Rev. 06.15.07 LPT60-M Series 1 of 3 Embedded Power for Business-Critical Continuity LPT60-M Series
60 Watts
- Medical safety approvals
- Universal input
- 3" x 5" footprint
- Remote sense on main output
- Built-in EMI filter
- Low output ripple
- Adjustable 5V output
- Overvoltage protection
- Overload protection
- 110KHz switching frequency
- LPX60 enclosure kit available Total Power: 60 - 80 Watts Input Voltage: 85 - 264 VAC 120 - 300VDC # of Outputs: Triple Electrical Specifications Safety Input Input ra nge 85-264VAC 120-300VDC Frequency 47-440Hz Inrush current <18A peak @ 115VAC; <36A peak @ 230VAC, cold start @ 25°C Input current 1.5A max. (RMS) @ 115VAC Efficiency 70% typical at full load EMI FCC Class A conducted; CISPR 22 Class A conducted EN55022 Class A conducted; VDE 0878 PT3 Class A conducted Safety ground leakage current <75μA max. @ 50/60 Hz, 264VAC input Output Maximum Power 60W for convection; 80W with 30CFW forced air Cross regulation ±2% on output 1; ±5% on outputs 2, 3 Adjustment range -5, +10% minimum Hold-up time 20ms @ 60W load, 115VAC nominal line Overload protection Short circuit protection on all outputs. Case overload protected @ 110% to 145% above peak rating Overvoltage protection 5.7 to 6.7 VDC on the main output Remote sense Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. VDE 0750/EN60601-1 (IEC601) 21310-3336-0015 UL UL2601 E182560 CSA CSA 22.2 No. 601.1 LR109492 CE Mark (LVD) RoHS
Rev. 06.15.07 LPT60-M Series 2 of 3 Embedded Power for Business-Critical Continuity
Ordering Information
Peak Load1 Regulation2 Ripple P/P (PARD)3 LPT62-M +5V +12V -12V 0.7A 0.3A 0.7A 3.5A 10A 1.5A ±2% ±5% ±5% 50mV 120mV 120mV LPT63-M +5V +15V -15V 0.7A 0.3A 2.8A 0.7A 3.3A 10A 1.5A ±2% ±5% ±5% 50mV 150mV 150mV 1. Peak current lasting <30 seconds with a maximum 10% duty cycle. 2 . At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3 . Peak-to-peak with 20 MHz bandwidth and 10μF in parallel with a 0.1μF capacitor at rated line voltage and load ranges. 4. Minimum Loads are required. Operating temperature: 0° to 50°C ambient derate each output at 2.5% per degree from 50° to 70°C, -20°C startup Electromagnetic susceptibility: Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Humidity: Operating; non-condensing 5% to 95% Vibration: Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75G peak 5 Hz to 500 Hz, operational Storage temperature: -40° to 85°C Temperature coefficient: ±.04% per °C MTBF demonstrated: >550,000 hours at full load and 25°C ambient conditions Environmental Specifications
Rev. 06.15.07 LPT60-M Series 3 of 3 Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2007 Emerson Electric Co. Embedded Power for Business-Critical Continuity Emerson Network Power. The global leader in enabling business-critical continuity. EmersonNetworkPower. com AC Power Connectivity DC Power Embedded Power Inbound Power Integrated Cabinet Solutions Outside Plant Precision Cooling Site Monitoring and Services Mechanical Drawing Americas
5810 Van Allen Way
Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Asia (HK) 16th - 17th Floors, Lu Plaza
2 Wing Yip Street, Kwun Tong
Kowloon, Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 For global contact, visit: www.astecpower.com www.artesyn.com technicalsupport@astec.com technicalsupport@artesyn.co m While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Printed in U S A Pin Assignments Connector LPT62-M LPT63-M SK1-1 Neutral Neutral SK1-3 Line Line SK2-1 +12V +15V SK2- 2 +5V +5V SK2- 3 +5V +5V SK2-4 Common Common SK2-5 Common Common SK2-6 -12V -15V SK201-1 +Sense +Sense SK201-2 -Sense -Sense Mating Connectors AC Input: Molex 09-50-8031 (USA) 09-91-0300 (UK) PINS: 08-58-0111 DC Outputs: Molex 09-50-8061 (USA) 09-91-0600 (UK) PINS: 08-52-0113 Remote Sense: Molex 22-01-2025 PINS: 08-52-0113 Astec Connector Kit #70-841-006, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is ±0.02" (±0.5mm) 3. Mounting holes M1 and M2 should be grounded for EMI purposes. 4. Mounting hole M1 is safety ground connection. 5. Specifications are for convection rating at factory settings at 115 VAC input, 25°C unless otherwise stated. 6. Warranty: 2 year 7. Weight: 0.75lbs/0.34kg