LPQ142 ASTEC | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
Technical Support: (888) 41-ASTEC or (407) 241-2752 Americas: (760) 930-4600 Europe (UK) 44 (1384) 842-211 Asia (HK) 852-2437-9662 110 Special Features Electrical Specs rev 08.24.04
145 Watts
Total Power: 110-145 Watts Input Voltage: 85-264 VAC 120-300 VDC # of Outputs: Quad
- Active power factor correction
- IEC EN61000-3-2 compliance
- Adjustable outputs on 1, 3 & 4 Remote sense on main output
- Single wire current sharing
- Power fail and remote inhibit
- Built-in EMI filter
- Low output ripple
- Overvoltage protection
- Overload protection
- Thermal overload protection
- Adjustable floating 4th output
- Optional cover (-C suffix)
- Optional fan cover (-CF suffix) Operating temperature: 0° to 50°C ambient derate each output at 2.5% per degree from 50° to 70°C Electromagnetic susceptibility: designed to meet Humidity: Operating; non-condensing 5% to 95% Vibration: Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances
0.75 G peak 5 Hz to 500 Hz, operational
Storage temperature: -40° to 85°C Temperature coefficient: ± .04% per °C MTBF demonstrated: >550,000 hours at full load and 25°C ambient conditions Input Input range 85-264 VAC, 120-300 VDC Frequency 47-63 Hz Inrush current 38 A max, cold start @ 25°C Efficiency 75% typical at full load EMI filter Meets FCC Class B conducted CISPR 22 Class B conducted EN55022 Class B conducted VDE 0878 PT3 Class B conducted Power factor 0.99 typical Safety ground leakage current 1.0 mA @ 50/60 Hz, 264 VAC input Output Maximum power 80 W convection (60 W with cover-C)
145 W with 30 CFM forced air
(100 W with cover-C) Adjustment range 3.3 - 5.5V on main; -12 - 15V on 3rd output 3.3 - 25 V on 4th output Hold-up time 20 ms @145 W load at nominal line Overload protection Short circuit protection on all outputs. Case overload protected @ 110-145% above peak rating Overvoltage protection Tracks outputs 1, 3 & 4; 10 to 35% Logic Control AC Power failure TTL logic signal goes high 100 - 500 msec after V1 output; It goes low at least 4 msec before loss of regulation Remote inhibit TTL High disables output. Contact closure causes outputs to "bounce" Remote sense Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. DC -OK TTL logic signal goes high after main output is in regulation. It goes low when there is a loss of regulation VDE 60950 UL 60950 CB Certificate and report CSA 60950 CE Mark (LVD) NEMKO EN 60950/EMKO-TUE Environmental Safety
Astec House, Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX, UK Telephone: 44 (1384) 842-211 Facsimile: 44 (1384) 843-355 AMERICAS
5810 Van Allen Way
Carlsbad, CA 92008 Telephone: 760-930-4600 Facsimile: 760-930-0698 111 www.astecpower.com
Ordering Information
Units 2111-2116, Level 21 Tower1, Metroplaza 223, Hing Fong Road Fwai Fong, New Territories Hong Kong Telephone: 852-2437-9662 Facsimile: 852-2402-4426 Model Output Minimum Maximum Load with Maximum Load with Peak Regulation 2 Ripple Number Voltage Load Convection Cooling 30 CFM Forced Air Load P/P(PARD) 3 LPQ142 5 V (3.3 - 5.5 V) 0 A 12 A 25 A 27 A ±2% 50 mV
12 V 0 A 5 A 6 A 9 A ±3% 120 mV
-12 V (-12 -15 V) 0 A 1 A 1.5 A 2 A ±3% <1% ±3.3-25 V 0.5 A 1.5 A 4.5 A 5 A ±3% <50mV or 1% 1. Peak current lasting <30 seconds with a maximum 10% duty cycle. 2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges. 4. 4th output adjustable 3.3-25 V factory set at 5 V. 5. *Minimum loads are required when output set below 5 Volts 6. Remote inhibit resets OVP latch Note: -C suffix added to the model number indicates cover option. -CF suffix added to the model number indicates fan cover option. (4X) 63.5 1.5 (38.1) (3X) 19.1 29.1 161.5 171.5 7.0 (177.8) (2X) 6.4 (2X) 119.6 (2X) 139.7 SK1 N L GND SK6 SK2 MAIN OUTPUT 4.00 (101.6) #6-32 #6-32 #6-32 (8 places)M3 (8 places) 6 10 1 5 1 6 +12V OUT COMM -12V OUT COMM V4+ V4- -CF option Connector LPQ142 SK1 PIN 1 GROUND PIN 3 NEUTRAL PIN 5 LINE SK2 PIN 1 +12 V PIN 2 COMMON PIN 3 -12 V PIN 4 COMMON PIN 5 +5 V to +25 V (Float) PIN 6 COMMON (Float) SK4 TB-1 COMMON TB-2 +5 V SK6 PIN 1 N/C PIN 2 DC OK PIN 3 N/C PIN 4 V1 SWP PIN 5 Common PIN 6 +V1 sense PIN 7 Sense common PIN 8 + inhibit PIN 9 - inhibit PIN 10 Power fail Mating Connectors (SK1) AC Input: Molex 09-50-8051 (USA) Molex 09-91-0500 (UK) PINS: 08-58-0111 (SK2) Aux DC Output: Molex 09-50-8061 (USA) Molex 09-91-0600 (UK) PINS: 08-58-0111 (SK6) Control Signals: Molex 90142-0010 (USA) PINS: 90119-2110 or Amp: 87977-3 PINS: 87309-8 (SK4) Main output: Molex BB-124-08 Astec connector kit #70-841-017, includes al of the above. Notes: 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is ±0.02”. 3. Specifications are for convection rating at factory settings unless otherwise stated. 4. Mounting screw maximum insertion depth is 0.12”. 5. Warranty: 1 year 6. Weight: 1.63 lb / 0.74 kg Pin Assignments LPQ142 Series