www.pairuigroup.com Page: 1 / 8 Date: 04/29/2014 Constant current LED Drivers For outdoor use LPU-120C Series, 120Watt FEATURES: /checkbld/checkbld /checkbld/checkbldConstant current output /checkbld/checkbld /checkbld/checkbldInput voltage range 100-277Vac /checkbld/checkbld /checkbld/checkbldShort circuit, over current, over voltage and over temperature protections /checkbld/checkbld /checkbld/checkbldDesigned to worldwide safety standards for lighting /checkbld/checkbld /checkbld/checkbldActive power factor correction /checkbld/checkbld /checkbld/checkbldIP67 for outdoor use /checkbld/checkbld /checkbld/checkbldMultiple dimming /checkbld/checkbld /checkbld/checkbld5 year warranty Model Input voltage (Vac) Output current (mA) Output voltage (Vdc) Output power (W) Min. Max. LPU120-C350 100-277 350 172 343 120 LPU120-C530 530 113 226 119.8 LPU120-C700 700 86 171 119.7 LPU120-C1050 1050 57 114 119.7 LPU120-C1400 1400 43 86 120.4 LPU120-C1750 1750 35 69 120.75 LPU120-C2100 2100 29 57 119.7 LPU120-C2800 2800 22 43 120.4 LPU120-C3500 3500 17 34 119 LPU120-C5000 5000 12 24 120 Note: You may request for the models with different dimming functions, plus “D/P/T/A” in the suffix: e.g. LPU120-C350D. Blank —— —— Without Dimming D—— —— 0-10V or Resistor Dimming P—— —— PWM Dimming T—— —— Timer Dimming A—— —— 3 in 1 Programmable Dimming ELECTRICAL Input Parameters Symbols Test Conditions / Comment Min. Typ. Max. Units Input Voltage Vin --- 100 -- 277 Vac Input Frequency Fline --- 47 -- 63 Hz Input Current Iin Full Load, Vin =100Vac Full Load, Vin =220Vac Full Load, Vin =277Vac -- -- 1.2 0.56 0.45 A Inrush Current Iinrush Cold Start, Vin =230Vac -- -- 50 A

www.pairuigroup.com Page: 2 / 8 Date: 04/29/2014 Constant current LED Drivers For outdoor use LPU-120C Series, 120Watt ELECTRICAL Input Parameters Symbols Test Conditions / Comment Min. Typ. Max. Units Power Factor PF 70% ~100% Load, Vin =100Vac 70% ~100% Load, Vin =220Vac 70% ~100% Load, Vin =277Vac 0.98 0.95 0.90 -- -- PF Total Harmonic Distortion THD 70% ~100% Load, Vin =100Vac 70% ~100% Load, Vin =220Vac 70% ~100% Load, Vin =277Vac -- -- Efficiency η Full voltage, full load 88 91 93 % Leakage Current Ileakage Vin =277Vac/ 60Hz -- -- 0.5 mA Output Output Current Iout LPU120-C350 332 350 368 mA LPU120-C530 503 530 557 mA LPU120-C700 665 700 735 mA LPU120-C1050 997 1050 1102 mA LPU120-C1400 1330 1400 1470 mA LPU120-C1750 1663 1750 1837 mA LPU120-C2100 1995 2100 2205 mA LPU120-C2800 2660 2800 2940 mA LPU120-C3500 3325 3500 3675 mA LPU120-C5000 4750 5000 5250 mA Output Voltage Vout LPU120-C350 172 -- 343 V LPU120-C530 113 -- 226 V LPU120-C700 86 -- 171 V LPU120-C1050 57 -- 114 V LPU120-C1400 43 -- 86 V LPU120-C1750 35 -- 69 V LPU120-C2100 29 -- 57 V LPU120-C2800 22 -- 43 V LPU120-C3500 17 -- 34 V LPU120-C5000 12 -- 24 V Line Regulation Iout-line Vin from 100Vac to 277Vac -- -- 1 % Load Regulation Iout-load Vout from min. to max. -- -- 1 % Turn-On Delay Time Ton_delay Cold Start, Power ON -- 1 1.5 S

www.pairuigroup.com Page: 3 / 8 Date: 04/29/2014 Constant current LED Drivers For outdoor use LPU-120C Series, 120Watt ELECTRICAL Output Parameters Symbols Test Conditions / Comment Min. Typ. Max. Units Ripple Current Iout-ripple Full Load, (pk-to-pk)/Average -- -- 20 % Output Current Overshoot Iovershoot Turning Power ON -- -- 10 % +12V Auxiliary Output (Optional) 12V Output Voltage VAUX A +12V auxiliary output provides power for active LED cooler or other active equipment. 11 12 13 V 12V Output Current IAUX 0 -- 100 mA Auxiliary Power PAUX -- -- 1.2 W 0-10V or Resistor Dimming The 0-10V or resistor dimming is a dimming manner that can be u sed to dim the output current via a standard commercial wall dimmer (0-10Vdc or 1-10Vdc) or an external control voltage source (0-10Vdc or 1-10Vdc) or external resistor. /circle6The dimming range is 100% Iout to 5% Iout . When VDIM is 9-10Vdc, the output current maintains 100% Iout, and when VDIM is 1V, the output current is 5% Iout. /circle6When VDIM below 0.7V, the driver will shut down and it will recovery when VDIM goes above 1V. See “0-10V Dimming Curve” for detailed information. Absolute Maximum Voltage on 0-10V pin VDIM --- 2 -- 15 V Source Current on 0-10V Dimming Pin IDIM --- 50 75 100 μA VDIM Voltage for Full Bright VDIM-MAX --- 9 -- -- V Minimum Output Current IOUT-MIN VDIM =1V -- 5% -- % of Iout VDIM Voltage When The Driver Shut Down VDIM-SHUT --- 0.6 0.7 0.8 V VDIM Voltage When the Driver Recovery After Shut Down VDIM -recovery --- 0.9 1 1.1 V External Resistor Value at Full Bright RExternal-MAX See “External Resistor Dimming Curve (D Type)” for details -- 20 -- KΩ

www.pairuigroup.com Page: 4 / 8 Date: 04/29/2014 Constant current LED Drivers For outdoor use LPU-120C Series, 120Watt ELECTRICAL PWM Dimming The PWM dimming is a dimming manner that can be used to dim the output current via the duty cycle of PWM signal. /circle6The dimming range is 100% I out to 5% Iout . When the duty cycle is 100%, the output current reaches 100% Iout , and the output current maintains 5% Iout when the duty cycle below 5%. /circle6When the PWM signal is low the driver will shut down and it will recovery when the duty cycle goes above 5%. See “PWM Dimming Curve” for detailed information. Parameters Symbols Test Conditions / Comment Min. Typ. Max. Units PWM Frequency FPWM --- 0.1 -- 2 KHz High Level Voltage of PWM Signal VPWM-High --- 4 -- 1.2 V Lower Level Voltage of PWM Signal VPWM-Low --- 0 -- 1 V Minimum Output Current IOUT-MIN When duty cycle below 5% -- 5 -- % of Iout Timer Dimming The Timer Dimming is designed with time controlled dimming f unction, it will dim to 50% of rated output current after operating six hours. See “ T Type Dimming Curve” for detailed information. Full Load Operated Time TFULL-LOAD-TTY PE Note1, The dimming time and dimming current can be customized Note2, Timing shut down function can be customized 5.5 6 6.5 Hrs Dim Output Current IOUT-MIN-TTYPE 45 50 55 % of Iout LED Board Temperature Detection(Optional) The LED board temperature detection input can be connected t o a thermistor (NTC) to realize a LED Board Over Temperature Protection and prevent the LED lamp from damage or luminous decay at high temperature. The thermistor should be located on the LED assembly to monit or its temperature. If the temperature exceeds the predetermined LED OTP point, the output current of the drive r is automatically reduced to regulate the temperature of th e LED board at a safe level. See “LED OTP Current Reduction Curve” for detailed information. Thermistor Resistance Value that Start Current Reduction RLEDOTP When the thermistor resistance less than this value the output current start reduce. -- 4 -- KΩ

www.pairuigroup.com Page: 5 / 8 Date: 04/29/2014 Constant current LED Drivers For outdoor use LPU-120C Series, 120Watt ELECTRICAL Protection Parameters Symbols Test Conditions / Comment Min. Typ. Max. Units Over Voltage VOVP --- -- 110% 150% Vout Short Circuit Hiccup mode, it will recover automatically af ter fault conditions remove Over Temperature VOVP If the temperature exceeds OTP point, the output current of the driver is automatically reduced. 90 95 100 Environment Storage Temperature Tstorage Humidity: 5% RH to 95% RH -40 -- +85 ℃ Ambient Operating Temperature Ta Startup at rated voltage -40 -- +70 ℃ Maximum Case Temperature TC Hot-spot on case -- -- +90 ℃ Operating Relative Humidity Ha Non condensing 10 -- 95 % Life Time TLife Full load, case temperature 55 ℃ 50 -- -- kHrs MTBF TMTBF Full load, 220Vac input, 25 ℃ Ambient temperature 200 -- -- kHrs Net Weight WNBT --- -- 790 -- g Dimension(LxWxH) 192 x 70 x 34mm EMC Compliance EN55015 Conducted Emission & Radiated Emission EN61000-3-2 Class C Harmonic Current Emission EN61000-3-3 Voltage fluctuations and flicker FCC Part 15 Class B Conducted and Radiated Emission Measurem ent EN61547 Equipment for general lighting purposes: EMC Immun ity Requirements EN61000-4-2 Electrostatic Discharge (ESD). Air Discharge : 15kV; Contact Discharge: 8kV EN61000-4-3 Radiated Radio-Frequency electromagnetic fi eld EN61000-4-5 Surge Immunity Test: L-N 6KV, L/N-GND 6KV EN61000-4-6 Conducted disturbances induced by Radio-Freq uency fields EN61000-4-8 Power Frequency Magnetic Field Test

www.pairuigroup.com Page: 6 / 8 Date: 04/29/2014 Constant current LED Drivers For outdoor use LPU-120C Series, 120Watt ELECTRICAL EMC Compliance EN61000-4-11 Voltage Dips, short interruptions and Voltag e Variations Note: Unless otherwise specified, all the above parameters are measured at ambient temperature of 25 ℃ and Vin = 100Vac to 277Vac. TYPICAL APPLICATION Timer Dimming LPU-120C Series Versatile control features: /circle6A Temperature sensor(NTC thermistor) protects the LED fromover temperature; /circle612V/100mA Auxiliary output can be used to power auxiliary loads such as active cooler or external dimming controller; /circle6Accepts various manner to dim the output current and the dimming range is 5% to 100% Iout; /circle6Support shut down functions at dimming applications. TYPICAL CHARACTERISTICS CURVE Power Factor VS. Load Efficiency VS. Load

www.pairuigroup.com Page: 7 / 8 Date: 04/29/2014 Constant current LED Drivers For outdoor use LPU-120C Series, 120Watt TYPICAL CHARACTERISTICS CURVE Output Current VS. Dimming Voltage Output Current VS. Exter nal Resistor Output current VS. Duty Cycle of PWM Signal Output Current VS . Running Time Current Reduction VS. Thermistor Resistance Value

www.pairuigroup.com Page: 8 / 8 Date: 04/29/2014 Constant current LED Drivers For outdoor use LPU-120C Series, 120Watt MECHANICAL No Dimming & Timer Dimming Version Unit: mm 0~10Vdc or Resistor Dimming & PWM Dimming Version Unit: mm