Features

  • Certified for Class 1, Div 2 (Zone 2), Group A, B, C, D Hazardous Areas
  • Low profile package saves space
  • Excellent resistance to shock and vibration
  • 30mm standard through shaft, PEEK reduction hub available
  • High protection level of IP66
  • High performance in temperatures from –40°C to +85°C
  • Resolutions up to 10,000 PPR, incremental or 16 BITS absolute
  • Terminal box, M12 or cable output terminations
  • Encapsulated electronics
  • TTL and HTL electronics
  • Reinforced electrical output available on some incremental and absolute models
  • Wiring fault tolerant with terminal box connection
  • Long cable drive capability Housing Size Standard: Ø 90mm X 26mm deep Terminal Box: 128mm tall X 116mm wide X 25mm deep. (See dimensional drawings for detail) Shaft Size Hollow Shaft: Ø 1/2” to Ø 30 mm” blind or through Solid Shaft: Ø12 mm x 20 mm with keyway, Ø 3/8“x 7/8“ with flat Hollow Shaft w/ Integrated Coupling: 14mm, 20mm, 1/2”, 3/4” Permissible Shaft Loads Axial: 40 N Radial: 80 N Shaft Runout Hollow Shaft: 0.1 mm [0.004”] TIR Solid Shaft: 0.02 mm [0.001”] TIR Hollow Shaft w/ Integrated Coupling: N/A (B) Static/ Dynamic Torque 30 / 300 mN.m [4.2/ 42 oz-in] @ 25°C Bearings 6807 - Sealed Material Cover: Clear anodized aluminum Body: Clear anodized aluminum Shaft: AISI 303 stainless steel Bearing Life L10h (Theoretical Mechanical Lifetime) > 18 X 109 turns / 100000 hours Continuous Max. Speed 6000 RPM, (Reference Chart 1. Speed vs Temperature) Shaft Moment of Inertia < 84000 g.mm2 [11.9 x 10-3 oz*in*sec2 ] Weight (approx.) Terminal Box: 790g M12 or cable: 450g

www.sensata.com Page 2 Copyright © 2022 Sensata Technologies, Inc. Electrical Cable or M12 Connection Shaft Options Through Hollow Shaft Blind Hollow Shaft Shaft with Integrated coupling Solid Shaft TEMPERATURE ELEVATION (°C) SPEED (RPM) 0 1000 2000 3000 4000 5000 6000 7000 Chart 1. Speed vs Temperature (Temperature on this chart to be added to ambient temperature. Do not exceede maximum temperature on datasheet.) Absolute Incremental Output Format SSI compatible (RS422) Two channels in quadrature + index and complements Resolution Up to 16 BITS Up to 10,000 CPT Encoder Accuracy ±0.1° Supply Voltage Vcl 5-30 Vdc Cable or M12: 5-30V (28/V) and 4.75-30V (28/5) Terminal Box: 11-30V (28/VR),5-30V (28/V) and 4.75- 30V (28/5) Supply Current (No Loads) 75mA Typ Cable or M12: 75mA Terminal Box: 100mA (28/VR), 75mA (28/V and 28/5) Current Per Channel Pair 40mA max Cable or M12: 40mA Terminal Box: 60mA (28/VR), 40mA (28/V and 28/5) Voltage / Output 28/SI: SSI RS485 w/o parity 28/SR: SSI RS485 reinforced w/o parity Terminal Box version only 28/V: Line driver 5-30 V In/Out; PushPull 28/5: Line driver with 5 V (TTL) regulated output 28/VR: Push Pull 11-30V reinforced. Terminal Box version only Short Circuit Proof 28/SI: Yes (except to V+) 28/SR: Yes Cable or M12: Yes (28/V) and Yes (except to Vcl) (28/5) Terminal Box: Yes (28/VR), (28/V) and (28/5) except to Vcl Reverse Polarity Tolerant Yes Wiring Fault Tolerant & Overvoltage Prot. 28/SI: No 28/SR: Yes Cable or M12: No Terminal Box: Yes Up to 60Vdc (28/VR) and No (28/V and 28/5) Frequency Response Cable or M12: Up to 1MHz Terminal Box: Up to 300kHz (28/VR), Up to 1MHz (28/V and 28/5) Output Terminations Cable, M12 or Terminal Box EMC EN 61000-6-2 : 2005, see user manual for details EN 61000-6-4 : 2017 + A1 : 2011, see user manual for details Isolation 1000V

www.sensata.com Page 3 Copyright © 2022 Sensata Technologies, Inc. INDEX GATED WITH A & B HIGH (CODE Q28) 90° A Z B INDEX GATED WITH B LOW (CODE Q29) 180° A Z B OUTPUT WAVEFORMS Waveform AA/ BB/ 00/ Channel B before A Clockwise (US convention is A leads B CCW) Absolute SSI WaveformIncremental Waveform Environmental CW Rotation Viewing Shaft CW Rotation Viewing Shaft Protection Class (sealing) IP66 Temperature Range Temp. Range: -40°C to +85°C Mechanical Resistance Shock (EN60068-2-27): ≤ 3000m.s-2 (5 ms, half sine) (300 G’s) Vibration (EN60068-2-6): ≤ 200m.s-2 (55 … 2 000 Hz) (20 G’s) Humidity 98% RH without condensation DIMENSIONS (A) NOTE: CHc : Hexagonal Socket head cap screws HC : Hexagonal socket set screws Through hollow shaft All dimensions are in millimeters [inches] 2.09 41.5

1.63 R45

1.77 43.5 1.71 35.5 1.398 1.61 10++ 0.150.05 .394++ .006.002 .24 120° 120° 78 B.C. 3.07 30 H7 1.181 1.38 60- 0.01 0.06 2.362- .0004 .0024 5.5 .22 .55 .16 3xM5 0.5 .02 .08 8.5 .33 1.77

www.sensata.com Page 4 Copyright © 2022 Sensata Technologies, Inc. Shaft with integrated coupling Solid shaft Blind hollow shaft 2.09 41.5 1.77 35.5 1.398 1.61 10++ 0.150.05 .394++ .006.002 .24 43.5 1.71 120° 120° 78 B.C. 3.07 60- 0.01 0.06 2.362- .0004 .0024 5.5 .22 .55 .16 3xM5 0.5 .02 .08 5.5 .22 31.5 1.24 12 to 30 H7 [0.500 to 1.125 H7] .59 2.09 1.61 39.5 1.56 R45 1.77 10++ 0.150.05 .394++ .006.002 120° 120° 78 B.C. 3.07 41.5 1.63 M12x1 1.02 .08 10 to 20 H7 [0.500 to 0.750 H7] 60- 0.01 0.06 2.362- .0004 .0024 .55 10 .39 2.09 1.61 R45 1.77 10++ 0.150.05 .394++ .006.002 .24 43.5 1.71 120° 120° 78 B.C. 3.07 41.5 1.63 1.02 .08 60- 0.01 0.06 2.362- .0004 .0024 .55 .39 12- 0.006 0.024 .472- .0002 .0009 0.05 .157+ .002 .000 17.5 .69 M5x12 at center 9.517 9.507 .3747 .3743 19.1 .75 22.4 .88 8.6 .34 3/8 in. shaft with flat

www.sensata.com Page 5 Copyright © 2022 Sensata Technologies, Inc. TERMINAL BOX SHAFT OPTIONS Through hollow shaft NOTE: CHc : Hexagonal Socket head cap screws HC : Hexagonal socket set screws Through Hollow Shaft Blind Hollow Shaft Shaft with Integrated coupling Solid Shaft .47 .79 3.54 2.36 3.35 2.76 53.5 2.11 49.5 1.95 116 4.57 128 5.04 2.99 62.5 2.46 ( 5 to 13) [0.20 to 0.51] cable size (not supplied) 30 H7 1.181 1.38 7.5 .3045 1.77 12.5 .49 60- 0.01 0.06 2.362- .0004 .0024 .08 0.5 .02

www.sensata.com Page 6 Copyright © 2022 Sensata Technologies, Inc. Blind hollow shaft Shaft with integrated coupling .47 .79 3.54 2.36 3.35 2.76 53.5 2.11 49.5 1.95 116 4.57 128 5.04 2.99 62.5 2.46 ( 5 to 13) [0.20 to 0.51] cable size (not included) 5.7 .22 60- 0.01 0.06 2.362- .0004 .0024 .98 .08 0.5 .02 12.5 .4912 to 30 H7 0.500 to 1.125 H7 21.1 .83 6.7 .26 116 4.57 62.5 2.46 = 70 = 2.76 1.93 2.13 128 5.04 2.99 5 to 13 [0.20 to 0.51] cable size (not supplied) 3.54 .98 .08 5.6 .22 14.5 .57 60- 0.01 0.06 2.362- .0004 .0024 10 to 20 H7 [0.50 to 0.75 H7) 6.2 .24 2X M6 .31 5.5 .21 Mounting Bolt Detail

www.sensata.com Page 7 Copyright © 2022 Sensata Technologies, Inc. TETHER OPTIONS FOR STANDARD CABLE OR M12 CONNECTOR Other options available, consult factory. Tethers come with all the hardware shown. T2- Long tether arm with ¼”-20 adj. hardware – M9445/053-02 T3-Short tether arm with ¼”-20 adj, hardware (fits 56C) – M9445/058-02 2,17 0,98 44,5 1,75 0,47 18.3 / 28.3 0,72 / 1.11 1/4"-20 with hex nuts 2,99 102 4,02 155 6,10 118 4,65 144 5,67 1,02 0,47 30° Typ 72,4 2,85 77,4 3,05 0,47 1,02 90,2 3,55 30° Typ 0,98 44,5 1,75 18.3 / 28.3 0,72 / 1.11 0,47 1,97 1/4"-20 x 2" with hex nuts Solid shaft 116 4.57 62.5 2.46 = 70 = 2.756 2.99 5 to 13 [0.20 to 0.51] cable size (not supplied) 3.543 2.13 1.93 128 5.04 .98 14.5 .57 .08 17.5 .69 4+0.1 .157+ .002 .000 12- 0.006 0.024 .472- .0002 .0009 60- 0.01 0.06 2.362- .0004 .0024 5.6 .22 9.517 9.507 .3747 .3743 22.4 .88 19.1 .75 8.6 .34 3/8 in. Shaft with Flat

www.sensata.com Page 8 Copyright © 2022 Sensata Technologies, Inc. Connection Incremental Connection Absolute SSI Incremental Absolute Termination Connection Ordering Code Description - + A B Z A/ B/ Z/ Case Ground M12 M12 EUR M12 - 8 pins 1 2 3 4 5 6 7 8 Connector Body Standard Cable SG PVC Jacket BLK RED YEL BLU ORN WHT/ YEL WHT/ BLU WHT/ ORN GRN Terminal Box T Terminal box - 9 pins 1 2 3 4 5 6 7 8 9 TERMINATIONS Other cable types available- Consult factory TETHER OPTIONS FOR TERMINAL BOX OUTPUT T4- Standard Fork is provided for all blind or through hollow shaft versions T5- M9445/059-02 Standard Fork + 56C Face Pin 0,79 0,47 56C Face radius 74.6 2,81 2,40 3,23 50,8 2,00 24,5 0,96 12 min. 0,47 min. 0,47 3 min. 0,12 min. 1/4"-20 with hex nuts 0,79 0,47 56C Face radius 74.6 2,81 2,40 3,23 0,87 0,08 3,35 2,5 0,10 Termination Connection Ordering Code Description - + Clk+ Clk- Data+ Data- Reset NC Case Ground M12 M12 EUR M12 - 8 pins 1 2 3 4 5 6 7 N/A Connector Body Standard Cable SG PVC Jacket BLK RED BLU WHT/ BLU YEL WHT/ YEL ORN N/A GRN Terminal Box T Terminal box - 9 pins 1 2 3 4 5 6 7 8 9 STANDARD RESOLUTIONS For non-standard and resolutions above 10000 PPR, please contact factory 32 64 100 128 250 256 360 500 512 600 720 1000 1024 1200 1250 1440 1500 2000 2048 2500 2880 3600 4096 5000 7200 8192 10000 BITS 5 6 7 8 9 10 11 12 13 14 15 16 Counts 32 64 128 256 512 1024 2048 4096 8192 16384 32768 65536

www.sensata.com Page 9 Copyright © 2022 Sensata Technologies, Inc. ORDERING OPTIONS - NORTH AMERICAN LP35 MODELS INCREMENTAL See standard resolution list, ex: 01024 ABSOLUTE See standard resolution list, ex: 12 Mounting Standard Outputs Output Termination Type Coupling / Tether Types Special Features XXXXX Example shows H30S for Metric and H4EP for Imperial H:Through Hollow Shaft (Includes collet clamp) 30S = 30mm (Non isolated) Less than 30mm with isolated reduction sleeve H4EP = ½” H5EP = ” H6EP = ¾” H7EP = ” H8EP = 1” H8ES = 1” no isolation B: Blind Hollow Shaft (Screws into mating shaft – screw provided) Non isolated versions standard. Isolated versions <30mm available, consult factory. B30S = 30 mm B4ES = ½” B5ES = ” B6ES = ¾” B7ES = ” B8ES = 1” C: Hollow Shaft with Integrated Coupling (all options insulated) C14P = 14 mm C20P = 20 mm C4EP = ½” C6EP = ¾” S: Shafted (Requires separate coupling) S12 = 12mm S3E = ” INCREMENTAL 28/V = Standard line driver 5-30V In / Out / PushPull 28/5 = Standard Line Driver with 5 volt (TTL) regulated output 28/VR = Push Pull 11-30V reinforced (only T version) Note: All versions are short-circuit protected. Reinforced electronics are short circuit and overvoltage protected ABSOLUTE 28/SI: SSI RS485 w/o parity 28/SR: SSI RS485 reinforced w/o parity Terminal Box version only S VERSION T0 = No tether = STD T2 = Long Tether Kit (56C) T3 = Short Tether Kit BOX VERSION T4 = Standard Fork is provided for all LP35-TB with blind or through hollow shaft T5 = M9445/059-02 Standard Fork + 56C Face hardware Other Tether arms may be ordered separately (Ex: Ball joint Tether M9230-04/XXX) consult with factory Family LP35 HN Housing Type Output Resolution LP35: Low Profile 90mm (3.5”) body size HN = Hazardous Area, Non-Incendive INCREMENTAL ABZC Q28 = Index with A&B High Q29 = Index gated with Neg B ABSOLUTE AB = Natural Binary AG = Gray Code Use this diagram, working from left to right to construct your model number (Example : LP35-HN-Q28-02048-H30S-28/V-SG060- T0) NOTE: (1)“T” Code changes the form from approximately 90mm (3.5”) round to a rectangle that is approximately 128mm (5”) high by 116mm wide (4.5”) BOX T= Terminal Box with cable gland.(1) STANDARD CABLE SGXXX = Cable gland seal. PVC jacket and US standard color code. SQPHHH = Polyurethane with EU Color Code (Not UL listed); STEHHH= Silicone with EU color code (Not UL listed); XXX=cable length in inches up to 120” in 6 inch increments; HHH = cable length in dm up to 100 dm in 5 dm increments CONNECTOR SM12 : European standard connector with EU color code SG18C18: US- MS3102R18-1P on end of 18” cable SGS18C12: US- MS3112E12-10P on end of 18” cable

www.sensata.com Page 10 Copyright © 2022 Sensata Technologies, Inc. AGENCY APPROVALS & CERTIFICATIONS GENERAL NOTES (A) For detailed installation instructions and recommend screw torques refer to the User’s Manual (B) For more information refer to the User Manual ACCESSORIES The following accessories are included with your LP series encoder as defined by your part number selection. These commodities, technology or software if exported from the United States must be in accordance with the Bureau of Industry and Security, Export Administration regulations. Diversion contrary to U.S. Law is prohibited. Class I, Div. 2, Gps A,B,C & D Cenelec II 3 G Ex nA IIC T4 Gc DEMKO 17 ATEX 1877X IECEx UL 17.0043X2004 / 108 / CE Ex nA IIC T4 Gc Bore Reduction Sleeve 9418/H20 = 20 mm bore 9418/H8E = 1 in. bore 9418/H7E =7/8 in. bore 9418/H6E = 3/4 in. bore 9418/H5E = 5/8 in. bore 9418/H4E = 1/2 in. bore 9418/H3E = 2/8 in. bore Integrated Coupling Kit (includes flex, hub and set screws) M9410/009-14 = 14 mm M9410/009-20 = 20 mm M9410/009-E3 =1/4 in. M9410/009-E4 = 1/2 in. M9410/009-E5 = 5/8 in. M9410/009-E6 = 1 in. Long Tether Arm Kit M9445/053 = long tether, M8x1 rod M9445/053-01 = long tether, 3/8”-16 rod M9445/053-02 = long tether, 1/4”-20 rod Short Tether Arm Kit M9455/058 = short tether, M8x1 rod M9455/058-01 = short tether, 3/8”-16 rod M9445/058-02 = short tether, 1/4”-20 rod Tether Pin Kit M9445/059 = M10x1.5 rod and hardware M9445/059-01 = 3/8”-16 rod and hardware M9445/059-02 = 1/4”-20 rod and hardware Key for 12mm slot 9435/006 = 4X4X12 mm key Cable Assemblies Length Model Number Part Number 0.5m 9416/111-8230/200-GM-005RAL-005-002 1m 9416/111-8230/200-GM-010RAL-010-012 2m 9416/111-8230/200-GM-020RAL-020-035 5m 9416/111-8230/200-GM-050RAL-050-045 10m 9416/111-8230/200-GM-100RAL-100-047 Ball End Tether M9230-04/XXX (XXX=Center-to-center nominal distance in mm) Flexible Couplings Bellows Type 9404/S/12-12 = for use with a 12mm shaft Triple Beam Type 39074-12-12 = for use with a 3/8” shaft

www.sensata.com Specification No. 02164-001 Page 11 CONTACT US Americas +1 (800) 350 2727 – Option 1 sales.beisensors@sensata.com Europe, Middle East & Africa +33 (3) 88 20 8080 position-info.eu@sensata.com Asia Pacific sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 Copyright © 2022 Sensata Technologies, Inc. Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, valuation, and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements, and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED, OR STATUTORY , INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY , FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY , AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA Rev:03/28/22 CONTROL DRAWINGS Accompanying the spec is a control drawing. This is specific for the Non-Incendive products from the LP35 family and consist of Installation Requirements, Special Conditions of Operation and a Certificate of Conformity. In these documents, the LP series models are referred to as HH_9, AH_9, HH_B, AH_B or HX_9, AX_9, HX_B, AX_B. Despite the difference in nomenclature, these are the same product specified under the LP35 nomenclature. Both the LP35 and the AH, HH, AX or HX model numbers will appear on the label of the finished product.

Nonincendive Magnetic Encoder Models : HH_9/AH_9/ HH_B/AH_B HX_9/AX_9/HX_B/AX_B SPECIAL CONDITIONS FOR SAFE USE The equipment shall be installed in an enclosure that provides a degree of protection not less than IP54 in accordance with IEC/EN 60079-15. Provision must be made to prevent the rated voltage being exceeded by transients of more than 140%. Power with (NEC) Class 2 supply. Encoders are intended to be used in an area of not more than pollution degree 2 ASSEMBLY CAUTION: DO NOT OPEN WHEN ENERGIZED For electrical installation use the standard EN/IEC 60079-14. For maintenance, use the standard EN 60079-17. The encoder must be returned to the manufacturer for repair or service. The unit is factory sealed and there are no adjustments or maintenance required. Electrical Ratings: 4.75-30Vdc, 7.6VA max EU Declaration of Conformity UL Declaration of Conformity Models HH_9, HX_9, AH_9, AX_9, HH_B, HX_B, AH_B and AX_B non-sparking/nonincendive variations are recognized components which comply with the following standards as defined in UL File E78446, Vol. 4 and shall be marked: Class I, Div. 2, Groups A,B,C,D and -40°C to +85° and T4 UL 121201, 9th Edition, Rev 2017-09-15, Nonincendive Electrical Equipment for Use in Class I and II, Division 2 and Class III, Divisions 1 and 2 Hazardous (Classified) Locations UL 508, 17th Ed., Rev. 2010-04-15, Industrial Control Equipment CSA C22.2 No. 213-17, 3rd Edition, Sept-2017, Nonincendive Electrical Equipment for Use in Class I and II, Division 2 and Class III, Divisions 1 and 2 Hazardous (Classified) Locations CAN/CSA C22.2 No. 14-10, 11th Ed., Rev. 2011-08-01, Industrial Control Equipment The notified organization responsible for the follow-up inspections for this UL recognized product is (assessed by): UL International (France) SA Espace Technologique de Saint-Aubin, Immeuble Explorer Route de l’Orme des Merisiers – F-91190 SAINT AUBIN Identification No. 675 NI Installation sheet AH_9/HH_9/AH_B/HH_B - P/N 2000/013 Rev. B UL – ATEX – IECEx certified BEI SENSORS Europe 9, rue de Copenhague Espace Européen de l’Entreprise-Schiltigheim BP 70044 - 67013 STRASBOURG Cedex France email: info@beisensors.com BEI SENSORS North America

1461 Lawrence Dr | Thousand Oaks, CA 91320 USA

Tel: 800-350-2727 or 805-716-0322 Fax: 800-960-2726 or 805-968-3154 email: beisales@beisensors.com www.beisensors.com BEI Sensors, certifies that non-sparking Models HH_9, HX_9, AH_9, AX_9, HH_B, HX_B, AH_B and AX_B and all resolutions, channel and output type options as noted on the IECEx and DEMKO certificates cited below, With the following inscriptions: II 3 G Ex nA IIC T4 Gc Designed and manufactured to comply with these directives: ATEX: 2014/34/EU and EMC: 2014/30/EU Complies with these standards: ATEX: EN60079-0:2018, EN60079-15:2010, IECEx: IEC60079-0:2017, IEC60079-15:2010 A comparative study of the standards EN 60079-0 (2012+A11 2013 and 2018), shows that the product is not concerned by the substantial modifications. As detailed in EC type examination certificates: DEMKO 17 ATEX 1877X and IECEx UL 17.0043X Product Quality Assurance Notification: LCIE 03 ATEX Q8060 Product Quality Assurance Report: FR/LCI/QAR08.0002 The following standards were also investigated for this certification: EN 60-529, NFC 23-520, NFC 23-539, EN 50081-1, EN 55022 classe B, EN 55014, EN 61000-6-2, CEI 61000-4-2, CEI 61000-4-3, CEI61000-4-4, CEI 61000-4-5, CEI 61000-4-6, CEI 61000-4-8, CEI 61000-4-11 The notified organization responsible for the follow-up of the ATEX directive is (assessed by): LCIE, B.P.8, F92260 Fontenay-aux-Roses Identification No. 0081 The company in charge of certification CEM is: LCIE BUREAU VERITAS, Aire de la Thur 68840 Pulversheim