. When using this enclosure, ensure that relevant safety standards (e.g.,EN60950)are complied with, in respect to creepage and clearance distances, and distances through insulation. (2X)M3 INSERT (2X)M3 INSERT A A A A (4X)M3 INSERT MARKED"A" SEE KEYWAY DETAILS INPUT TERMINALS (4X)STANDOFF GROUND STUD INSULATOR OUTPUT TERMINALS (2X) KEYWAY DETAIL 0.25(6.4)