AC/DC120WDIN-RailPowerSupply LIF120-10BxxR2Series 2022.08.04-A/6 Page1of5 MORNSUN Guangzhou Science&TechnologyCo.,Ltd.reservesthecopyrightandrightoffinalinterpretation Report RoHS UL61010-1 EN62368-1 UL61010-2-201
FEATURES
Universal85-264VACor120-370VDCInputvoltage AcceptsACorDCinput(dual-useofsameterminal) Operatingambienttemperaturerange:-40℃ to+70℃ Highefficiencyupto94%,highreliability DCOKfunction ActivePFC 150%peakloadoutputfor3seconds DCONoutputstatusindicatorLED Outputshortcircuit,over-current, over-voltage, over-temperatureprotection Operatingaltitudeupto5000m OVCⅡ Indooruse SafetyaccordingtoIEC/UL/BSEN62368 LIF120-10BxxR2 series is Mornsun AC-DC converter series featuring a cost-effective, energy efficient explosion-proof solution for standard DIN-railmounting.Theproductsofferahighlevelofstabilityandimmunitytonoise,compliantwithinternationalIEC62368standardsforEMC and safety specifications meet IEC/EN/UL/BS EN 62368, UL61010. These light weight AC-DC converters also have an extremely compact design for space saving and are ideal for applications such as industrial control equipment, machinery, and all kinds of applications in a harshenvironments. SelectionGuide Certification PartNo. Output Power(W) NominalOutputVoltage andCurrent(Vo/Io) OutputVoltage AdjustableRange(V) Efficiencyat 230VAC(%)Typ. Max.Capacitive Load(µF) UL/EN LIF120-10B12R2 120 12V/10A 11.8-14.0 93.5 80,000 LIF120-10B24R2 24V/5A 23.5-28.0 50,000 LIF120-10B48R2 48V/2.5A 47.0-53.0 30,000 -- LIF120-10B55R2 121 55V/2.2A 52.0-56.0 InputSpecifications Item OperatingConditions Min. Typ. Max. Unit InputVoltageRange Ratedinput(Certifiedvoltage) 100 -- 240 VAC ACinput 85 -- 264 DCinput 120 -- 370 VDC InputFrequency RatedACinput 50 -- 60 Hz ACinput 47 -- 63 InputCurrent RatedInput -- -- 1.5 A 115VAC -- -- 1.5 230VAC -- -- 0.75 InrushCurrent 115VAC Coldstart -- 15 -- 230VAC -- 30 -- LeakageCurrent 240VAC <1mA PowerFactor 115VAC -- 0.98 -- 230VAC -- 0.94 -- Start-upDelayTime 230VAC -- 300 1000 ms HotPlug Unavailable
AC/DC120WDIN-RailPowerSupply LIF120-10BxxR2Series 2022.08.04-A/6 Page2of5 MORNSUN Guangzhou Science&TechnologyCo.,Ltd.reservesthecopyrightandrightoffinalinterpretation OutputSpecifications Item OperatingConditions Min. Typ. Max. Unit OutputVoltageAccuracy Fullloadrange -- ±1 -- %LineRegulation Ratedload -- ±0.5 -- LoadRegulation 0%-100%load -- ±1 -- Ripple&Noise* 20MHzbandwidth (peak-peakvalue) 12V/24V -- -- 100 mV 48V/55V -- -- 200 Stand-byPowerConsumption -- 2 -- W Hold-upTime -- 20 -- ms DCOKSignal Resistiveload 30VDC/1AMax. ShortCircuitProtection Recoverytime<10saftertheshortcircuitdisappear. Hiccupmode,constantcurrentworks1s,turn off10s,continuous,self-recovery Over-currentProtection 230VAC,ratedload Normaltemperature, hightemperature 105%-200%Io,self-recovery Lowtemperature ≥105%fullloadafterderating,self-recovery Over-voltageProtection 12V ≤18V(Hiccup,self-recoveryafterthe abnormalityisremoved) 24V ≤35V(Hiccup,self-recoveryafterthe abnormalityisremoved) 48V ≤60V(Hiccup,self-recoveryafterthe abnormalityisremoved) 55V ≤63V(Hiccup,self-recoveryafterthe abnormalityisremoved) Over-temperatureProtection 230VAC, 70%load Over-temperatureprotectionstart -- 90 -- Over-temperatureprotectionrelease 60 -- -- Note:1.*The“Tipandbarrelmethod”isusedforrippleand noisetest,outputparallel47uFelectrolyticcapacitor and0.1uFceramiccapacitor,pleasereferto EnclosedSwitchingPowerSupplyApplicationNotesforspecificinformation; 2.*DCOKSignal:Whentheoutputvoltageisnormal, therelayis connected.Whenthe outputvoltageisabnormal(<90%Vo),the relayisdisconnected. GeneralSpecifications Item OperatingConditions Min. Typ. Max. Unit IsolationTest Input- Electricstrengthtestfor1min.,leakagecurrent<15mA 1500 -- -- VACInput-output 3000 -- -- Output- 500 -- -- Insulation Resistance Input- At500VDC 50 -- -- MΩInput-output 50 -- -- Output- 50 -- -- OperatingTemperature -40 -- +70 StorageTemperature -40 -- +85 OperatingHumidity Non-condensing -- -- 95 %RH StorageHumidity 20 -- 95 SwitchingFrequency -- 100 -- KHz PowerDerating Operating temperature derating Inputvoltagederating 85VAC-100VAC 0.67 -- -- %/VAC SafetyStandards 12V/24V/48V UL61010-1,UL61010-2-201safetyapproved& EN62368-1(Report) DesignrefertoIEC/UL/BSEN62368-1 55V DesignrefertoIEC/EN/UL/BSEN62368-1, UL61010-1,UL61010-2-201 SafetyClass CLASSI MTBF MIL-HDBK-217F@25℃ >300,000h
AC/DC120WDIN-RailPowerSupply LIF120-10BxxR2Series 2022.08.04-A/6 Page3of5 MORNSUN Guangzhou Science&TechnologyCo.,Ltd.reservesthecopyrightandrightoffinalinterpretation GeneralSpecifications CaseMaterial Metal(AL5052,SPCC,SGCC) Dimensions 110.00x32.00x124.00mm Weight 490g±10%(Typ.) CoolingMethod Freeairconvection EMCSpecifications EMI CE CISPR32/EN55032 CLASSB RE CISPR32/EN55032 CLASSB Harmoniccurrent IEC/EN61000-3-2 CLASSAandCLASSD EMS ESD IEC/EN61000-4-2 Contact±6KV/Air±8KV perf.CriteriaA RS IEC/EN61000-4-3 10V/m perf.CriteriaA EFT IEC/EN61000-4-4 ±4KV perf.CriteriaA Surge IEC/EN61000-4-5 linetoline±2KV/linetoground±4KV perf.CriteriaA CS IEC/EN61000-4-6 10Vr.m.s perf.CriteriaA Voltagedips,shortinterruptions andvoltagevariationsimmunity IEC/EN61000-4-11 0%,70% perf.CriteriaB ProductCharacteristicCurve Note:1.WithanACinputvoltagebetween85-100VACandaDCinputbetween120-140VDC theoutputpowermustbe deratedas perthetemperature deratingcurves; 2.Thisproductissuitableforapplicationsusingnaturalaircooling;forapplicationsinclosedenvironmentpleaseconsultMornsunFAE.
AC/DC120WDIN-RailPowerSupply LIF120-10BxxR2Series 2022.08.04-A/6 Page4of5 MORNSUN Guangzhou Science&TechnologyCo.,Ltd.reservesthecopyrightandrightoffinalinterpretation InstallationDiagram Note:Keepthefollowing installationclearances:20mm ontop, 20mmonthebottom,5mmonthe leftandrightsidesare recommendedwhenthedeviceis loadedpermanentlywithmorethan50% ofthe ratedpower.Increasethisclearanceto15mmincasetheadjacentdevice isaheatsource(e.g.another powersupply). DimensionsandRecommendedLayout
AC/DC120WDIN-RailPowerSupply LIF120-10BxxR2Series 2022.08.04-A/6 Page5of5 MORNSUN Guangzhou Science&TechnologyCo.,Ltd.reservesthecopyrightandrightoffinalinterpretation WARNINGRiskofelectricalshock,fire,personalinjuryordeath: AVERTISSEMENTAVERTISSEMENTRisquedechocélectrique,d’incendie,deblessurescorporellesoudedécès: 1. Donotusethepowersupplywithoutpropergrounding(ProtectiveEarth).Usetheterminalontheinputblockforearthconnectionand notoneofthescrewsonthehousing; N’utilisezpasl’alimentationélectriquesansmiseàlaterreappropriée(Terreprotectrice).Utilisezleterminalsurleblocd’entréepourla connexionterrestreetnonpasunedesvissurleboîtier; 2. Turnpoweroffbeforeworkingonthedevice,protectagainstinadvertentre-powering; Éteignezl’alimentationavantdetravaillersurl’appareil,protégez-vouscontrelaréénergisationaccidentelle; 3. Makesurethatthewiringiscorrectbyfollowingalllocalandnationalcodes; Assurez-vousquelecâblageestcorrectensuivanttouslescodeslocauxetnationaux; 4. Donotmodifyorrepairtheunit; Nemodifiezpasouneréparezpasl’appareil; 5. Donotopentheunitashighvoltagesarepresentinside; Nemodifiezpasouneréparezpasl’appareil; 6. Usecautiontopreventanyforeignobjectsfromenteringthehousing; Fairepreuvedeprudencepourempêcherlesobjetsétrangersd’entrerdanslelogement; 7. Donotuseinwetlocationsorinareaswheremoistureorcondensationcanbeexpected; Fairepreuvedeprudencepourempêcherlesobjetsétrangersd’entrerdanslelogement; 8. Donottouchduringpower-on,andimmediatelyafterpower-off,hotsurfacesmaycauseburns; Netouchezpaspendantl’alimentationet,immédiatementaprèsl’alimentation,lessurfaceschaudespeuventcauserdesbrûlures. 9. Forambienttemperature≤60℃,use≥90℃ -copperwireonly;forambienttemperature>60℃ to85℃,use≥105℃ -copperwireonly; useonlywireswithaminimumdielectricstrengthof300V(input)and60V(output); Températureambiante≤60℃,utiliser≥90℃ -seulementfilsdecuivre;Températureambiante>60℃et85℃,utiliser≥105℃ -seulement filsdecuivre;UniquementpourI’ulilisationdefilsdecuivred’unerésisitanced’isolationminimalede300V(d’entrée)et60V(desortie). Note: 1. ForadditionalinformationonProductPackagingpleaserefertowww.mornsun-power.com.Packagingbagnumber:58220189; 2. Unlessotherwisespecified,parametersinthisdatasheetweremeasuredundertheconditionsofTa=25℃,humidity<90% RHwith nominalinputvoltageandratedoutputload; 3. Theroomtemperaturederatingof5℃/1000misneededforoperatingaltitudegreaterthan2000m; 4. Allindextestingmethodsinthisdatasheetarebasedonourcompanycorporatestandards; 5. Inordertoimprovetheefficiencyathighinputvoltage,therewillbeaudiblenoisegenerated,butitdoesnotaffectproduct performanceandreliability; 6. Wecanprovideproductcustomizationservice,pleasecontactourtechniciansdirectlyforspecificinformation; 7. Productsarerelatedtolawsandregulations:see"Features"and"EMC"; 8. Theoutcaseneedstobeconnectedtotheearth( )ofsystemwhentheterminalequipmentinoperating,see"Dimensionsand RecommendedLayout"; 9. OurproductsshallbeclassifiedaccordingtoISO14001andrelatedenvironmentallawsandregulations,andshallbehandledby qualifiedunits; 10. TheoutputvoltagecanbeadjustedbytheoutputadjustableresistanceADJ,turnitupclockwise; 11. TheunitsareOpenTypePowerSupplies,whichneedtobemountedinafire,mechanicallyandelectricallysafeenclosure; 12. Iftheequipmentisusedinamannernotspecifiedbymanufacture,theprotectionprovidedbytheequipmentmaybeimpaired. MornsunGuangzhouScience&TechnologyCo.,Ltd. Tel:86-20-38601850 Fax:86-20-38601272 E-mail:info@mornsun.cn www.mornsun-power.com