Features

Housing Size 124 mm x 156 mm x 52 mm (see dimensional drawings for other configurations) Shaft Size Hollow Shaft: Ø 1/2” to Ø 1” blind or through Solid Shaft: Ø12 mm x 20 mm with keyway, Ø 3/8 “ x .78“ with flat Hollow Shaft w/ Integrated Coupling: 14mm, 20mm, 1/2”, 3/4” Permissible Shaft Loads Axial: 40 N [9 lbs] Radial: 80 N [18 lbs] Shaft Runout Hollow Shaft: 0.1 mm [0.004”] TIR Solid Shaft: 0.02 mm [0.001”] TIR Hollow Shaft w/ Integrated Coupling: N/A Static/ Dynamic Torque 30 / 300 mN.m [4.2/ 42 oz-in] @ 25°C Bearings 6807 - Sealed, deep groove ball bearing Material Cover: Hard anodized aluminum Body: Hard anodized aluminum Shaft : AISI 303 stainless steel Bearing Life L10h (Theoretical Mechanical Lifetime) > 18.109 turns / 100000 hours Continuous Max. Speed(A) 6000 RPM, (Reference Chart 1. Speed vs Temperature) Shaft Moment of Inertia < 130 000 g.mm2 [18.4 x 10-3 oz-in-sec2] Weight (aprox.) 1.6 kg [56.5 oz]

  • Designed for use in Class I, Div.1 & Zone 1 hazardous areas
  • Low profile package saves space
  • Excellent resistance to shock and vibration
  • 30mm standard through shaft, PEEK reduction hub available
  • High protection level of IP66
  • High performance in temperatures from –40°C to +100°C
  • Resolutions up to 10,000 PPR, incremental or 16 BITS absolute
  • Terminal box with Conduit Termination
  • Encapsulated electronics
  • TTL and HTL electronics
  • Reinforced electrical output available on some incremental and absolute models
  • Wiring fault tolerant with terminal box connection
  • Long cable drive capability

www.sensata.com Page 2 Copyright © 2022 Sensata Technologies, Inc. Protection Class (sealing) IP65 Temperature Range Operating -40°C to +85°C Storage -40°C to +100°C Mechanical Resistance Shock (EN60068-2-27): ≤ 3000m.s-2 (during 5 ms, half sine) Vibration (EN60068-2-6): ≤ 200m.s-2 (55 … 2 000 Hz) Humidity 98% RH without condensation Environmental TEMPERATURE ELEVATION (°C) SPEED (RPM) 0 1000 2000 3000 4000 5000 6000 7000 Electrical Absolute Incremental Output Format SSI compatible (RS422) Two channels in quadrature + index and complements Resolution Up to 16 BITS Up to 10,000 CPT Encoder Accuracy ±0.1° Supply Voltage Vcl 5-30 Vdc Supply Current (No Loads) 75mA Typ Current Per Channel Pair 40mA max Voltage / Output 28/SI: SSI RS485 w/o parity 28/SR: SSI RS485 reinforced w/o parity 28/V: Line driver 5-30 V In/Out; PushPull 28/5: Line driver with 5 V (TTL) regulated output 28/VR: Push Pull 11-30V reinforced Short Circuit Proof 28/SI: Yes (except to V+) 28/SR: Yes 28/V: Yes 28/5: Yes (except to Vcl) 28/VR: Yes Reverse Polarity Tolerant Yes Wiring Fault Tolerant & Overvoltage Prot. 28/SI: No 28/SR: Yes 28/V: No 28/5: No 28/VR: Yes Up to 60Vdc Frequency Response Up to 1MHz (28/V and 28/5) Up to 300kHz (28/VR) Output Terminations Enclosed terminal block, with three conduit fitting options: M16, ½” NPT, ¾”NPT EMC EN 61000-6-2 : 2005, see user manual for details EN 61000-6-4 : 2017 + A1 : 2011, see user manual for details Isolation 1000V Chart 1. Speed vs Temperature (Temperature on this chart to be added to ambient temperature. Do not exceede maximum temperature on datasheet.)

www.sensata.com Copyright © 2022 Sensata Technologies, Inc. Page 3 INDEX GATED WITH A & B HIGH (CODE Q28) 90° A Z B INDEX GATED WITH B LOW (CODE Q29) 180° A Z B OUTPUT WAVEFORMS Waveform AA/ BB/ 00/ Channel B before A Clockwise (US convention is A leads B CCW) Absolute SSI WaveformIncremental Waveform CW Rotation Viewing Shaft CW Rotation Viewing Shaft Through Hollow Shaft Blind Hollow Shaft Shaft with Integrated coupling Solid Shaft SHAFT OPTIONS DIMENSIONS (A) All dimensions are in millimeters [inches] All drawings: For dimensions A-E refer to Table 1

www.sensata.com Page 4 Copyright © 2022 Sensata Technologies, Inc. Shaft with integrated coupling Table 1 sleeve configuration M16 and ½” NPT Terminal Box ¾” NPT Terminal Box mm in mm in A 97 3.819 109 4.291 B 82 3.228 88.5 3.484 C 37.50 1.437 44 1.732 D 18.25 0.719 22.25 0.876 E 27 0.945 24 0.945 Through driving 124 4,882 4x 6,5 0,256 =110= 4,33162 2,441 E 1,841 B A =50= 1,969 11,5 max. 0,453 max. 10 to 20 +0,02 1/2 to 3/4 +0,001 0,000 33 max. 1,299 max. Through hollow shaft B A 124 4,882 4x 6,5 0,256 1,841 =110= 4,331 =50= 1,969 E 2,441 11,5 max. 0,453 max. 0,01 0,04 2,362 0,000 0,002 D 51,5 2,028 44,5 1,752 0,118 0,039 C 0,02 1,181 0,001 0,000 52,5 (with insulating sleeve) 2,067

www.sensata.com Copyright © 2022 Sensata Technologies, Inc. Page 5 Blind hollow shaft 124 4,882 4x 6,5 0,256 =110= 4,331 =50= 1,969 2,441 1,841 E A B 11,5 max. 0,453 max. 0,01 0,04 2,362 0,000 0,002 D 37,5 1,48 1,665 0,079 0,118 1,024 12 to 30 +0,02 1/2 to 1 1/6 +0,001 0,000 C Solid shaft 124 4,882 4x 6,5 0,256 =110= 4,331 =50= 1,969 2,441 1,841 A B E 11,5 max. 0,453 max. 0,01 0,04 2,362 0,000 0,002 D 0,079 37,5 1,476 0,01 0,02 0,472 0,000 0,001 0,472 +0,05 0,157 +0,002 0,000 0,079 0,748 0,787 C M5x12 Absolute Terminal Box Connection Incremental Terminal Box Connection - + Clk+ Clk- Data+ Data- Reset NC Ground 1 2 3 4 5 6 7 8 9 TERMINATIONS - + A B Z A/ B/ Z/ Ground 1 2 3 4 5 6 7 8 9 9.517 9.507 .3747 .3743 22.4 .88 19.1 .75 8.6 .34 3/8 in. Shaft with Flat

www.sensata.com Page 6 Copyright © 2022 Sensata Technologies, Inc. Incremental Absolute STANDARD RESOLUTIONS For non-standard and resolutions above 10000 PPR, please contact factory 32 64 100 128 250 256 360 500 512 600 720 1000 1024 1200 1250 1440 1500 2000 2048 2500 2880 3600 4096 5000 7200 8192 10000 BITS 5 6 7 8 9 10 11 12 13 14 15 16 Counts 32 64 128 256 512 1024 2048 4096 8192 16384 32768 65536 ORDERING OPTIONS - NORTH AMERICAN LP35 MODELS XX ex: 13 From 5 to16 BITS Incremental resolutions: See Table 2 Mounting Standard Outputs Output Termination Type Coupling / Tether Types Special Features XXXXX Example shows H30S for Metric and H4EP for Imperial H:Through Hollow Shaft (Includes collet clamp) H30S = 30mm (Non isolated) Less than 30mm with isolated reduction sleeve H4EP = ½” H5EP = ” H6EP = ¾” H7EP = ” H8EP = 1” H8ES = 1” no isolation B: Blind Hollow Shaft (Screws into mating shaft – screw provided) Non isolated versions standard. Isolated versions <30mm available, consult factory. B30S = 30 mm B5ES = ” B6ES = ¾” B7ES = ” B8ES = 1” C: Hollow Shaft with Integrated Coupling (all options insulated) C14P = 14 mm C20P = 20 mm C4EP = ½” C6EP = ¾” S: Shafted (Requires separate coupling) S12 = 12mm S3E = ” 28/SI = SSI RS485 w/o parity 28/SR = SSI RS485 reinforced w/o parity 28/V = Line driver 5-30 V In/Out; PushPull 28/5 = Line driver with 5 V (TTL) reulated output 28/VR = Push Pull 11-30V reinforced U0ER = M16 Tapped Hole U4ER = ½”-14 NPT Tapped Hole U6ER = ¾”-14 NPT Tapped Hole T0 = No tether TC= Ball joint tether (M9230-03/xxx Ball end tether arm (xxx = length in cm)) (Blank) = No special features Consult factory for available special features Family LP35 Housing Type Output Resolution LP35 = Low Profile Aluminum Body HC = Explosion Proof ABSOLUTE AB = Natural Binary AG = Gray Code INCREMENTAL Q28 A&B + Index and Complements. Index with A&B high. A before B CCW Q29 Index with B low Use this diagram, working from left to right to construct your model number (Example : LP35-HC-AB-13-H30S-28/SI- U0ER-T0)

Specification No. 02162-001 Rev:03/28/22 Page 7 www.sensata.com CONTACT US Americas +1 (800) 350 2727 – Option 1 sales.beisensors@sensata.com Europe, Middle East & Africa +33 (3) 88 20 8080 position-info.eu@sensata.com Asia Pacific sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 Copyright © 2022 Sensata Technologies, Inc. Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY , INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY , FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. CONTROL DRAWINGS Accompanying the spec is a control drawing. This is specific for the Explosion Proof products from the LP35 family and consist of Installation Requirements, Special Conditions of Operation and a Certificate of Conformity. In these documents, the LP series models are referred to as HH_X and AH_X. Despite the difference in nomenclature, these are the same product specified under the LP35 nomenclature. Both the LP35 and the HH_X or AH_X model numbers will appear on the label of the finished product. ACCESSORIES The following accessories are included with your LP series encoder as defined by your part number selection. Bore Reduction Sleeve 9418/EE6 = 3/4 in. bore 9418/EE8 = 1 in. bore 9418.E20 = 20 mm Integrated Coupling Kit (includes flex, hub and set screws) M9410/010-E3 = 3/8 in. M9410/010-E4 = 1/2 in. M9410/010-E5 = 5/8 in. M9410/010-E6 = 3/4 in. M9410/010-11 = 10 mm M9410/010-12 = 12 mm M9410/010-14 = 14 mm M9410/010-20 = 20 mm Flexible Couplings Bellows Type 9404/S/12-12 = for use with a 12mm shaft Triple Beam Type 39074-12-12 = for use with a 3/8” shaft Ball End Tether M9230-03/XXX (XXX=Center-to-center nominal distance in mm) GENERAL NOTES (A) For detailed installation instructions and recommend screw torques refer to the User’s Manual AGENCY APPROVALS & CERTIFICATIONS These commodities, technology or software if exported from the United States must be in accordance with the Bureau of Industry and Security, Export Administration regulations. Diversion contrary to U.S. Law is prohibited. Class I, Group C & D CENELEC II 2 G Ex db IIB T4 Gb DEMKO 16 ATEX 1691X IECEx UL 16.0064X Ex db IIB T4 Gb 2004/108/CE

Specification sheet AH_X/HH_X - P/N 2000/040 Rev. B www.beisensors.com LP Series Explosion-proof and Flameproof Incremental Encoder SPECIAL CONDITIONS FOR SAFE USE: The gaps of the different flame paths are less than the values specified in the tables of the IEC 60079-1 standard. The width of the different flameproof joints are superior to these specified in tables of IEC 60079-1 standard. See Document 08329-001 for construction details. ASSEMBLY CAUTION/WARNING: Keep terminal cover closed and cable gland secured while in presence of hazardous atmosphere. Open all circuits to this product prior to removal of terminal block cover. Electrical installation shall use standard EN/IEC 60079-14 and/or NEC Class 2 circuit specifications. UL certified installations require the use of a sealing fitting certified to 60079-0 Ex d IIB within 18 in. (46 cm) of the encoder. Terminal block covers are marked near the threaded hole with the basic thread size to aid with selection of fittings or glands. Conductor insulation must be rated for at least 105°C ambient temperature. External case ground connection is provided by means of a screw and ring type terminal which accepts up to 10 AWG (5.26 mm2) size conductor. The customer shall use our products according to our specifications and to the manners of the profession. BEI Sensors will not be responsible for any defect resulting from improper installation or from operating outside of the specification limits of the product. Malfunctions caused by excessive shocks, bad electric supply, under or over voltage, the environmental conditions outside of the design specifications, are not covered by warranty. The encoder doesn’t require any maintenance. There are no user serviceable parts inside. Any defective encoder shall be returned to the nearest BEI Sensors facility for evaluation and repair/replacement. A high integrity case ground connection must be made at or near the encoder installation location. See LP35 User Manual (Doc. No. XXX) for installation details and Specification Document (no. 2000/008 or 2000/009) for product details not otherwise indicated on this document. EU Declaration of Conformity 1. We, BEI Sensors, certify that Models HH_X and AH_X all resolutions, channel and output type options are explosion proof and flame proof as noted on the UL, IECEXand DEMKO certificates cited below. 2. With the following marking:II 2 G Ex db IIB T4 Gb 3. Designed and manufacturedto complywith these directives: ATEX : 2014/34/EU and CEM : 2014/30/EU 4. Complies with these standards : ATEX: EN IEC 60079-0:2018, EN60079-1:2014, EN60079-31:2014 IECEx: IEC 60079-0:2017, IEC60079-1:2014, IEC60079-31:2013 A comparative study of the standards EN 60079-0 (2012+A11 2013 and 2018), EN 60079-1(2014) and EN 60079-31( 2014) shows that the product is not concerned by the substantial modifications, 5. As detailedin EC type examination certificates: DEMKO16 ATEX 1691X rev.0 andIECEx UL 16.0064X Issue 0 Product Quality AssuranceNotification:LCIE 03 ATEX Q8060 Product Quality AssuranceReport: FR/LCI/QAR08 0002 6. EMC: The followingstandards were also investigatedfor this certification:NFC 23-520, NFC 23-539, EN 50081-1, EN 55022 classe B, EN 55014, EN 61000-6-2, CEI 61000-4-2, CEI 61000-4-3, CEI61000-4-4, CEI 61000-4-5, CEI 61000-4-6, CEI 61000-4-8, CEI61000-4-11 7. The notified organization responsible for the follow-up of theATEX directiveis (Assessed by): LCIE, B.P.8, F92260 Fontenay-aux-Roses - Identification number: 0081 8. The companyin charge of certificationCEM is: LCIE BUREAU VERITAS,Aire de la Thur 68840 Pulversheim UL Declaration of Conformity Part number Model HH_X and AH_X model for use in Class I, Group C & D UL 1203 Explosion-Proof and Dust-Ignition-Proof Electrical Equipment for Use in Hazardous (Classified) Locations C22.2 No. 30-M1986 - Explosion-Proof Enclosures for Use in Class I Hazardous Locations UL Certificate No. 201609XX-E78446 UL Report No. E78446-XXX Issue date: The notified organization responsible for the follow-up inspections for this UL listingis (Assessed by): UL International (France) SA Espace Technologique de Saint-Aubin, Immeuble Explorer Route de l’Orme des Merisiers – F-91190 SAINT AUBIN: Identification number: 675