LM181E1 PHILIPS | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 24

Technical content

Datasheet sections

  • 00751 Helsinki, Finland

Ver 0.3 July 5, 2000 Page 1/24 SPECIFICATION FOR APPROVAL ( ♦♦ ) Preliminary Specification ( ) Final Specification Title 18.1” SXGA TFT LCD BUYER SUPPLIER LG.Philips LCD Co., Ltd. MODEL *MODEL LM181E1 SUFFIX H2MN *When you obtain standard approval, please use the above model name without suffix. SIGNATURE DATE APPROVED BY S.H. Kang / G.Manager DATE REVIEWED BY B.G. Kim / Manager G.T. Kim / Manager PREPARED BY S.Y. Ahn / Engineer C.G. Kim / Engineer Please return 1 copy for your confirmation with your signature and comments. Product Engineering Dept. LG.Philips LCD Co., Ltd.

Ver 0.3 July 5, 2000 Page 3/24 RECORDS OF REVISIONS Version No Date Page

DESCRIPTION

0.1 0.11 0.2 0.3 Mar. 31, 2000 Apr. 20, 2000 May 17, 2000 July 5, 2000 p16 p13 p13 p14 Preliminary Change the mechanical characteristics. Changed the B/L wire length : 80mm 140mm Fill the Color Coordinates. Correct the misprint. Fill the gray scale. Alpha Point Ltd. P.O. Box 41

00751 Helsinki, Finland

http://www.alpha.fi Tel.: +358-9-34 64 34 1 Fax: +358-9-34 64 34 2

Ver 0.3 July 5, 2000 Page 4/24 1. General Description The LM181E1-H2MN is a Color Active Matrix Liquid Crystal Display with an integral Cold Cathode Fluorescent Lamp(CCFL) back light system. The matrix employs a-Si Thin Film Transistor as the active element. It is a transmissive type display operating in the normally black mode. This TFT-LCD has a 18.1 inch diagonally measured active display area with SXGA resolution(1024 vertical by 1280 horizontal pixel array). Each pixel is divided into Red, Green and Blue sub-pixels or dots which are arranged in vertical stripes. Gray scale or the brightness of the sub-pixel color is determined with a 8-bit gray scale signal for each dot, thus, presenting a palette of more than 16,777,216 colors. The LM181E1-H2MN has been designed to apply the interface method that enables low power, high speed low EMI. FPD Link must be used as a LVDS(Low Voltage Differential Signaling) chip. The LM181E1-H2MN is intended to support applications where thin thickness, wide viewing angle, low power are critical factors and graphic displays are important. In combination with the vertical arrangement of the sub-pixels, the LM181E1-H2MN characteristics provide an excellent flat panel display for office automation products such as monitors. CN1 (21pin) LVDS pair #1 LVDS pair #2 LVDS LVDS CN2 (5pin) Timing Controller Power Circuit Block +12V IVAA RGB(F) RGB(S) CLK,DTMG HSYC,VSYNC Gate Driver circuit Source Driver Circuit TFT-LCD Panel (1280 x RGB x 1024 pixels) S1280 G1024 Backlight Assembly(4CCFL) CN3/4 CN5/6 RGB CLK General Features The following are general feature of the model LM181E1-H2MN LCD; Active screen size 18.1 inches(45.97cm) diagonal Outline dimensions Pixel pitch 0.2805 mm × 0.2805 mm Pixel format 1280 horiz. By 1024 vert. Pixels RGB stripe arrangement Color depth 8-bit, 16,777,216 colors Luminance,White 200 cd/m2 (Typ.) Power Consumption Total 29.16Watt,Typ.(6.6Watt @IVAA,22.56Watt@200cd/m2 [Lamp]) Weight 2835 (Max.) Display operating mode Transmissive mode, normally black Surface treatments Hard coating(3H), Anti-glare treatment of the front polarizer Alpha Point Ltd. P.O. Box 41 http://www.alpha.fi Tel.: +358-9-34 64 34 1 Fax: +358-9-34 64 34 2

The following are maximum values which, if exceeded, may cause faulty operation or damage to the unit. Table 1. ABSOLUTE MAXIMUM RATINGS Note: 1. Temperature at 5mm above display center of LCD Module. Ta 50 : Absolute Humidity shall be less than Ta = 40 90%RH . These shall be no dew condensation.

  1. Humidity Min. 5%RH, Max. 90%RH
  1. Electrical Specifications

an inverter. The inverter is an external unit to the LCD. Table 2. ELECTRICAL CHARACTERISTICS Note)The design of the inverter must have specifications for the lamp in LCD Assembly. so as not to produce too much leakage current from high-voltage output of the inverter. should be operated in the same condition as installed in your instrument. Notes:1. The current draw and power consumption specified is for 12.0 Vdc at 25and fv at 60Hz.

  1. The variance of the voltage is ±10%.
  2. The output voltage at the transformer in the inverter must be high considering to the loss of the

ballast capacitor in the inverter.

  1. The output of the inverter must have symmetrical(negative and positive) voltage waveform and

inverter which has unsymmetrical voltage and unsymmetrical current and spike wave. the horizontal synchronous frequency and from its harmonics in order to prevent interference.

  1. The lamp power consumption shown above does not include loss of external inverter.
  2. Let’s define the brightness of the lamp after being lighted for 5 minutes as 100%.

Ts is the time required for the brightness of the center of the lamp to be not less than 95%.

  1. The life time is determined as the time at which brightness of lamp is 50% compare to that of

initial value at the typical lamp current on condition of continuous operating at 25 ±2.

Ver 0.3 July 5, 2000 Page 7/24 3-2. Interface Connections Interface chip must be used LVDS, part No. DS90CF383MTD(Transmitter), DS90CF384MTD(Receiver) made by National Semiconductor. Or used the compatible interface chips(TI : SN75LVDS83, Thine). This LCD employs six interface connections. A 21-pin connector is used for the module electronics interface. A 5-pin connector is used for the module power(+12V). Four 2-pin connectors are used for the integral backlight system. The electronics interface connector is a model GT121-21P-TD manufactured by LGC. The pin configuration for the connector is shown in the table 3. Table 3. MODULE CONNECTOR PIN CONFIGURATION (LVDS) Plus Signal of Odd Channel 3 (LVDS) Minus Signal of Odd Channel 3 (LVDS) Plus Signal of Odd Clock Channel (LVDS) Minus Signal of Odd Clock Channel (LVDS) Plus Signal of Odd Channel 2 (LVDS) Minus Signal of Odd Channel 2 (LVDS) Plus Signal of Odd Channel 1 (LVDS) Minus Signal of Odd Channel 1 (LVDS) Plus Signal of Odd Channel 0 (LVDS) Minus Signal of Odd Channel 0 (LVDS) Plus Signal of Even Channel 3 (LVDS) Minus Signal of Even Channel 3 (LVDS) Plus Signal of Even Clock Channel (LVDS) Minus Signal of Even Clock Channel (LVDS) Plus Signal of Even Channel 2 (LVDS) Minus Signal of Even Channel 2 (LVDS) Plus Signal of Even Channel 1 (LVDS) Minus Signal of Even Channel 1 (LVDS) Plus Signal of Even Channel 0 (LVDS) Minus Signal of Even Channel 0 (LVDS) Not Connect Bottom Side Top Side ¡ ã Back side of LCD Module Pin 1 Pin 5 Pin 1 Pin 21 CN2 Power Connector CN1 Module Connector First Data Second Data Alpha Point Ltd. P.O. Box 41 http://www.alpha.fi Tel.: +358-9-34 64 34 1 Fax: +358-9-34 64 34 2

Ver 0.3 July 5, 2000 Page 8/24 The module power connector is a model B5B-ZR-SM3-TF manufactured by JST. The pin configuration for the connector is shown in the table 4. Table 4. POWER CONNECTOR PIN CONFIGURATION Supply voltage for LCD module Supply voltage for LCD module Notes: 1. All GND(ground) pins should be connected together and to Vss which should also be connected to the LCD’s metal frame. 2. All IVAA(power input) pins should be connected together. The backlight interface connector is a model BHSR-02VS-1, manufactured by JST. The mating connector part number is SM02B-BHSS-1 or equivalent. The pin configuration for the connector is shown in the table 5. Table 5. BACKLIGHT CONNECTOR PIN CONFIGURATION Notes: 1. The input power terminal is colored pink or white. Ground pin color is white or black. 2. The lamp ground should be common with GND. Pink Black White White CN3,5 CN4,6 Alpha Point Ltd. P.O. Box 41 http://www.alpha.fi Tel.: +358-9-34 64 34 1 Fax: +358-9-34 64 34 2

should be satisfied with the following specifications for it’s proper operation. Table 6. Timing Table Note 1. Two pixel data are sampled at the same time.

Ver 0.3 July 5, 2000 Page 10/24 3-4. Signal Timing Wave Form DCLK Hsync, Vsync, DE, DATA tCLK 0.5VCC Second DATA VALID DATA INVALID INVALID DE(Data Enable) HSync DE VSync DE 0.7Vcc 0.3Vcc tWH tHP tHFP tHBP tVP tWV tVBP tVFP VALID DATA INVALID INVALID First DATA pixel pixel 1,0 3,0 pixel pixel 0,0 2,0 Alpha Point Ltd. P.O. Box 41 http://www.alpha.fi Tel.: +358-9-34 64 34 1 Fax: +358-9-34 64 34 2

Table 7. COLOR DATA REFERENCE

Ver 0.3 July 5, 2000 Page 12/24 3-6. Power Sequences Interface Signal, Vi (Signal of Transmitter) Power Supply For LCD Power For Lamp Lamp “On” Lamp “Off” Lamp “Off” Valid Data 90% 90% 10% 10% Values Parameter Min. Typ. Max. Units 100 100 0.01 300 300 ms ms ms ms ms ms s Notes: 1. Please avoid floating state of interface signal at invalid period. 2. When the interface signal is invalid, be sure to pull down the power supply for LCD VCC to 0V. Invalid input with IVAA for a long time, cause permanent damage to LCD panel. 3. Lamp power must be turn on after power supply for LCD and interface signal are valid. Alpha Point Ltd. P.O. Box 41 http://www.alpha.fi Tel.: +358-9-34 64 34 1 Fax: +358-9-34 64 34 2

the LCD surface at a viewing angle of Φ and θ equal to 0°. Appendix A -1 presents additional information concerning the measurement equipment and method.. Table 8. OPTICAL CHARACTERISTICS

  1. Surface luminance is the center point across the LCD surface 50cm from the surface with all
  2. The variation in surface Luminance, WHITE is determined by measuring LON at each test position

points luminance. For more information see Appendix A - 2.

  1. Response time is the time required for the display to transition from black to white (Rise Time,

TrR) and from white to black (Decay Time, TrD). For additional information see Appendix A - 3.

Ver 0.3 July 5, 2000 Page 14/24 5. Viewing angle is the angle at which the contrast ratio is greater than 10. The angles are determined for the horizontal or x axis and the vertical or y axis with respect to the z axis which is normal to the LCD surface. For more information see Appendix A - 4 6.Gray scale specification is as following. Gray Level Luminance (%)(typ) 0.35 L31 0.75 L63 2.8 L95 9.0 L127 18.7 L159 32.1 L191 52.3 L223 74.6 L255 100 Alpha Point Ltd. P.O. Box 41 http://www.alpha.fi Tel.: +358-9-34 64 34 1 Fax: +358-9-34 64 34 2

Ver 0.3 July 5, 2000 Page 15/24 5. Mechanical Characteristics The chart below provides general mechanical characteristics for the model LM181E1-H2MN LCD. In addition, the figure below is a detailed mechanical drawing of the LCD. Note that dimensions are given for reference purposes only. Parameters Value unit Notes Outside dimensions Horizontal Vertical Depth 412.5 333.0 22.5 mm Bezel area Horizontal Vertical 363.5 292.0 mm Active Display area Horizontal Vertical 359.040 287.232 mm Weight 2835(max) gram Surface Treatment Hard coating 3H. Anti-glare treatment of the front polarizer Alpha Point Ltd. P.O. Box 41 http://www.alpha.fi Tel.: +358-9-34 64 34 1 Fax: +358-9-34 64 34 2

Ver 0.3 July 5, 2000 Page 16/24 < FRONT VIEW > Alpha Point Ltd. P.O. Box 41 http://www.alpha.fi Tel.: +358-9-34 64 34 1 Fax: +358-9-34 64 34 2

Ver 0.3 July 5, 2000 Page 17/24 < REAR VIEW > Alpha Point Ltd. P.O. Box 41 http://www.alpha.fi Tel.: +358-9-34 64 34 1 Fax: +358-9-34 64 34 2

Ver 0.3 July 5, 2000 Page 18/24 6. Reliability - Environment test condition No. Test ITEM Conditions High temperature storage test Ta = 60 240h Low temperature storage test Ta = -10 240h High temperature operation test Ta = 50 50%RH 240h Low temperature operation test Ta = 0 240h Humidity Condition operation 20%RH ~ 80%RH Humidity Condition storage 5%RH ~ 90%RH Vibration test (non-operating) TBD Shock test (non-operating) TBD Altitude storage/shipment 0 - 40,000 feet (12192m) {Result Evaluation Criteria} There should be no change which might affect the practical display function when the display quality test is conducted under normal operating condition. Alpha Point Ltd. P.O. Box 41 http://www.alpha.fi Tel.: +358-9-34 64 34 1 Fax: +358-9-34 64 34 2

Ver 0.3 July 5, 2000 Page 19/24 7. International Standards 7-1. Safety a) UL 1950 Third Edition, Underwriters Laboratories, Inc. Jan. 28, 1995. Standard for Safety of Information Technology Equipment Including Electrical Business Equipment. b) CAN/CSA C22.2 No. 950-95 Third Edition, Canadian Standards Association, Jan. 28, 1995. Standard for Safety of Information Technology Equipment Including Electrical Business Equipment. c) EN 60950 : 1992 + A1 : 1993 + A2 : 1993 + A3 : 1995 + A4 : 1997 + A11 : 1997 IEC 950 : 1991 + A1 : 1992 + A2 : 1993 + A3 : 1995 + A4 : 1996 European Committee for Electrotechnical Standardization (CENELEC) EUROPEAN STANDARD for Safety of Information Technology Equipment Including Electrical Business Equipment. 7-2. EMC a) ANSI C63.4 “Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9kHz to 40GHz.” American National Standards Institute(ANSI),1992. b) C.I.S.P.R “Limits and Methods of Measurement of Radio Interference Characteristics of Information Technology Equipment.” International Special Committee on Radio Interference (standards apply by CISPR22 callss B) c) EN 55022 “Limits and Methods of Measurement of Radio Interference Characteristics of Information Technology Equipment.” European Committee for Electrotechnical Standardization (CENELEC),1988 Alpha Point Ltd. P.O. Box 41 http://www.alpha.fi Tel.: +358-9-34 64 34 1 Fax: +358-9-34 64 34 2

Ver 0.3 July 5, 2000 Page 20/24 8. Packaging 8-1. Designation of Lot Mark a) Lot Mark A, B ,C : SIZE D : YEAR E : MONTH F,G : PANEL CODE H : ASSEMBLY CODE I,J,K,L,M : SERIAL NO. Note : 1. YEAR YEAR 2000 2001 2002 2003 2004 2005 2006 2007 Mark 2. MONTH MONTH Jan. Feb. Mar. Apr. May Jun. Jul. Aug. Sep. Oct. Nov. Dec. Mark A B C b) Location of Lot Mark Serial NO. is printed on the label. The label is attached to the backside of the LCD module. This is subject to change without prior notice. 8-2. Packing Form a) Package quantity in one box : 5 pcs b) Box Size : 524mm×301mm×444mm K J I H G F E D C B A L M Alpha Point Ltd. P.O. Box 41 http://www.alpha.fi Tel.: +358-9-34 64 34 1 Fax: +358-9-34 64 34 2

Ver 0.3 July 5, 2000 Page 21/24 9.PRECAUTIONS Please pay attention to the followings when you use this TFT/LCD module.

9.1 MOUNTING PRECAUTIONS

(1) You must mount a module user holes arranged in four corners. (2) You should consider the mounting structure so that uneven force (ex. twisted stress) is not applied to the module. And the case on which a module is mounted should have sufficient strength so that external force is not transmitted directly to the module. (3) Please attach the surface with a transparent protective plate in order to protect the polarizer LC cell. Transparent protective plate should have sufficient strength in order to resist external force. (4) You should adopt radiation structure to satisfy the temperature specification. (5) Acetic acid type and chlorine type materials for the cover case are not desirable because the former generates corrosive gas of attacking the polarizer at high temperature and the latter causes circuit break by electro-chemical reaction. (6) Do not touch, push or rub the exposed polarizer with glass, tweezers or anything harder than HB pencil head And Please do not rub with dust clothes with chemical treatment. Do not touch the surface of polarizer for bare hand or greasy cloth. (Some cosmetics are detrimental to the polarizer.) (7) When the surface becomes dusty, please wipe gently with absorbent cotton or other soft materials like chamois soaked with petroleum benzene. Normal-hexane is recommended for cleaning the adhesives used to attach front / rear polarizer. Do not use acetone, toluene and alcohol because they cause chemical damage to the polarizer. (8) Wipe off saliva or water drops as soon as possible. Their long time contact with polarizer causes deformations and color fading. (9) Do not open the case because inside circuits do not have sufficient strength.

9.2 OPERATING PRECAUTIONS

(1) The spike noise causes the malfunction of circuits. It should be lower than following voltage : V = ± 200mV (Over and under shoot voltage). (2) Response time depends on the temperature. (In lower temperature, it becomes longer.) (3) Brightness depends on the temperature. (In lower temperature, it becomes lower.) And in lower temperature, response time (required time that brightness is stable after turned on ) becomes longer. (4) Be careful for condensation at sudden temperature change. Condensation makes damage to polarizer or electrical contacted parts. And after fading condensation, smear or spot will occur. (5) When fixed patterns are displayed for a long time, remnant image is likely to occur. (6) A module has high frequency circuit. If you need to shield the electromagnetic noise, please do co-work together.

9.3 ELECTROSTATIC DISCHARGE CONTROL

Since a module is composed of electronic circuits. It is not strong to electrostatic discharge. Make certain that treatment persons are connected to ground through wrist band etc. And don’t touch I/F pin directly.

9.4 PRECAUTION FOR STRONG LIGHT EXPOSURE

Strong light exposure causes degradation of polarizer and color filter.

9.5 STORAGE

When storing modules as spares for a long time. The following precautions are necessary. (1) Store them in a dark place. Do not expose the module to sunlight or fluorescent light. Keep the temperature between 5 and 35 at normal humidity. (2) The polarizer surface should not come in contact with any other object. It is recommended that they be stored in the container in which they were shipped. Alpha Point Ltd. P.O. Box 41 http://www.alpha.fi Tel.: +358-9-34 64 34 1 Fax: +358-9-34 64 34 2

Ver 0.3 July 5, 2000 Page 22/24

9.6 HANDLING PRECAUTIONS FOR PROTECTION FILM

(1) When the protection film is peeled off, static electricity is generated between the film and polarizer. This should be peeled off slowly and carefully by people who are electrically grounded and with well ion- blown equipment or in such a condition, etc. (2) The protection film is attached to the polarizer with a small amount of adhesive tape. If some stress is applied to rub the protection film against the polarizer during the time you peel off the film, the adhesive tape is apt to remain on the polarizer. Please carefully peel off the protection film without rubbing it against the polarizer. (3) When the module with protection film attached is stored for a long time, sometimes there remains a very small amount of adhesive tape still on the polarizer after the protection film is peeled off. (4) You can remove the adhesive easily. When the adhesive remains on the polarizer surface or its vestige is recognized, please wipe them off with absorbent cotton waste or other soft material like chamois soaked with normal- hexane. Alpha Point Ltd. P.O. Box 41 http://www.alpha.fi Tel.: +358-9-34 64 34 1 Fax: +358-9-34 64 34 2

Ver 0.3 July 5, 2000 Page 23/24 APPENDIX A-1 Optical Characteristic Measurement Equipment and Method A-2 Luminance Measurement <measuring point for luminance variation> <measuring point for surface luminance > A-3 Response Time The response time is defined as the following figure and shall be measured by switching the input signal for “black” and “white”. TrR TrD 100 Optical Response white black black LCD Module Optical Stage(x,y) Field = 1° Prichard PR-880 or equivalent 500mm 640 960 640 320 256 512 512 768 Alpha Point Ltd. P.O. Box 41 http://www.alpha.fi Tel.: +358-9-34 64 34 1 Fax: +358-9-34 64 34 2

Ver 0.3 July 5, 2000 Page 24/24 A-4 Viewing angle <Definition of viewing angle range> φ = 90¡ £ (12:00) yu θ = 0¡ £ z yd θ φ φ = 180¡ £ (9:00) A φ = 0¡ £ (3:00) xr φ = 270¡ £ (6:00) TFT LCD MODULE xl Alpha Point Ltd. P.O. Box 41 http://www.alpha.fi Tel.: +358-9-34 64 34 1 Fax: +358-9-34 64 34 2