1www.power-one.com Edition 4/04.2001
- Rugged electrical and mechanical design
- Outputs individually controlled with excellent dynamic properties
- Operating ambient temperature range –40...71°C with convection cooling M Series 50 Watt AC-DC Converters Input voltage range 85...264 V AC 1, 2 or 3 isolated outputs up to 48 V DC 4 kV AC I/O electric strength test voltage Selection chart Output 1 Output 2 Output 3 Input Type Options U o nom Io nom U o nom Io nom U o nom Io nom voltage [V DC] [A] [V DC] [A] [V DC] [A] U i [V AC] 12 2 12 2 - - 85...264 LM 2320-7 -9, E, P, D, A, H, F 12 2 12 2 - - 85...264 LMZ 2320-7 -9, E, P, D, A, H, F LGA
2www.power-one.com Edition 4/04.2001 Cassette Style M Series Input Input voltage continuous range 85...264 V AC Input frequency 47...65(440) Hz Inrush current limitation by thermistor Output Efficiency U i nom, Io nom up to 81% Output voltage setting accuracyU i nom, Io nom ±0.6% U o nom Output voltage switching noise IEC/EN 61204, total typ. 50 mV pp Minimum load not required 0 A Current limitation main output rectangular U/I characteristic typ. 110% Io nom Current limitation aux. output(s) rectangular U/I characteristic typ. 120% Io nom Operation in parallel by current limitation, only main outputs Hold-up time U i = 230 V AC, Io nom typ. 90 ms Protection Input fuse built-in T 2.5 A, 250 V AC Input undervoltage lockout typ. 80% U i min Input overvoltage lockout typ. 110% U i max Input transient protection varistor or suppressor diode Output no-load, overload and short circuit proof Output overvoltage suppressor diode in each output typ. 150% U o nom Overtemperature switch-off with auto restart TC typ. 100°C Control Output voltage adjustment single output types 0...110% U o1 nom Inhibit TTL input, output(s) disabled if open circuit Status indication LEDs: OK, inhibit, overload Safety Approvals EN 60950, UL 1950, CSA C22.2 No. 950 Class of equipment LM class I LMZ class II Protection degree units without options IP 40 Electric strength test voltage class I, I/case 2 kV AC class I, I/O 4 kV AC class II (LMZ), I/O and I/case 4 kV AC O/case 1 kV AC O/O 0.2 kV AC
3www.power-one.com Edition 4/04.2001 EMC Electrostatic discharge IEC/EN 61000-4-2, level 4 (8/15 kV) criterion A Electromagnetic field IEC/EN 61000-4-3, level x (20 V/m) criterion A/B Electr. fast transients/bursts IEC/EN 61000-4-4, input, level 3/4 (2/4 kV) criterion A/B Surge IEC/EN 61000-4-5, input, level 3/4 (2/4 kV) criterion A Conducted disturbances IEC/EN 61000-4-6, level 3 (10 V) criterion B Electromagnetic emissions CISPR 22/EN 55022, class I, conducted class B Environmental Operating ambient temperatureU i nom, Io nom, convection cooled –25...71°C Operating case temperature TC U i nom, Io nom –25...95°C Storage temperature non operational –40...100°C Damp heat IEC/EN 60068-2-3, 93%, 40 °C 56 days Shock IEC/EN 60068-2-27, 6 ms 100 g n Bump IEC/EN 60068-2-29, 6 ms 40 g n Random vibration IEC/EN 60068-2-64, 20 … 500 Hz 4.9 g n rms MTBF MIL-HDBK-217E, G B, 40°C, single output types 320'000 h Options Extended temperature range –40...71°C, ambient, operating -9 Electronic inrush current limitation E Output voltage adjustment 95...105% U o nom, excludes feature R and vice versa P Input and/or output undervoltage monitoring, excludes option V D0...D9 Input and/or output undervoltage monitoring (VME), excludes option D V1...V3 Test sockets for check of output voltage A Enhanced electric strength test 2 kV AC H Fuse not user accessible F Pin allocation Pin Electrical determination LM 1000 LMZ 1000 LM 2000 LMZ 2000 LM 3000 LMZ 3000
2 Inhibit control input iiiiii
5 Data safe or ACFAIL D or V D or V D or V D or V D or V D or V
8 Output voltage (positive) Vo1+ Vo1+ Vo3+ Vo3+
11 Output voltage (negative) Vo1 – Vo1– Vo3– Vo3–
14 Control input + R R
17 Control input – GG
14 Output voltage (positive) Vo2+ Vo2+ Vo2+ Vo2+
17 Output voltage (negative) Vo2 – Vo2– Vo2– Vo2–
20 Output voltage (positive) Vo1+ Vo1+ Vo1+ Vo1+ Vo1+ Vo1+
23 Output voltage (negative) Vo1 – Vo1– Vo1– Vo1– Vo1– Vo1–
26 Protective earth
29 AC input voltage N N N N N N
32 AC input voltage P P P P P P
M Series 50 Watt AC-DC Converters
4www.power-one.com Edition 4/04.2001 Cassette Style M Series Mechanical data Tolerances ±0.3 mm (0.012") unless otherwise indicated. European Projection Accessories Front panels 19” (Schroff/Intermas) Mating H11 connectors with screw, solder, fast-on or press-fit terminals Connector retention facilities and code key system for connector coding Flexible PCB for connecting the converter via an H11 connector, if mounted on a PCB Chassis or wall mounting plates for frontal access Universal mounting brackets for chassis or DIN-rail mounting 111.2 (3U) (4.38") 168.5 (6.63") 127 (5") 173.7 (6.84") 20 (0.79") 6TE 2 5 8 11 14 17 20 23 26 29 32 38.7 (1.52") Measuring point for case temperature TC M 3; depth = 4 mm (chassis mount) 2TE IoL Test sockets (option A) Potentiometer(s) (option P) OK Inhibit i Potentiometer (option D) or potentiometer (option V) S09012 103 22 (0.87")