General-Purpose Audible Indicators
- Rugged, cost-effective and easy to install
- Compact devices are self-contained, no controller needed
- Immune to EMI and RFI interference
- Choose IEC IP50 or Sealed IEC IP67 model, black or light gray housing
- 12 V dc to 30 V dc, or 24 V ac operation Models Standard Audible Models 1 Connection2 Inputs TL50AQ Integral 4-pin M12/Euro-style quick disconnect Bimodal (NPN or PNP) Sealed Audible Models 1 Connection 2 Inputs Continuous Pulsed at 1.6 Hz Staccato TL50ALSQ TL50ALS3Q TL50ALS4Q Integral 4-pin M12/Euro-style quick disconnect Bimodal (NPN or PNP) Omni-Directional Sealed Audible Models 1 Connection 2 Inputs Continuous Pulsed at 1.6 Hz Staccato TL50AOSQ TL50AOS3Q TL50AOS4Q Integral 4-pin M12/Euro-style quick disconnect Bimodal (NPN or PNP) Omni-Directional Sealed Audible Models with Intensity Adjustment 1 Connection 2 Inputs Continuous Pulsed at 1.6 Hz Staccato TL50AOSIQ TL50AOS3IQ TL50AOS4IQ Integral 4-pin M12/Euro-style quick disconnect Bimodal (NPN or PNP) Wiring Diagrams PNP Input A 12-30V dc or 24V ac No Connection No Connection NPN Input A 12-30V dc or 24V ac No Connection No Connection Key 1 = Brown 2 = White 3 = Blue 4 = Black 1 Models with black housing are listed. For gray housing, add the suffix "C" at the end of the cabled model number or before the "Q" in quick disconnect model numbers. For example, TL50AC or TL50ACQ. 2 Integral quick disconnect models are listed.
- To order the 150 mm (6 in) PVC cable model with a M12/Euro-style quick disconnect, replace the suffix "Q" with "QP" in the model number. For example, TL50AQP.
- To order the 2 m (6.5 ft) PVC cable model, omit the suffix "Q" in the model number. For example, TL50A.
- Models with a quick disconnect require a mating cordset. TL50A Audible Indicators Original Document 155019 Rev. J
7 May 2019
Specifications Supply Voltage and Current
12 V dc to 30 V dc; or 24 V ac (± 3 V ac) at 50 Hz to 60 Hz
Standard Audible Alarm: 25 mA maximum current Sealed Audible Alarm: 35 mA maximum current Omni-Directional Sealed Audible Alarm: 45 mA maximum current Audible Alarm Standard Audible Alarm: 2.7 kHz ± 500 Hz oscillation frequency; maximum intensity 92 dB at 1 m (3.3 ft) (typical) Sealed Audible Alarm: 2.9 kHz ± 250 Hz oscillation frequency; maximum intensity 94 dB at 1m (3.3 ft) (typical) Omni-Directional Sealed Audible Alarm: 2.1 kHz ± 250 Hz oscillation frequency; maximum intensity 99 dB at 1 m (3.3 ft) (typical) Audible Adjustment Standard Audible Alarm: Unscrew the cover (up to 1.5 turns maximum) to adjust the audible intensity (do not exceed 1.5 turns or the cover may detach during operation). For maximum intensity, rotate the center plug 180° counterclockwise to remove it. Sealed Audible Alarm and Omni-Directional Sealed Audible Alarm with Intensity Adjustment: Rotate the front cover until the desired intensity is reached. Typical Reduction in Sound Intensity with Audible Adjustment (maximum to minimum):
- Standard Audible Alarm: 30 dB
- Sealed Audible Alarm: 20 dB
- Omni-Directional Sealed Audible Alarm: 12 dB Connections Integral 4-pin M12/Euro-style quick disconnect, 150 mm (6 in) PVC cable with a M12/ Euro-style quick disconnect, or 2 m (6.5 ft) integral PVC cable, depending on model Models with a quick disconnect require a mating cordset Vibration and Mechanical Shock Meets IEC 60068-2-6 requirements (Vibration: 10 Hz to 55 Hz, 1.0 mm amplitude, 5 minutes sweep, 30 minutes dwell) Meets IEC 60068-2-27 requirements (Shock: 30G 11 ms duration, half sine wave) Operating Conditions 95% at +50 °C maximum relative humidity (non-condensing) Environmental Rating UL Type 4X Indoor and UL Type 13 Standard models: IEC IP50 Sealed models: IEC IP67 Required Overcurrent Protection WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. Supply Wiring (AWG) Required Overcurrent Protection (Amps) 20 5.0 22 3.0 24 2.0 26 1.0 28 0.8 30 0.5 Certifications Dimensions Standard Audible Models 26.9 [1.06] 1/2-14 NPSM [1.77] ø50 [1.97] 111 [4.37] Sealed Audible Models [0.75] M30 X 1.5-6 g 93.4 [3.68] ø45 [1.77] 1/2-14 NPSM ø50 [1.97] Omni-Directional Models ø50 [1.97] 107.5 [4.23] 19.0 [0.75] M30 X 1.5 M12 X 1-6 g 45.0 [1.77] 1/2-14 NPSM All measurements are listed in millimeters [inches], unless noted otherwise. TL50A Audible Indicators 2 www.bannerengineering.com - Tel: + 1 888 373 6767 P/N 155019 Rev. J
4-Pin Threaded M12/Euro-Style Cordsets—Single Ended Model Length Style Dimensions Pinout (Female) MQDC-406 1.83 m (6 ft) Straight 44 Typ. ø 14.5 M12 x 1 1 = Brown 2 = White 3 = Blue 4 = Black MQDC-415 4.57 m (15 ft) MQDC-430 9.14 m (30 ft) MQDC-450 15.2 m (50 ft) MQDC-406RA 1.83 m (6 ft) Right-Angle 32 Typ. [1.26"] 30 Typ. [1.18"] ø 14.5 [0.57"] M12 x 1 MQDC-415RA 4.57 m (15 ft) MQDC-430RA 9.14 m (30 ft) MQDC-450RA 15.2 m (50 ft) Mounting Brackets All measurements are listed in millimeters [inches], unless noted otherwise. SMB30A
- Right-angle bracket with curved slot for versatile orientation
- Clearance for M6 (¼ in) hardware
- Mounting hole for 30 mm sensor
- 12-ga. stainless steel A B C Hole center spacing: A to B=40 Hole size: A=ø 6.3, B= 27.1 x 6.3, C=ø 30.5 SMB30FA
- Swivel bracket with tilt and pan movement for precise adjustment
- Mounting hole for 30 mm sensor
- 12-ga. 304 stainless steel
- Easy sensor mounting to extrude rail T-slot
- Metric and inch size bolt available A B 68.936.3 83.2 Bolt thread: SMB30FA, A= 3/8 - 16 x 2 in; SMB30FAM10, A= M10 - 1.5 x 50 Hole size: B= ø 30.1 SMB30MM
- 12-ga. stainless steel bracket with curved mounting slots for versatile orientation
- Clearance for M6 (¼ in) hardware
- Mounting hole for 30 mm sensor A B C Hole center spacing: A = 51, A to B = 25.4 Hole size: A = 42.6 x 7, B = ø 6.4, C = ø 30.1 SMBAMS30P
- Flat SMBAMS series bracket
- 30 mm hole for mounting sensors
- Articulation slots for 90°+ rotation
- 12-ga. 300 series stainless steel 93 A C B Hole center spacing: A=26.0, A to B=13.0 Hole size: A=26.8 x 7.0, B=ø 6.5, C=ø 31.0 SMBAMS30RA
- Right-angle SMBAMS series bracket
- 30 mm hole for mounting sensors
- Articulation slots for 90°+ rotation
- 12-ga. (2.6 mm) cold-rolled steel A C B Hole center spacing: A=26.0, A to B=13.0 Hole size: A=26.8 x 7.0, B=ø 6.5, C=ø 31.0 SMB30SC
- Swivel bracket with 30 mm mounting hole for sensor
- Black reinforced thermoplastic polyester
- Stainless steel mounting and swivel locking hardware included B A Hole center spacing: A=ø 50.8 Hole size: A=ø 7.0, B=ø 30.0 TL50A Audible Indicators P/N 155019 Rev. J www.bannerengineering.com - Tel: + 1 888 373 6767 3
- Direct mounting of stand-off pipe, with common bracket type
- Zinc-plated steel
- 1/2-14 NPSM nut
- Mounting distance from the wall to the center of the 1/2-14 NPSM nut is 35 mm Hole center spacing: 20.0 38.25 2X Ø9 1/2 - 14 NPSM NUT LMBE12RA45
- Direct mounting of stand-off pipe, with common bracket type
- Zinc-plated steel
- 1/2-14 NPSM nut
- Mounting distance from the wall to the center of the 1/2-14 NPSM nut is 45 mm Hole center spacing: 35.0 38.25 2X Ø11 1/2 - 14 NPSM NUT Pipe Mounting Flange Pipe Mounting Flange Model Features Construction SA-F12
- Elevated-use stand-off pipes (½ in, NPSM/ DN15)
- M5 mounting hardware and nitrile gasket included Die-cast zinc base with black paint ø28 ø70 1/2-14 NPSM 4x ø5.5 SA-F12-3
- Elevated-use stand-off pipes (½ in, NPSM/ DN15)
- M4 mounting hardware and nitrile blend gasket included Black Polycarbonate 8.77 ø60 ø40 2 x 120°1/2-14 NPSM LMB Sealed Right-Angle Bracket Model Description Construction LMB30RA Direct-Mount Models: Bracket kit with base, 30 mm adapter, set screw, fasteners, O-rings, and gaskets. Black polycarbonate LMB30RAC Gray polycarbonate LMBE12RA Pipe-Mount Models: Bracket kit with base, ½-14 pipe adapter, set screw, fasteners, O-rings, and gaskets. For use with stand-off pipe (listed and sold separately). Black polycarbonate LMBE12RAC Gray polycarbonate Elevated Mount System Model Features Components SA-M30TE12 - Black Acetal • Streamlined black acetal or white UHMW stand-off pipe adapter/cover
- Connects between 30 mm light base and ½ in. NPSM/DN15 pipe
- Mounting hardware included SA-M30TE12C - White UHMW Polished 304 Stainless Steel Black Anodized Aluminum Clear Anodized Aluminum
- Elevated-use stand-off pipe (½ in. NPSM/DN15)
- Polished 304 stainless steel, black anodized aluminum, or clear anodized aluminum surface
- ½ in. NPT thread at both ends
- Compatible with most industrial environments SOP-E12-150SS 150 mm (6 in) long SOP-E12-150A 150 mm (6 in) long SOP-E12-150AC 150 mm (6 in) long SOP-E12-300SS 300 mm (12 in) long SOP-E12-300A 300 mm (12 in) long SOP-E12-300AC 300 mm (12 in) long SOP-E12-900SS 900 mm (36 in) long SOP-E12-900A 900 mm (36 in) long SOP-E12-900AC 900 mm (36 in) long SA-E12M30 - Black Acetal • Streamlined black acetal or white UHMW mounting base adapter/cover
- Connects between ½ in. NPSM/DN15 pipe and 30 mm (1-3/16 in) drilled hole
- Mounting hardware included SA-E12M30C - White UHMW TL50A Audible Indicators 4 www.bannerengineering.com - Tel: + 1 888 373 6767 P/N 155019 Rev. J
Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. For patent information, see www.bannerengineering.com/patents. TL50A Audible Indicators © Banner Engineering Corp. All rights reserved