Rev. 01.14.12_#43 LPQ200-M Series 1 of 3 Embedded Power for Business-Critical Continuity LPQ200-M Series

200 Watts

  • Medical and ITE safeties
  • Active power factor correction
  • 3” x 5” footprint
  • Less than 1U high
  • EN61000-3-2 compliant
  • Remote sense
  • Power fail
  • Adjustable outputs
  • Built-in Class B EMI filter
  • Overvoltage protection
  • Overload protection
  • Thermal overload protection
  • LPX200 enclosure kit available Total Power: 100 - 200 Watts Input Voltage: 90 - 264 Vac # of Outputs: Quad Electrical Specifications Safety Input Input ra nge: 90 - 264 Vac; 120 - 300 Vdc Frequency: 47 - 63 Hz Inrush current: 50 A max., cold start @ 25 °C, 230 Vac input Efficiency: 84% typical at full load EMI/RFI: FCC Class B conducted; CISPR22 Class B conducted; EN55022 Class B conducted; VDE0878PT3 Class B conducted Safety ground leakage current: 275 uA @ 50/60 Hz, 264 Vac input Output Maximum power: 100 W for convection ; 200 W with 30CFM forced air Adjustment range: All outputs -20%, +10%, except for the 3.3 V output which will be -15%, +10% (LPQ201-M) Hold-up time: 16 ms @ 200 W load, 120 Vac input Overload protection: Short circuit protection on all outputs. V1, V2 & V3 overload protected @ 110 - 160%. V4 is 150 - 250% above rating Overvoltage protection: 30 - 50% above nominal output on V1 (and V2 on LPQ202) Logical Control Power failure: Active low logic signal goes high 100-500 msec after main output; it goes low at least 6 msec before loss of regulation Remote sense: Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected.
  • TUV 60950, 60601-1
  • UL 60950, 60601-1
  • CSA 60950, 60601-1
  • CB Certificate & report
  • CE Mark (LVD)

Business-Critical Continuity

Ordering Information

P/P (PARD)3 LPQ201-M +3.3 V 0 A 13 A 18 A 20 A ± 2% 50 mV +5 V 0 A 13 A 18 A 20 A ± 5% 50 mV +12 V 0 A 5 A 9 A 10 A ± 5% 120 mV -12 V 0 A 1 A 2 A 2.5 A ± 5% 120 mV LPQ202-M +5 V 0 A 13 A 18 A 20 A ± 2% 50 mV +12 V 0 A 5 A 9 A 10 A ± 5% 120 mV +24 V 0 A 1.5 A 3 A 3.5 A ± 7% 240 mV -12 V 0 A 1 A 2 A 2.5 A ± 5% 120 mV 1. Peak current lasting < 30 seconds with a maximum 10% duty cycle. 2 . At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3 . Peak-to-peak with 20 mHz bandwidth and 10 µF (tantalum capacitor) in parallel with a 0.1 µF capacitor at rated line voltage and load ranges. Rev. 01.14.12_#43 LPQ200-M Series 2 of 3 Operating temperature: 0° to 50 °C ambient derate each output as 2.5% per degree from 50° to 70 °C. -20 °C start up Storage temperature: -40 °C to +85 °C Electromagnetic susceptibility: Designed to meet EN61000-4; Humidity: Operating; non-condensing 10% to 90% RH, non-operating, non-condensing 10 - 95% Vibration: IEC68-2-6 to the levels of IEC721-3-2 MTBF calculated: 516,000 hours at full load and 25 °C ambient conditions. 230 Vac input, Bellcore Environmental Specifications Pin Assignments Connector LPQ200-M SK1 Pin 1 Neutral Pin 3 Line SK2 Pin 1 V1 OUT Pin 2 V2 OUT Pin 3 GND OUT Pin 4 GND OUT Pin 5 GND OUT Pin 6 GND OUT Pin 7 V3 OUT Pin 8 V4 OUT SK3 Pin 1 +V1 Remote sense Pin 2 -V1 Remote sense Pin 3 N/C Pin 4 N/C Pin 5 +Power fail Pin 6 Common Pin 7 N/C Pin 8 Common Pin 9 +V2 Remote Sense (LPQ201-M only) Pin 10 -V2 Remote Sense (LPQ201-M only) Mating Connectors AC Input (SK1): Molex 09-50-8031 (connector) PINS: 08-52-0113 AC Ground: Molex 01-90020001 DC Output (SK2): Terminal block Wire size based on Cable Ampacity/AWG Control Signals (SK3): Molex 90142-0010 (USA) PINS: 90119-2110 or LANDWIN: 2580S0803 PINS: 2583T021V Emerson Network Power Connector Kit #70-841-027, includes all of the above. 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is ± 0.02” (± 0.5 mm) 3. Mounting holes MH1 and MH2 should be grounded for EMI purposes. 4. Mounting hole MH1 is safety ground connection. 5. Specifications are for convection rating at factory settings at 115 VAC input, 25 °C unless otherwise stated. 6. This power supply requires mounting on metal standoffs 0.20” (5 m) in height. 7. Warranty: 2 years 8. Weight: 1.5 lbs/0.68 kg

Rev. 01.14.12_#43 LPQ200-M Series 3 of 3 Embedded Power for Business-Critical Continuity Mechanical Drawing 100W Output Voltage Adjust POTs 2.55 (64.8) 3.00 (76.2) 0.224 (5.7) (4X) 0.224 (5.7) (4X) 5.00 (127) 4.55 (115.6) PIN - 5 PIN - 10 PIN - 1 PIN - 8 SK3 SK2 Ø4 (4X) Mounting Hole V4 Adjust POT PIN - 1 Ground Tab PIN - 3 SK1 0.06 (1.5) (2X) 0.098 (2.5) MH1 Safety Gnd V1 Pot Adj V2 Pot Adj. V3 Pot Adj Americas

5810 Van Allen Way

Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Asia (HK) 14/F, Lu Plaza

2 Wing Yip Street

Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 For global contact, visit: www.Emerson.com/EmbeddedPower techsupport.embeddedpower @emerson.com While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Emerson and the Emerson Network Power logo are trademarks of Emerson Electric Co. ©2012 Emerson Electric Co. All rights reserved. EmersonNetworkPower.com Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power