Technical Support: (888) 41-ASTEC or (407) 241-2752 Americas: (760) 930-4600 Europe (UK) 44 (1384) 842-211 Asia (HK) 852-2437-9662 121 Special Features Electrical Specs
175 Watts
Total Power: 110-175 Watts Input Voltage: 85-264 VAC 120-300 VDC # of Outputs: Quad
- Active power factor correction
- IEC EN61000-3-2 compliance
- Adjustable outputs on 1, 3 & 4 Remote sense on main output
- Single wire current sharing
- Power fail and remote inhibit
- Built-in EMI filter
- Low output ripple
- Overvoltage protection
- Overload protection
- Thermal overload protection
- DC power good
- 5 V standby output
- Adjustable floating 4th output
- Optional cover (-C suffix) Operating temperature: 0° to 50°C ambient Low temperature start -20°C Derate each output at 2.5% per degree from 50° to 70°C (except for -C version) Electromagnetic susceptibility: designed to Level 3 Humidity: Operating; non-condensing 5% to 95% Vibration: Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75 G peak 5 Hz to 500 Hz, operational Storage temperature: -40° to 85°C Temperature coefficient: ± .04% per °C MTBF demonstrated: >550,000 hours at full load and 25°C ambient conditions Input Input range 85-264 VAC, 120-300 VDC Frequency 47-63 Hz Inrush current 38 A max, cold start @ 25°C Efficiency 75% typical at full load EMI filter Meets FCC Class B conducted CISPR 22 Class B conducted EN55022 Class B conducted VDE 0878 PT3 Class B conducted Power factor 0.99 typical Safety ground leakage current 1.0 mA @ 50/60 Hz, 264 VAC input Output Maximum power 110 W convection (75 W with cover LPQ172)
85 W convection - LPQ173
175 W with 30 CFM forced air
(130 W with cover - LPQ172 only) Adjustment range 3.3 - 5.5V on main; -12 - 15V on 3rd output 3.3 - 25 V on 4th output- LPQ172 3.3 - 5.5V on 4th output on LPQ173 Hold-up time 20 ms @175 W load at nominal line Overload protection Short circuit protection on all outputs. Case overload protected @ 110-145% above peak rating Overvoltage protection Tracks outputs 1, 3 & 4; 15 to 35% Standby output 5 V @ 200 mA regulated ±5% Logic Control AC power failure TTL logic signal goes high 100 - 500 msec after V1 output; It goes low at least 4 msec before loss of regulation Remote inhibit Requires contact closure to inhibit outputs Remote sense Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. DC -OK TTL logic signal goes high after main output is in regulation. It goes low when there is a loss of regulation Environmental Safety VDE 0805/EN60950/IEC60950 UL 60950 CB Certificate and report CSA CSA 60950 Level 3 CE Mark (LVD) NEMKO EN 60950/EMKO-TSE rev 09.20.04
Astec House, Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX, UK Telephone: 44 (1384) 842-211 Facsimile: 44 (1384) 843-355 AMERICAS
5810 Van Allen Way
Carlsbad, CA 92008 Telephone: 760-930-4600 Facsimile: 760-930-0698 122 www.astecpower.com
Ordering Information
Units 2111-2116, Level 21 Tower1, Metroplaza 223, Hing Fong Road Fwai Fong, New Territories Hong Kong Telephone: 852-2437-9662 Facsimile: 852-2402-4426 Model Output Minimum Maximum Load with Maximum Load with Peak Regulation2 Ripple Number Voltage Load Convection Cooling 30 CFM Forced Air Load P/P(PARD)3 LPQ172 5 V (3.3 - 5.5 V) 0 A 15 A 30 A 32 A ±2% 50 mV
12 V 0 A 6 A 8 A 10 A ±3% 120 mV
-12 V (-12 -15 V) 0 A 1.5 A 3 A 3.5 A ±3% <1% ±3.3-25 V 0.5 A* 2 A 5 A 5.5 A ±3% <50mV or 1% LPQ173 5 V (3.3 - 5.5 V) 0 A 10 A 24 A 26 A ±2% 50 mV -12 V (-12 -15 V) 0 A .2 A 3 A 3.5 A ±3% <1% 5 V (3.3 - 5.5 V) 0 A 10A 24 A 26 A ±2% 50mV 1. Peak current lasting <30 seconds with a maximum 10% duty cycle. 2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges. 4. 4th output adjustable 3.3-25 V factory set at 5 V. 5. *Minimum loads are required when output set below 5 Volts 6. Remote inhibit resets OVP latch 7. LPQ173-C has no convection rating. Note: -C suffix added to the model number indicates cover option and is limited to 50C operation. Connector LPQ172 LPQ173 SK1 PIN 1 N/C V4 SWP PIN 2 5V Standby 5V Standby PIN 3 N/C +V4 Sense PIN 4 V1 SWP V1 SWP PIN 5 Common Common PIN 6 +V1 sense +V1 sense PIN 7 Sense common Sense common PIN 8 Remote inhibit Remote inhibit PIN 9 DC power good DC power good PIN 10 POK POK SK2 PIN 1,2 +12 V +12V PIN 3,4,5 Common Common PIN 6 -12 V -12V PIN 7 POK POK PIN 8 +3.3 V to +25 V (Float) N/C PIN 9 Common (Float) N/C SK3 TB-1, 3 COMMON COMMON TB-2 +5 V (3.3V to 5.5V) +5V (3.3V to 5.5V) TB-4 N/C +5 (3.3V to 5.5V) SK4 PIN 1 GROUND GROUND PIN 3 LINE LINE PIN 5 NEUTRAL NEUTRAL Mating Connectors (SK4) AC Input: Molex 09-50-8051 (USA) Molex 09-91-0500 (UK) PINS: 08-58-0111 (SK3) Main output: Molex BB-124-08 (SK2) Aux DC Output/Power fail: Molex 09-50-8091 (USA) Molex 09-91-0900 (UK) PINS: 08-58-0111 (SK1) Control Signals: Molex 90142-0010 (USA) PINS: 90119-2110 or Amp: 87977-3 PINS: 87309-8 Astec connector kit #70-841-015, includes all of the above. Pin Assignments LPQ170 Series
Astec House, Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX, UK Telephone: 44 (1384) 842-211 Facsimile: 44 (1384) 843-355 AMERICAS Carlsbad, CA 92008 Telephone: 760-930-4600 Facsimile: 760-930-0698 123www.astec.com Mechanical Drawing ASIA Units 2111-2116, Level 21 Tower1, Metroplaza 223, Hing Fong Road Fwai Fong, New Territories Hong Kong Telephone: 852-2437-9662 Facsimile: 852-2402-4426 Notes: 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is ±0.02”. 3. Specifications are for convection rating at factory settings unless otherwise stated. 4. Mounting screw maximum insertion depth is 0.12”. 5. Warranty: 1 year 6. Weight: 2 lb / 0.91 kg SK2 SK1 SK3 LPQ170 Series