Technical content

File Name:LHP-200-SPEC 2018-04-08 LHP-200 seri es ■ Applications ■ Description ■ ModelEncoding Ratedwattage Seriesname LHP -- 200 ■ Features ‧UniversalACinput/Fullrange ‧Built-incurrentsharingfunction(2units) ‧Withpowergoodsignaloutput ‧Built-inactivePFCfunction ‧Lowleakagecurrent<1.0mA ‧Fanlessdesign,Coolingbyfreeairconvection ‧Protections:Shortcircuit/Overload/ Overvoltage/Overtemperature ‧3yearswarranty ‧LED electronic signage ‧LED display application ‧LED luminous characters ‧LEDTVwall ‧LEDchannelletter LHP-200seriesisa200WLEDdisplaypowersolution.Theultralowprofiledesignthatallowsthe heightandweightofthesignmoduletobeslim.Itgreatlysimplifiesthedeliveryandinstallation process.Accountingforhighefficiencyandenergysaving,theserieseffectivelyachieveselectricity reduction.ItissuitableforLEDsignagedisplay,movingsign,LEDchannelletterandLEDTVwalletc. Ratedoutputvoltage(4.2/4.6/5V) 200W Single Output with PFC Function

File Name:LHP-200-SPEC 2018-04-08 47 ~ 63Hz 168WRATED POWER(convection) 0.39kg;30pcs/13.82kg/0.69CUFT SPECIFICATION MODEL DC VOLTAGE RATED CURRENT OUTPUT LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE Note.4 FREQUENCY RANGE POWER FACTOR (Typ.) EFFICIENCY (Typ.)INPUT INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVER TEMPERATURE WORKING TEMP. STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MTBF DIMENSIONOTHERS NOTE PACKING OVER VOLTAGE AC CURRENT (Typ.) 2000ms, 100ms / 115AC 2000ms, 100ms / 230AC at full load 90 ~ 264VAC Cold start 40A/115VAC 80A/230VAC <1.0mA / 240VAC -40 ~ +80℃(Refer to “Derating Curve") -40 ~ +90℃, 5~ 95% RH non-condensing ±0.02%/℃ (0 ~ 50℃) 100K hrs min. MIL-HDBK-217F (25℃) PF≥0.95 / 230VAC at full load 10ms/230VAC 10ms/115VAC ±1.0% ±1.0% ±5.0% 200mVp-p 4.2V 40A RIPPLE & NOISE (max.) Note.2 VOLTAGE TOLERANCE Note.3 1.AllparametersNOTspeciallymentionedaremeasuredat230VACinput,ratedloadand25 ofambienttemperature. 2.Ripple&noisearemeasuredat20MHzofbandwidthbyusinga12"twistedpair-wireterminatedwitha0.1uf&47ufparallelcapacitor. 3.Tolerance:includessetuptolerance,lineregulationandloadregulation. 4.Deratingmaybeneededunderlowinputvoltages.Pleasecheckthederatingcurveformoredetails. 5. Theambient temperaturederatingof5 /1000misneededforoperatingaltitudegreaterthan2000m(6500ft) 6.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.ForguidanceonhowtoperformtheseEMCtests,pleasereferto“EMItestingofcomponentpowersupplies.”(asavailableonhttp://www. meanwell.com) ENVIRONMENT PROTECTION 220*50*26mm (L*W*H) Protection type :Hiccup mode, recovers automatically after fault condition is removed Protection type :Shut down O/P voltage, recovers automatically after temperature goes down 2.2A/115VAC 1.1A/230VAC Protection type : Hiccup mode, recovers automatically after fault condition is removed LHP-200 seri es LHP-200-4.2 SAFETY STANDARDS EMC EMISSION EMC IMMUNITY Compliance to EN55032,GB/T9254 Class B,EN61000-3-2,EN61000-3-3 SAFETY & EMC (Note.6) WITHSTAND VOLTAGE ISOLATION RESISTANCE I/P-O/P:3.0KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG,O/P-FG:≥10M Ohms/500VDC/25℃/ 70%RH Compliance to EN55024,EN61000-4-2,3,4,5,6,8,11; 90% 5.5~ 6V SHORT CIRCUIT Protection type : recovers automatically after fault condition is removed OVER LOAD 4.2~4.6V 200mVp-p 4.6V 40A 184W LHP-200-4.6 4.5~5V 200mVp-p 40A 200W LHP-200-5 91% 91% 125 ~ 175% rated output power 1 ~ 200Hz, 2G 10min./1cycle, period for 30min. each along X, Y, Z axes UL60950-1,EN60950-1 approved FUNCTION POWER GOOD 2.3~3.3V,10mA 200W Single Output with PFC Function 3.8~4.2VVOLTAGE RANGE

File Name:LHP-200-SPEC 2018-04-08 Block Diagram LHP-200 seri es STATIC CHARACTERISTIC AMBIENT TEMPERATURE (℃) LOAD (%) (HORIZONTAL)-40 0 15 30 40 50 60 70 80 100 INPUT VOLTAGE (V) 60Hz LOAD (%) 90 100 120 180 200 240 264 100 220160140110 CIRCUIT DETECTION O.L.P. EMI FILTER RECTIFIER PFC POWER SWITCH- FILTER &I/P FG ING CONTROL O.V.P. CIRCUIT RECTIFIERS O.T.P. File Name:LHP-200-SPEC 2018-04-08 LHP-200 seri es200W Single Output with PFC Function Derating Curve SHARING CURRENT CS DC OK

1.Share function PSU PSU LOAD CS+ CS+ GND GND P.G P.G File Name:LHP-200-SPEC 2018-04-08 LHP-200 seri es200W Single Output with PFC Function

Unit:mm File Name:LHP-200-SPEC 2018-04-08 LHP-200 seri es Pin No. Assignment AC/L AC/N AC Input Terminal pin NO. Assignment DC Output Terminal pin NO. Assignment Pin No. 1,2 3,4 Assignment 4.5 442 211 53.50 26220 1 2 3 Pin No. Assignment PG(Power Good) GND Function Connector(J1) CS+ 200W Single Output with PFC Function Terminal (Elinker) Terminal JIESHITAI A2001A-03-A1MA-P-D LW1C-8.25-3P-130-04A Max mounting torque 5Kgf-cm Terminal (Elinker) LW1B-8.25-6P-130-05A Max mounting torque 5Kgf-cm

1.Operate with additional aluminum plate aluminum plate(or the cabinet of the same size) on the bottom.The size of the suggested aluminum plate is shown as below. And for optimizing thermal performance, the aluminum plate must have an even and smooth surface In order to meet the“Derating Curve”and the “Static Characteristics” ,LHP-200 series must be installed onto an Installation 2.For heat dissipation, at least 5cm installation distance around the PSU should be kept, shown as below: M3*4 380 380 unit:mm 5cm 5cm5cm 5cm 5cm (or coated with thermal grease), and LHP-200 series must be firmly mounted at the center of the aluminum plate. LHP-200 seri es200W Single Output with PFC Function File Name:LHP-200-SPEC 2018-04-08