LFVLT110-1300 EOS | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 4

Technical content

Features

AC Input 90-264 V, Universal Input Frequency 47-63 Hz Input Current 120 V AC: 2.4 A max. 230 V AC: 1.2 A max. Inrush Current 120 V AC: 35 A max. 230 V AC: 65 A max. Leakage Current 120 V AC: < 500 µA 230 V AC: < 1000 µA Efficiency 120 V AC: 80% typical 230 V AC: 82% typical Hold-up Time 120 V AC: 15 ms 230 V AC: 22 ms Output Power 80 to 110 W Line Regulation +/-0.3% Load Regulation Transient Response < 10%, 50% to 100% load change, 50/60 Hz, 50% duty cycle, 0.1 A/µs, recovery time < 5 ms Rise T ime < 40 ms Set Point T olerance Over Current Protection 110 to 160% Over V oltage Protection Short Circuit Protection Short term with autorecovery < 6 s Switching Frequency Boost converter: 45 kHz typical Resonant converter: 45 kHz typical Operating T emperature 0 to 70°C, refer derating curve Storage T emperature -40 to +70°C Relative Humidity 95% Rh, noncondensing Altitude Operating: 10,000 ft.; Nonoperating: 40,000 ft. MTBF 1.97m Hours, T elcordia SR332 Issue-3 Isolation Voltage Min. 4242 VDC between input and output Cooling Convection: 80 W; 150 LFM: 110 W 4EM-19-180 1 39-DE60-49919-002 / B2

LFVLT110 -1300 V1=5.1 V 12.0 A 18.0 A 0.1 A 1% LFVLT110 -1301 V1=12 V 6.8 A 9.2 A 0.4 A 1% LFVLT110 -1302 V1=15 V 5.5 A 7.3 A 0.4 A 1% LFVLT110 -1303 V1=24 V 3.33 A 4.6 A 0.1 A 1% LFVLT110 -1304 V1=48 V 1.7 A 2.3 A 0.2 A 1% LFVLT80 -CK metal cover kit accessory Notes 1. Maximum current per output channel. Do not exceed total output power rating. 2. Ripple is peak to peak with 20 MHz bandwidth and 10 µF (Electrolytic capacitor) in parallel with a 0.1 µF capacitor at rated line voltage and load ranges. 3. Power fail and power good signal on quad output models only. 4. Specifications are for nominal input voltage, 25°C and max. load unless otherwise stated. 5. Derate output power linearly to 80% from 90 VAC to 80 VAC input. Model Number Voltage Max. Load1 Max. Load1 Min. Load Ripple2 (Convection) (150 LFM) Connectors J1 Pin 1 AC NEUTRAL Pin 2 AC LINE Spade Connector EARTH J2 Pin 1, 2, 3, 4 V1 Pin 5, 6, 7, 8 RTN Pin 9, 10 V2 Pin 11 V3 Pin 12 V4 J3 Pin 1 RTN Pin 2 POWER FAIL/GOOD 4EM-19-180 2 39-DE60-49919-002 / B2 Downloaded fromArrow.com.

AC Input Connector (J1) Molex: 26-60-4030 or equivalent Mating: 09-50-3031; Pins: 08-50-0106 EARTH Molex: 19705-4301 Mating: 190030001 DC Output Connector (J2) Tyco: 1-640445-2 or equivalent Mating: 1-647402-2; Pins: 3-647409-1 Signal Connector (J3) Molex: 22-23-2021 or equivalent Mating: 22-01-2021 Dimensions 5.0 x 3.04 x 1.07 inches (127.0 x 77.22 x 27.18 mm) Weight 250 g Mechanical Specifications CE Mark Complies with LVD Directive Conducted Emissions EN55022-B, CISPR22-B, FCC PART15-B Static Discharge EN61000-4-2, Level-3 RF Field Susceptibility EN61000-4-3, Level-3 Fast Transients/Bursts EN61000-4-4, Level-3 Radiated Emissions EN55022-B, CISPR22-B, FCC PART15-B To be controlled in end system Surge Susceptibility EN61000-4-5, Level-3 Harmonic Current EN61000-3-2, Class A EMC Safety Standard(s) IEC60950-1 (ed.2), EN60950-1, UL60950-1 (2nd Edition), CSA C22.2 No. 60950-1 (2nd Edition), Class 1 SELV Approval Agency Nemko, UL, C-UL Safety File Number(s) Nemko: P09210934 UL: E150565 Safety Power Fail/Good Signal3 Signal goes high after a delay of 100 ms once main output is within regulation band. Signal goes low 1 ms advance before output goes out of regulation due to mains failure Signal 4EM-19-180 3 39-DE60-49919-002 / B2

4EM-19-180 4 39-DE60-49919-002 / B2 Notes: In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following 1. Stand off, used to mount PCB has OD of 5.4 mm max. 2. Screws, used to fix PCB on stand off, have head dia of 6.0 mm max. 3. Washer, if used, to have dia of 6.5 mm max. Downloaded fromArrow.com.