LFA15F RSG | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 18
Technical content
AC-DC Power Supplies Open Frame/ Enclosed type LF A 10 F -O-O
Ordering information
C : with Coating G: Low leakage current J1: VH(J.S.T.)connector type S : with Chassis SN: with Chassis & cover Y: with Potentiometer Specification is changed at option, refer to Instruction Manual. 1 2 3 4 5 6 This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care. MODEL LFA10F-3R3-Y LFA10F-5 LFA10F-12 LFA10F-15 LFA10F-24 MAX OUTPUT WATTAGE[W] 6.6 10 10.8 10.5 12 DC OUTPUT 3.3V 2A 5V 2A 12V 0.9A 15V 0.7A 24V 0.5A SPECIFICATIONS MODEL LFA10F-3R3-Y LFA10F-5 LFA10F-12 LFA10F-15 LFA10F-24 INPUT VOLTAGE[V] AC85 - 264 1f (Refer to Instruction Manual 1.1 and 3.2) *3 CURRENT[A] ACIN 100V 0.18typ (Io=100%) 0.26typ (Io=100%) ACIN 200V 0.11typ (Io=100%) 0.16typ (Io=100%) FREQUENCY[Hz] 50 / 60 (47 - 440) INRUSH CURRENT[A] ACIN 100V 15typ (Io=100%) ACIN 200V 30typ (Io=100%) LEAKAGE CURRENT[mA] 0.15/0.30max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) OUTPUT VOLTAGE[V] 3.3 5 12 15 24 LINE REGULATION[mV] *5 20max 20max 48max 60max 96max LOAD REGULATION[mV] *5 40max 40max 100max 120max 150max RIPPLE[mVp-p] 0 to +50C 80max 80max 120max 120max 120max -10 - 0C 140max 140max 160max 160max 160max Io=0 - 35% 190max 160max 240max 240max 280max RIPPLE NOISE[mVp-p] 0 to +50C 120max 120max 150max 150max 150max -10 - 0C 160max 160max 180max 180max 180max Io=0 - 35% 240max 240max 300max 300max 320max TEMPERATURE REGULATION[mV] 0 to +50C 50max 50max 120max 150max 240max -10 to +50C 60max 60max 150max 180max 290max DRIFT[mV] *2 20max 20max 48max 60max 96max START-UP TIME[ms] 200typ (ACIN 100V, Io=100%)ɹ*Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage. HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%) OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 to 3.63 Fixed ( lYz option is available for adjusting output voltage between ±10%) PROTECTION CIRCUIT AND OTHERS OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically OPERATING INDICATION Not provided REMOTE SENSING Not provided REMOTE ON/OFF Not provided ISOLATION INPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) OUTPUT-FG AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature) ENVIRONMENT OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000 feet) max *3 STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis SAFETY AND NOISE REGULATIONS AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B CE MARKING Low Voltage Directive, EMC Directive HARMONIC ATTENUATOR Complies with IEC61000-3-2 (Class A) *6 (Not built-in to active fi lter) *4 OTHERS CASE SIZE/WEIGHT 50X22X73.5mm [1.97X0.87X2.89 inches] (WXHXD) / 55g max (without chassis and cover) COOLING METHOD Convection (Refer to Instruction Manual 3.1 and 3.2) *3 *1 This is the value that measured on measuring board with capacitor of 22mF at 150mm from output terminal. Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM103). A circuit reducing standby power is built in this unit. Therefore, the internal switch element is intermittent operated, and the Ripple/Ripple Noise specifi cation in load factor Io=0-35% is different. Please refer to the Instruction Manual 1.7. *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. *3 Derating is required. *4 When two or more units are operating it may not comply with the IEC61000-3-2. Please contact us for details. *5 Please contact us about dynamic load and input response. *6 Please contact us about another class. * To meet the specifi cations. Do not operate over-loaded condition. * Parallel operation is not possible. * Derating is required when operated with chassis and cover. * Sound noise may be generated by power supply in case of pulse load. Recommended EMI/EMC Filter NAC-04-472 High voltage pulse noise type : NAP series Low leakage current type : NAM series * The EMI/EMC Filter is recommended to connect with several devices. LFA OG NHCKPFF .(#
<PIN CONNECTION> CN1 CN2 Pin No. Input
1 AC(L)
3 AC(N)
Pin No. Output 1- V 2+ V I/O Connector Mating connector CN1 1-1123724-3 1-1123722-5 Chain Loose CN2 1-1123723-2 1-1123722-2 Terminal Chain Loose 1123721-1 1318912-1 1123721-1 1318912-1 (Mfr:Tyco Electronics) ¶ The back side of P.C.B. of the power supply is assembled some SMDs. Be attention not to bump against the attached area by vibration. ¶ Use the spacer of 8mm length or more regarding insulation. And do not use press-fitting bush. ¶ Point A, Point B are thermometry points. Please refer to Instruction Manual 3. ¶ I/O Connector is Mfr. Tyco Electronics ¶ Option:-J1:(J.S.T) connector type. Refer to Instruction Manual 5. ¶ Tolerance : ±1 [±0.04] ¶ Weight : 55g max (without chassis and cover) ¶ PCB material / thickness : CEM3 / 1.6mm ¶ Optional chassis and cover material : Electric galvanizing steel board. ¶ Dimensions in mm, [ ]=inches ¶ Mounting torque (Mounting hole of chassis) : 0.6N-m (6.3kgf-cm) max Standard type 5 FG CN2 CN1 Point A Point B Output(+) Output(-) Voltage adjust (LFA10F-3R3-Y or optional) 2-f3.5 Mounting Hole Input(N) Input(L) Name plate ¶1 Surface mount device PCB t=1.6 63.5 ±0.55 73.5 4max 18 50 40 ±0.5 5 f3.5 4-M3 Mounting Hole f3.5 2-M3 Mounting Hole Output(+) Output(-) FG Input(L) Input(N) CN1 CN2 Chassis and cover type 93.5 3.5 3.5 583.5 ±0.5 16 11 1530 ±0.5 583.5 ±0.5 31.7 4.6FG [0.2] [0.2] [1.97][0.71][0.16] [1.25] [0.59] [0.14] [0.14] [0.43][0.63] [1.26] [1.18] [2.36] [2.89] [0.18] [0.2] [0.2] [3.68] [2.5] [3.29] [3.29] [1.57] [1.18] AC IN 85 264V NOISE FILTER CONTROL INVERTER RECTIFIER AND FILTER RECTIFIER AND FILTER DC OUT FG TRANSFORMER CONTROL FUSE AC250V Photocoupler Photocoupler OVER VOLTAGE PROTECTION CURRENT SENSING INRUSH CURRENT LIMIT LFA OG NHCKPFF .(#
AC-DC Power Supplies Open Frame/ Enclosed type LF A 15 F - ˘- ˘ 0SEFSJOHJOGPSNBUJPO 1 2 3 4 5 6 1Series name 2Single output 3Output wattage 4Universal input 5Output voltage 6Optional C : with Coating G: Low leakage current J1: VH(J.S.T.)connector type S : with Chassis SN: with Chassis & cover Y: with Potentiometer Specification is changed at option, refer to Instruction Manual. This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care. MODEL LFA15F-3R3-Y LFA15F-5 LFA15F-12 LFA15F-15 LFA15F-24 MAX OUTPUT WATTAGE[W] 9.9 15 15.6 15 16.8 DC OUTPUT 3.3V 3A 5V 3A 12V 1.3A 15V 1A 24V 0.7A SPECIFICATIONS MODEL LFA15F-3R3-Y LFA15F-5 LFA15F-12 LFA15F-15 LFA15F-24 INPUT VOLTAGE[V] AC85 - 264 1f (Refer to Instruction Manual 1.1 and 3.2) *3 CURRENT[A] ACIN 100V 0.24typ (Io=100%) 0.35typ (Io=100%) ACIN 200V 0.15typ (Io=100%) 0.20typ (Io=100%) FREQUENCY[Hz] 50 / 60 (47 - 440) INRUSH CURRENT[A] ACIN 100V 15typ (Io=100%) (At cold start) (Ta=25C) ACIN 200V 30typ (Io=100%) (At cold start) (Ta=25C) LEAKAGE CURRENT[mA] 0.15/0.30max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) OUTPUT VOLTAGE[V] 3.3 5 12 15 24 LINE REGULATION[mV] *5 20max 20max 48max 60max 96max LOAD REGULATION[mV] *5 40max 40max 100max 120max 150max RIPPLE[mVp-p] 0 to +50C 80max 80max 120max 120max 120max -10 - 0C 140max 140max 160max 160max 160max Io=0 - 35% 190max 160max 240max 240max 280max RIPPLE NOISE[mVp-p] 0 to +50C 120max 120max 150max 150max 150max -10 - 0C 160max 160max 180max 180max 180max Io=0 - 35% 240max 240max 300max 300max 320max TEMPERATURE REGULATION[mV] 0 to +50C 50max 50max 120max 150max 240max -10 to +50C 60max 60max 150max 180max 290max DRIFT[mV] *2 20max 20max 48max 60max 96max START-UP TIME[ms] 200typ (ACIN 100V, Io=100%)ɹ*Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage. HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%) OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 to 3.63 Fixed ( lYz option is available for adjusting output voltage between ±10%) PROTECTION CIRCUIT AND OTHERS OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically OPERATING INDICATION Not provided REMOTE SENSING Not provided REMOTE ON/OFF Not provided ISOLATION INPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) OUTPUT-FG AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature) ENVIRONMENT OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000 feet) max *3 STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis SAFETY AND NOISE REGULATIONS AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B CE MARKING Low Voltage Directive, EMC Directive HARMONIC ATTENUATOR Complies with IEC61000-3-2 (Class A) *6 (Not built-in to active fi lter) *4 OTHERS CASE SIZE/WEIGHT 50X22X87.5mm [1.97X0.87X3.44 inches] (WXHXD) / 80g max (without chassis and cover) COOLING METHOD Convection (Refer to Instruction Manual 3.1 and 3.2) *3 *1 This is the value that measured on measuring board with capacitor of 22mF at 150mm from output terminal. Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM103). A circuit reducing standby power is built in this unit. Therefore, the internal switch element is intermittent operated, and the Ripple/Ripple Noise specifi cation in load factor Io=0-35% is different. Please refer to the Instruction Manual 1.7. *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. *3 Derating is required. *4 When two or more units are operating it may not comply with the IEC61000-3-2. Please contact us for details. *5 Please contact us about dynamic load and input response. *6 Please contact us about another class. * To meet the specifi cations. Do not operate over-loaded condition. * Parallel operation is not possible. * Derating is required when operated with chassis and cover. * Sound noise may be generated by power supply in case of pulse load. Recommended EMI/EMC Filter NAC-04-472 High voltage pulse noise type : NAP series Low leakage current type : NAM series * The EMI/EMC Filter is recommended to connect with several devices. LFA OG NHCKPFF .(#
2.5A Photocoupler Photocoupler OVER VOLTAGE PROTECTION CURRENT SENSING INRUSH CURRENT LIMIT <PIN CONNECTION> CN1 CN2 Pin No. Input Pin No. Output 1- V 2+ V I/O Connector Mating connector CN1 1-1123724-3 1-1123722-5 Chain Loose CN2 1-1123723-2 1-1123722-2 Terminal Chain Loose 1123721-1 1318912-1 1123721-1 1318912-1 (Mfr:Tyco Electronics) ¶ I/O Connector is Mfr. Tyco Electronics ¶ Option:-J1:(J.S.T) connector type. Refer to Instruction Manual 5. ¶ Tolerance : ±1 [±0.04] ¶ Weight : 80g max (without chassis and cover) ¶ PCB material / thickness : CEM3 / 1.6mm ¶ Optional chassis and cover material : Electric galvanizing steel board. ¶ Dimensions in mm, [ ]=inches ¶ Mounting torque (Mounting hole of chassis) : 0.6N-m (6.3kgf-cm) max Standard type Chassis and cover type ¶ The back side of P.C.B. of the power supply is assembled some SMDs. Be attention not to bump against the attached area by vibration. ¶ Use the spacer of 8mm length or more regarding insulation. And do not use press-fitting bush. ¶ Point A, Point B are thermometry points. Please refer to Instruction Manual 3. 5 FG CN1 CN2 Point A Point B Output(-) Output(+) Voltage adjust (LFA15F-3R3-Y or optional) 2-f3.5 Mounting Hole Input(N) Input(L) Name plate PCB t=1.6 40 ±0.5 5 77.5 ±0.5 87.5 184max CN1 1FG Input(L) Input(N) Output(-) Output(+)CN2 4-M3 Mounting Hole f3.5 f3.5 2-M3 Mounting Hole 3.5 107.5 3.5 597.5 ±0.5 1530 ±0.5 597.5 ±0.5 16 11 ¶1 Surface mount device 29.7 4.4FG [0.2] [0.2] [1.97][0.71][0.16] [1.17] [0.59] [0.14] [0.14] [0.43][0.63] [1.26] [1.18] [2.36] [3.44] [0.17] [0.2] [0.2] [4.23] [3.05] [3.84] [3.84] [1.57] [1.18] LFA OG NHCKPFF .(#
AC-DC Power Supplies Open Frame/ Enclosed type LF A 30 F - ˘- ˘ 0SEFSJOHJOGPSNBUJPO 1 2 3 4 5 6 1Series name 2Single output 3Output wattage 4Universal input 5Output voltage 6Optional C : with Coating G: Low leakage current J1: VH(J.S.T.)connector type S : with Chassis SN: with Chassis & cover Y: with Potentiometer Specification is changed at option, refer to Instruction Manual. This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care. MODEL LFA30F-3R3-Y LFA30F-5 LFA30F-12 LFA30F-15 LFA30F-24 DC OUTPUT 3.3V 6A 5V 6A 12V 2.5A 15V 2A 24V 1.3A SPECIFICATIONS MODEL LFA30F-3R3-Y LFA30F-5 LFA30F-12 LFA30F-15 LFA30F-24 INPUT VOLTAGE[V] AC85 - 264 1f (Refer to Instruction Manual 1.1 and 3.2) *3 CURRENT[A] ACIN 100V 0.50typ (Io=100%) 0.65typ (Io=100%) ACIN 200V 0.30typ (Io=100%) 0.35typ (Io=100%) FREQUENCY[Hz] 50 / 60 (47 - 440) EFFICIENCY[%] ACIN 100V 73typ 76typ 79typ 81typ 82typ ACIN 200V 75typ 79typ 81typ 83typ 84typ INRUSH CURRENT[A] ACIN 100V 15typ (Io=100%) (At cold start) (Ta=25C) ACIN 200V 30typ (Io=100%) (At cold start) (Ta=25C) LEAKAGE CURRENT[mA] 0.30 / 0.65max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) OUTPUT VOLTAGE[V] 3.3 5 12 15 24 LINE REGULATION[mV] *5 20max 20max 48max 60max 96max LOAD REGULATION[mV] *5 40max 40max 100max 120max 150max RIPPLE[mVp-p] 0 to +50C *1 80max 80max 120max 120max 120max -10 - 0C *1 140max 140max 160max 160max 160max RIPPLE NOISE[mVp-p] 0 to +50C *1 120max 120max 150max 150max 150max -10 - 0C *1 160max 160max 180max 180max 180max TEMPERATURE REGULATION[mV] 0 to +50C 50max 50max 120max 150max 240max -10 to +50C 60max 60max 150max 180max 290max DRIFT[mV] *2 20max 20max 48max 60max 96max START-UP TIME[ms] 150typ (ACIN 100V, Io=100%) HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%) OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 to 3.63 Fixed ( lYz option is available for adjusting output voltage between ±10%) PROTECTION CIRCUIT AND OTHERS OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically OPERATING INDICATION Not provided REMOTE SENSING Not provided REMOTE ON/OFF Not provided ISOLATION INPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) OUTPUT-FG AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature) ENVIRONMENT OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000feet) max *3 STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis SAFETY AND NOISE REGULATIONS AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B CE MARKING Low Voltage Directive, EMC Directive HARMONIC ATTENUATOR Complies with IEC61000-3-2 (Class A) *6 (Not built-in to active fi lter) *4 OTHERS CASE SIZE/WEIGHT 50X26.5X105mm [1.97X1.04X4.13 inches] (WXHXD) / 130g max (without chassis and cover) COOLING METHOD Convection (Refer to Instruction Manual 3.1 and 3.2) *3 *1 This is the value that measured on measuring board with capacitor of 22 mF at 150mm from output terminal. Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM103). *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. *3 Derating is required. *4 When two or more units are operating it may not comply with the IEC61000-3-2. Please contact us for details. *5 Please contact us about dynamic load and input response. *6 Please contact us about another class. * To meet the specifi cations. Do not operate over-loaded condition. * Parallel operation is not possible. * Derating is required when operated with chassis and cover. * Sound noise may be generated by power supply in case of pulse load. Recommended EMI/EMC Filter NAC-04-472 High voltage pulse noise type : NAP series Low leakage current type : NAM series * The EMI/EMC Filter is recommended to connect with several devices. LFA OG NHCKPFF .(#
3.15A Photocoupler Photocoupler OVER VOLTAGE PROTECTION CURRENT SENSING INRUSH CURRENT LIMIT <PIN CONNECTION> CN1 CN2 Pin No. Input Pin No. Output 1, 2 -V 3, 4 +V ¶ Keep drawing current per pin below 5A for CN2. I/O Connector Mating connector CN1 1-1123724-3 1-1123722-5 Chain Loose CN2 1-1123723-4 1-1123722-4 Terminal Chain Loose 1123721-1 1318912-1 1123721-1 1318912-1 (Mfr:Tyco Electronics) ¶ I/O Connector is Mfr. Tyco Electronics ¶ Option:-J1:(J.S.T) connector type. Refer to Instruction Manual 5. ¶ Tolerance : ±1 [±0.04] ¶ Weight: 130g max (without chassis and cover) ¶ PCB material / thickness : CEM3 / 1.6mm ¶ Optional chassis and cover material : Electric galvanizing steel board. ¶ Dimensions in mm, [ ]=inches ¶ Mounting torque (Mounting hole of chassis) : 0.6N-m (6.3kgf-cm) max Standard type Chassis and cover type Mounting Hole Point BPoint A PCB t=1.6 Input(L) Input(N) Voltage adjust (LFA30F-3R3-Y or optional) Output(+) Output(-) 3-f3.5 Mounting Hole Name plate 5 FG CN1 CN2 105 95 ±0.5 503.5max 23 40 ±0.5 3.5 CN2 CN1 Output(-) Output(+) FG Input(L) Input(N) f3.5 2-M3 Mounting Hole 4-M3 Mounting Hole f3.5 3.5 125 3.5 5115 ±0.5 1530 ±0.5 16 11 5115 ±0.5 ¶ 4 Mounting holes are existing. ¶ The back side of P.C.B. of the power supply is assembled some SMDs. Be attention not to bump against the attached area by vibration. ¶ Use the spacer of 8mm length or more regarding insulation. And do not use press-fitting bush. ¶ Point A, Point B are thermometry points. Please refer to Instruction Manual 3. ¶1 Surface mount device 35.8 4.5FG [0.2] [0.16] [0.2] [1.97][0.91][0.14] [1.41] [0.14] [0.59] [0.14] [0.14] [0.43][0.63] [1.42] [1.18] [2.36] [4.13] [0.18] [0.2] [0.2] [4.92] [3.74] [4.53] [4.53] [1.57] [1.18] LFA OG NHCKPFF .(#
AC-DC Power Supplies Open Frame/ Enclosed type LF A 50 F - ˘ - ˘ 0SEFSJOHJOGPSNBUJPO 1 2 3 4 5 6 1Series name 2Single output 3Output wattage 4Universal input 5Output voltage 6Optional C : with Coating G: Low leakage current J1: VH(J.S.T.)connector type S : with Chassis SN: with Chassis & cover Y: with Potentiometer Specification is changed at option, refer to Instruction Manual. This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care. MODEL LFA50F-3R3-Y LFA50F-5 LFA50F-12 LFA50F-15 LFA50F-24 LFA50F-36 LFA50F-48 SPECIFICATIONS MODEL LFA50F-3R3-Y LFA50F-5 LFA50F-12 LFA50F-15 LFA50F-24 LFA50F-36 LFA50F-48 INPUT VOLTAGE[V] AC85 - 264 1f (Refer to Instruction Manual 1.1 and 3.2) *3 CURRENT[A] ACIN 100V 0.47typ (Io=100%) 0.67typ (Io=100%) ACIN 200V 0.27typ (Io=100%) 0.36typ (Io=100%) FREQUENCY[Hz] 50 / 60 (47 - 63) POWER FACTOR (Io=100%) ACIN 100V 0.96typ 0.97typ ACIN 200V 0.83typ 0.90typ INRUSH CURRENT[A] ACIN 100V 15typ (Io=100%) (At cold start) (Ta=25C) ACIN 200V 30typ (Io=100%) (At cold start) (Ta=25C) LEAKAGE CURRENT[mA] 0.40 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) OUTPUT VOLTAGE[V] 3.3 5 12 15 24 36 48 LINE REGULATION[mV] *4 20max 20max 48max 60max 96max 144max 192max LOAD REGULATION[mV] *4 40max 40max 100max 120max 150max 240max 240max RIPPLE[mVp-p] 0 to +50C *1 80max 80max 120max 120max 120max 150max 150max -10 - 0C *1 140max 140max 160max 160max 160max 200max 200max RIPPLE NOISE[mVp-p] 0 to +50C *1 120max 120max 150max 150max 150max 250max 250max -10 - 0C *1 160max 160max 180max 180max 180max 300max 300max TEMPERATURE REGULATION[mV] 0 to +50C 50max 50max 120max 150max 240max 360max 480max -10 to +50C 60max 60max 150max 180max 290max 450max 600max DRIFT[mV] *2 20max 20max 48max 60max 96max 144max 192max START-UP TIME[ms] 350typ (ACIN 100V, Io=100%) HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%) OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 to 3.63 Fixed ( lYz option is available for adjusting output voltage between ±10%) PROTECTION CIRCUIT AND OTHERS OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically OPERATING INDICATION Not provided REMOTE SENSING Not provided REMOTE ON/OFF Not provided ISOLATION INPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) OUTPUT-FG AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature) ENVIRONMENT OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000feet) max *3 STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis SAFETY AND NOISE REGULATIONS AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B CE MARKING Low Voltage Directive, EMC Directive HARMONIC ATTENUATOR Complies with IEC61000-3-2 (Class A) *5 OTHERS CASE SIZE/WEIGHT 50X26.5X132mm [1.97X1.04X5.20 inches] (WXHXD) / 165g max (without chassis and cover) COOLING METHOD Convection (Refer to Instruction Manual 3.1 and 3.2) *3 *1 This is the value that measured on measuring board with capacitor of 22 mF at 150mm from output terminal. Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM103). *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. *3 Derating is required. *4 Please contact us about dynamic load and input response. *5 Please contact us about another class. * To meet the specifi cations. Do not operate over-loaded condition. * Parallel operation is not possible. * Derating is required when operated with chassis and cover. * Sound noise may be generated by power supply in case of pulse load. Recommended EMI/EMC Filter NAC-04-472 High voltage pulse noise type : NAP series Low leakage current type : NAM series * The EMI/EMC Filter is recommended to connect with several devices. LFA OG NHCKPFF .(#
250V2.5A CONTROL INVERTER DC OUT TRANSFORMER CONTROL Photocoupler Photocoupler OVER VOLTAGE PROTECTION CURRENT SENSING INRUSH CURRENT LIMIT RECTIFIER AND FILTER RECTIFIER AND FILTER <PIN CONNECTION> CN1 CN2 Pin No. Input Pin No. Output 1, 2 -V 3, 4 +V ¶ Keep drawing current per pin below 5A for CN2. I/O Connector Mating connector CN1 1-1123724-3 1-1123722-5 Chain Loose CN2 1-1123723-4 1-1123722-4 Terminal Chain Loose 1123721-1 1318912-1 1123721-1 1318912-1 (Mfr:Tyco Electronics) ¶ I/O Connector is Mfr. Tyco Electronics ¶ Option:-J1:(J.S.T) connector type. Refer to Instruction Manual 5. ¶ Mounting torque (Mounting hole of chassis) : 0.6N-m (6.3kgf-cm) max ¶ Tolerance : ±1 [±0.04] ¶ Weight : 165g max (without chassis and cover) ¶ PCB material / thickness : CEM3 / 1.6mm ¶ Optional chassis and cover material : Electric galvanizing steel board. ¶ Dimensions in mm, [ ]=inches Standard type Chassis and cover type ¶ 4 Mounting holes are existing. ¶ The back side of P.C.B. of the power supply is assembled some SMDs. Be attention not to bump against the attached area by vibration. ¶ Use the spacer of 8mm length or more regarding insulation. And do not use press-fitting bush. ¶ Point A, Point B are thermometry points. Please refer to Instruction Manual 3. 5 FG CN2 CN1 Name plate Voltage adjust (LFA50F-3R3-Y or optional) 3-f3.5 Mounting Hole Output(-) Output(+) Mounting Hole Point BPoint A Input(L) Input(N) PCB t=1.6 3.5 132 40 ±0.5 122 ±0.5 233.5max Output(-) Output(+) FG Input(N) Input(L) 4-M3 Mounting Hole 2-M3 Mounting Hole 2-f3.5 f3.5 CN1 CN2 162 150 ±0.5 3.5 3.515 10 1040 ±0.5 2020 ±0.5 6150 ±0.5 ¶1 Surface mount device 15.2 4.9FG [0.2] [0.16] [0.2] [1.97][0.91][0.14] [0.6][0.14] [0.79] [0.39] [0.14] [0.14] [0.39][0.59] [1.42] [1.18] [2.36] [5.2] [0.19] [0.24] [0.24] [6.38] [4.8] [5.91] [5.91] [1.57] [0.79] [1.57] LFA OG NHCKPFF .(#
AC-DC Power Supplies Open Frame/ Enclosed type LF A 75 F - ˘ - ˘ 0SEFSJOHJOGPSNBUJPO 1 2 3 4 5 6 1Series name 2Single output 3Output wattage 4Universal input 5Output voltage 6Optional C : with Coating G: Low leakage current J1: VH(J.S.T.)connector type S : with Chassis SN: with Chassis & cover Y: with Potentiometer Specification is changed at option, refer to Instruction Manual. This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care. MODEL LFA75F-3R3-Y LFA75F-5 LFA75F-12 LFA75F-15 LFA75F-24 LFA75F-36 LFA75F-48 SPECIFICATIONS MODEL LFA75F-3R3-Y LFA75F-5 LFA75F-12 LFA75F-15 LFA75F-24 LFA75F-36 LFA75F-48 INPUT VOLTAGE[V] AC85 - 264 1f (Refer to Instruction Manual 1.1 and 3.2) *3 CURRENT[A] ACIN 100V 0.70typ (Io=100%) 1.00typ (Io=100%) ACIN 200V 0.40typ (Io=100%) 0.50typ (Io=100%) FREQUENCY[Hz] 50 / 60 (47 - 63) POWER FACTOR (Io=100%) ACIN 100V 0.96typ 0.97typ ACIN 200V 0.83typ 0.90typ INRUSH CURRENT[A] ACIN 100V 15typ (Io=100%) (At cold start) (Ta=25C) ACIN 200V 30typ (Io=100%) (At cold start) (Ta=25C) LEAKAGE CURRENT[mA] 0.40 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) OUTPUT VOLTAGE[V] 3.3 5 12 15 24 36 48 LINE REGULATION[mV] *4 20max 20max 48max 60max 96max 144max 192max LOAD REGULATION[mV] *4 40max 40max 100max 120max 150max 240max 240max RIPPLE[mVp-p] 0 to +50C *1 80max 80max 120max 120max 120max 150max 150max -10 - 0C *1 140max 140max 160max 160max 160max 200max 200max RIPPLE NOISE[mVp-p] 0 to +50C *1 120max 120max 150max 150max 150max 250max 250max -10 - 0C *1 160max 160max 180max 180max 180max 300max 300max TEMPERATURE REGULATION[mV] 0 to +50C 50max 50max 120max 150max 240max 360max 480max -10 to +50C 60max 60max 150max 180max 290max 450max 600max DRIFT[mV] *2 20max 20max 48max 60max 96max 144max 192max START-UP TIME[ms] 350typ (ACIN 100V, Io=100%) HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%) OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 to 3.63 Fixed ( lYz option is available for adjusting output voltage between ±10%) PROTECTION CIRCUIT AND OTHERS OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically OPERATING INDICATION Not provided REMOTE SENSING Not provided REMOTE ON/OFF Not provided ISOLATION INPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) OUTPUT-FG AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature) ENVIRONMENT OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000feet) max *3 STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis SAFETY AND NOISE REGULATIONS AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B CE MARKING Low Voltage Directive, EMC Directive HARMONIC ATTENUATOR Complies with IEC61000-3-2 (Class A) *5 OTHERS CASE SIZE/WEIGHT 50X33.5X150mm [1.97X1.32X5.91 inches] (WXHXD) / 230g max (without chassis and cover) COOLING METHOD Convection (Refer to Instruction Manual 3.1 and 3.2) *3 *1 This is the value that measured on measuring board with capacitor of 22 mF at 150mm from output terminal. Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM103). *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. *3 Derating is required. *4 Please contact us about dynamic load and input response. *5 Please contact us about another class. * To meet the specifi cations. Do not operate over-loaded condition. * Parallel operation is not possible. * Derating is required when operated with chassis and cover. * Sound noise may be generated by power supply in case of pulse load. Recommended EMI/EMC Filter NAC-04-472 High voltage pulse noise type : NAP series Low leakage current type : NAM series * The EMI/EMC Filter is recommended to connect with several devices. LFA OG NHCKPFF .(#
250V3.15A CONTROL INVERTER DC OUT TRANSFORMER CONTROL Photocoupler Photocoupler OVER VOLTAGE PROTECTION CURRENT SENSING INRUSH CURRENT LIMIT RECTIFIER AND FILTER RECTIFIER AND FILTER <PIN CONNECTION> CN1 CN2 Pin No. Input Pin No. Output 1 to 3 -V 4 to 6 +V ¶ Keep drawing current per pin below 5A for CN2. I/O Connector Mating connector CN1 1-1123724-3 1-1123722-5 Chain Loose CN2 1-1123723-6 1-1123722-6 Terminal Chain Loose 1123721-1 1318912-1 1123721-1 1318912-1 (Mfr:Tyco Electronics) ¶ I/O Connector is Mfr. Tyco Electronics ¶ Option:-J1:(J.S.T) connector type. Refer to Instruction Manual 5. ¶ Mounting torque (Mounting hole of chassis) :1.5N-m (16kgf-cm) max ¶ Tolerance : ±1 [±0.04] ¶ Weight : 230g max (without chassis and cover) ¶ PCB material / thickness : CEM3 / 1.6mm ¶ Optional chassis and cover material : Electric galvanizing steel board. ¶ Dimensions in mm, [ ]=inches Standard type Chassis and cover type ¶ 4 Mounting holes are existing. ¶ The back side of P.C.B. of the power supply is assembled some SMDs. Be attention not to bump against the attached area by vibration. ¶ Use the spacer of 8mm length or more regarding insulation. And do not use press-fitting bush. ¶ Point A, Point B are thermometry points. Please refer to Instruction Manual 3. PCB t=1.6 Input(N) Input(L) Point A Point B Mounting Hole Output(+) Output(-) 3-f3.5 Mounting Hole Voltage adjust (LFA75F-3R3-Y or optional) Name plate FG CN2 CN1 6 140 ±0.5 150 3.5 5 40 ±0.5 3.5max 30 CN1 CN2 2-M4 Mounting Hole f4.5 2-f4.5 4-M4 Mounting Hole Input(L) Input(N) FG Output(+) Output(-) 4.5 4.5 180 2020 ±0.5 15 15 5.5169 ±0.5 5.5169 ±0.5 1040 ±0.5 ¶1 Surface mount device 17.8 13FG [0.2] [0.16] [0.2] [1.97] [1.18][0.14] [0.7][0.14] [0.79] [0.39] [0.18] [0.18] [0.59][0.59] [1.77] [1.18] [2.36] [5.91] [0.51] [0.22] [0.22] [7.09] [5.51] [6.65] [6.65] [1.57] [0.79] [1.57] LFA OG NHCKPFF .(#
AC-DC Power Supplies Open Frame/ Enclosed type LF A 100 F - ˘ - ˘ 0SEFSJOHJOGPSNBUJPO 1 2 3 4 5 6 1Series name 2Single output 3Output wattage 4Universal input 5Output voltage 6Optional *1 C : with Coating G: Low leakage current with the function to be acceptable to output peak current (only 24V) J1: VH(J.S.T.)connector type R: with Remote ON/OFF R2: with Remote ON/OFF S : with Chassis SN: with Chassis & cover Y: with Potentiometer This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care. MODEL LFA100F-3R3-Y LFA100F-5-Y LFA100F-12 LFA100F-15 LFA100F-24 LFA100F-24-H LFA100F-36 LFA100F-48 SPECIFICATIONS MODEL LFA100F-3R3-Y LFA100F-5-Y LFA100F-12 LFA100F-15 LFA100F-24 LFA100F-24-H LFA100F-36 LFA100F-48 INPUT VOLTAGE[V] AC85 - 264 1f (Refer to Instruction Manual 1.1 and 3.2) *4 CURRENT[A] ACIN 100V 0.9typ ʢIo=100%ʣ 1.3typ (Io=100%) ACIN 200V 0.5typ ʢIo=100%ʣ 0.7typ (Io=100%) FREQUENCY[Hz] 50 / 60 (47 - 63) POWER FACTOR (Io=100%) ACIN 100V 0.98typ 0.99typ ACIN 200V 0.92typ 0.95typ INRUSH CURRENT[A] ACIN 100V 15typ (Io=100%) (At cold start) (Ta=25C) ACIN 200V 30typ (Io=100%) (At cold start) (Ta=25C) LEAKAGE CURRENT[mA] 0.40 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) OUTPUT VOLTAGE[V] 3.3 5 12 15 24 24 36 48 LINE REGULATION[mV] *7 20max 20max 48max 60max 96max 96max 144max 192max LOAD REGULATION[mV] *7 40max 40max 100max 120max 150max 150max 240max 240max RIPPLE[mVp-p] 0 to +50C *2 80max 80max 120max 120max 120max 240max 150max 150max -10 - 0C *2 140max 140max 160max 160max 160max 320max 200max 200max RIPPLE NOISE[mVp-p] 0 to +50C *2 120max 120max 150max 150max 150max 300max 250max 250max -10 - 0C *2 160max 160max 180max 180max 180max 360max 300max 300max TEMPERATURE REGULATION[mV] 0 to +50C 50max 50max 120max 150max 240max 240max 360max 480max -10 to +50C 60max 60max 150max 180max 290max 290max 450max 600max DRIFT[mV] *3 20max 20max 48max 60max 96max 96max 144max 192max START-UP TIME[ms] 350typ (ACIN 100V, Io=100%) HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%) OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 to 3.63 4.50 to 5.50 Fixed ( lYz option is available for adjusting output voltage) PROTECTION CIRCUIT AND OTHERS OVERCURRENT PROTECTION Works over 105% of rating (works over 101% of peak current at option -H) and recovers automatically OPERATING INDICATION Not provided REMOTE SENSING Not provided REMOTE ON/OFF Option (Refer to Instruction Manual) ISOLATION INPUT-OUTPUT.RC *6 AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) OUTPUT.RC-FG *6 AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature) OUTPUT-RC *6 AC100V 1minute, Cutoff current = 25mA, DC100V 10MW min (At Room Temperature) ENVIRONMENT OPERATING TEMP.,HUMID.AND ALTITUDE *4 -10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis SAFETY AND NOISE REGULATIONS AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B HARMONIC ATTENUATOR Complies with IEC61000-3-2 (Class A) *8 OTHERS CASE SIZE/WEIGHT 62X33.5X155mm [2.44X1.32X6.10 inches] (WXHXD) / 280g max (without chassis and cover) COOLING METHOD Convection (Refer to Instruction Manual 3.1 and 3.2) *4 Recommended EMI/EMC Filter NAC-04-472 High voltage pulse noise type : NAP series Low leakage current type : NAM series * The EMI/EMC Filter is recommended to connect with several devices. *1 Specifi cation is changed at option, refer to Instruction Manual. *2 This is the value that measured on measuring board with capacitor of 22mF at 150mm from output terminal. Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM103). *3 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. *4 Derating is required. *5 ( ) means peak current. There is a possibility that an internal device is damaged when the specifi cation is exceeded. Please contact us about the detail. *6 Applicable when Remote ON/OFF (optional) is added. *7 Please contact us about dynamic load and input response. *8 Please contact us about another class. * To meet the specifi cations. Do not operate over-loaded condition. * Parallel operation is not possible. * Derating is required when operated with chassis and cover. * Sound noise may be generated by power supply in case of pulse load. Please refer to Instruction manual 5. LFA OG NHCKPFF .(#
¶ Tolerance : ±1 [±0.04] ¶ Optional chassis and cover material : Electric galvanizing steel board. ¶ Weight : 280g max (without chassis and cover) ¶ PCB material : CEM3 ¶ Dimensions in mm, [ ]=inches Standard type Chassis and cover type ¶ 4 Mounting holes are existing. ¶ The back side of P.C.B. of the power supply is assembled some SMDs. Be attention not to bump against the attached area by vibration. ¶ Use the spacer of 8mm length or more regarding insulation. And do not use press-fitting bush. ¶ Point A, Point B are thermometry points. Please refer to Instruction Manual 3. Barrier strip type Model B2B-XH-A Mating Connector (Terminal) RC(-) RC(+) ContentsPIN No. or SXH-001T-P0.6 BXH-001T-P0.6 XHP-2 CN4 Option (Mfr:J.S.T) Connector type <PIN CONNECTION> CN1 CN2 Pin No. Input Pin No. Output 1 to 4 -V 5 to 8 +V ¶ Keep drawing current per pin below 5A for CN2. I/O Connector Mating connector CN1 1-1123724-3 1-1123722-5 Chain Loose CN2 1-1123723-8 1-1123722-8 Terminal Chain Loose 1123721-1 1318912-1 1123721-1 1318912-1 (Mfr:Tyco Electronics) ¶ I/O Connector is Mfr. Tyco Electronics ¶ Option:-J1:VH(J.S.T) connector type. ¶ Mounting torque (Mounting hole of chassis) :1.5N-m (16kgf-cm) max ¶ External size of option is different from standard model. Output(-) Output(+) FG Input(N) Input(L) 4-M4 Mounting Hole 2-f4.5 2-M4 Mounting Hole f4.5 CN2 CN1 PCB t=1.6 Name plate Connector for Remote ON/OFF (Optional) CN4 Voltage adjust (LFA100F-3R3-Y,LFA100F-5-Y or Optional) Mounting Hole 3-f3.5 Mounting Hole Point A Point B
1 Input(L)
3 Input(N)
Output(+) Output(-) 4.5 185 4.5 303.5max 52±0.55 5 145±0.5 16.5 155 3.5 6173±0.5 2325±0.5 1345±0.5 6173±0.5 20 15 FG ¶1 Surface mount device [0.2] [0.65] [0.16] [0.2] [2.44] [1.18][0.14] [0.14] [0.91] [0.51] [0.18] [0.18] [0.59][0.79] [1.77] [1.42] [2.83] [6.1] [0.24] [0.24] [7.28][5.71] [6.81] [6.81] [2.05] [0.98] [1.77] FG DC OUT AC IN 85 - 264V RC E 250V3.15A INRUSH CURRENT LIMIT RECTIFIER AND FILTER CONTROL TRANSFORMER CONTROL OVER VOLTAGE PROTECTION NOISE FILTER RECTIFIER AND FILTER INVERTER FUSE RECTIFIER CURRENT SENSING BOOSTER INDUCTER INVERTER CONTROL CURRENT SENSING EXTERNAL SOURCE OPTION Photocoupler Photocoupler Photocoupler LFA OG NHCKPFF .(#
AC-DC Power Supplies Open Frame/ Enclosed type LF A 150 F - ˘ - ˘ 0SEFSJOHJOGPSNBUJPO 1 2 3 4 5 6 1Series name 2Single output 3Output wattage 4Universal input 5Output voltage 6Optional *1 C : with Coating G: Low leakage current with the function to be acceptable to output peak current (only 24V) J1: VH(J.S.T.)connector type R: with Remote ON/OFF R2: with Remote ON/OFF S : with Chassis SN: with Chassis & cover Y: with Potentiometer This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care. MODEL LFA150F-3R3-Y LFA150F-5-Y LFA150F-12 LFA150F-15 LFA150F-24 LFA150F-24-H LFA150F-36 LFA150F-48 SPECIFICATIONS MODEL LFA150F-3R3-Y LFA150F-5-Y LFA150F-12 LFA150F-15 LFA150F-24 LFA150F-24-H LFA150F-36 LFA150F-48 INPUT VOLTAGE[V] AC85 - 264 1f (Refer to Instruction Manual 1.1 and 3.2) *4 CURRENT[A] ACIN 100V 1.4typ ʢIo=100%ʣ 2.0typ ʢIo=100%ʣ ACIN 200V 0.7typ ʢIo=100%ʣ 1.0typ ʢIo=100%ʣ FREQUENCY[Hz] 50 / 60 (47 - 63) POWER FACTOR (Io=100%) ACIN 100V 0.98typ 0.99typ ACIN 200V 0.92typ 0.95typ INRUSH CURRENT[A] ACIN 100V 15typ (Io=100%) (At cold start) (Ta=25C) ACIN 200V 30typ (Io=100%) (At cold start) (Ta=25C) LEAKAGE CURRENT[mA] 0.40 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) OUTPUT VOLTAGE[V] 3.3 5 12 15 24 24 36 48 LINE REGULATION[mV] *7 20max 20max 48max 60max 96max 96max 144max 192max LOAD REGULATION[mV] *7 40max 40max 100max 120max 150max 150max 240max 240max RIPPLE[mVp-p] 0 to +40C *2 80max 80max 120max 120max 120max 240max 150max 150max -10 - 0C *2 140max 140max 160max 160max 160max 320max 200max 200max RIPPLE NOISE[mVp-p] 0 to +40C *2 120max 120max 150max 150max 150max 300max 250max 250max -10 - 0C *2 160max 160max 180max 180max 180max 360max 300max 300max TEMPERATURE REGULATION[mV] 0 to +40C 50max 50max 120max 150max 240max 240max 360max 480max -10 to +40C 60max 60max 150max 180max 290max 290max 450max 600max DRIFT[mV] *3 20max 20max 48max 60max 96max 96max 144max 192max START-UP TIME[ms] 350typ (ACIN 100V, Io=100%) HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%) OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 to 3.63 4.50 to 5.50 Fixed ( lYz option is available for adjusting output voltage) PROTECTION CIRCUIT AND OTHERS OVERCURRENT PROTECTION Works over 105% of rating (works over 101% of peak current at option -H) and recovers automatically OPERATING INDICATION Not provided REMOTE SENSING Not provided REMOTE ON/OFF Option (Refer to Instruction Manual) ISOLATION INPUT-OUTPUT.RC *6 AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) OUTPUT.RC-FG *6 AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature) OUTPUT-RC *6 AC100V 1minute, Cutoff current = 25mA, DC100V 10MW min (At Room Temperature) ENVIRONMENT OPERATING TEMP.,HUMID.AND ALTITUDE *4 -10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis SAFETY AND NOISE REGULATIONS AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B HARMONIC ATTENUATOR Complies with IEC61000-3-2 (Class A) *8 OTHERS CASE SIZE/WEIGHT 75X37.0X160mm [2.95X1.46X6.30 inches] (WXHXD) / 390g max (without chassis and cover) COOLING METHOD Convection (Refer to Instruction Manual 3.1 and 3.2) *4 Recommended EMI/EMC Filter NAC-04-472 High voltage pulse noise type : NAP series Low leakage current type : NAM series * The EMI/EMC Filter is recommended to connect with several devices. Please refer to Instruction manual 5. *1 Specifi cation is changeed at option, refer to Instruction Manual. *2 This is the value that measured on measuring board with capacitor of 22mF at 150mm from output terminal. Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM103). *3 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. *4 Derating is required. *5 ( ) means peak current. There is a possibility that an internal device is damaged when the specifi cation is exceeded. Please contact us about the detail. *6 Applicable when remote control (optional) is added. *7 Please contact us about dynamic load and input response. *8 Please contact us about another class. * To meet the specifi cations. Do not operate over-loaded condition. * Parallel operation is not possible. * Derating is required when operated with chassis and cover. * Sound noise may be generated by power supply in case of pulse load. LFA OG NHCKPFF .(#
¶ Tolerance : ±1 [±0.04] ¶ Optional chassis and cover material : Electric galvanizing steel board. ¶ Dimensions in mm, [ ]=inches Standard type Chassis and cover type ¶ 4 Mounting holes are existing. ¶ The back side of P.C.B. of the power supply is assembled some SMDs. Be attention not to bump against the attached area by vibration. ¶ Use the spacer of 8mm length or more regarding insulation. And do not use press-fitting bush. ¶ Point A, Point B are thermometry points. Please refer to Instruction Manual 3. <PIN CONNECTION> CN1 CN2 CN3 Pin No. Input ¶ Keep drawing current per pin below 5A for CN2,CN3. Pin No. Output 1 to 6 +V Pin No. Output 1 to 7 -V I/O Connector Mating connector CN1 1-1123724-3 1-1123722-5 Chain Loose CN2 1-1123723-6 1-1123722-6 (Mfr:Tyco Electronics) Terminal Chain Loose 1123721-1 1318912-1 1123721-1 1318912-1 CN3 1-1123723-7 1-1123722-7 Chain Loose 1123721-1 1318912-1 ¶ I/O Connector is Mfr. Tyco Electronics ¶ Option:-J1:VH(J.S.T) connector type. ¶ Mounting torque (Mounting hole of chassis) :1.5N-m (16kgf-cm) max ¶ External size of option is different from standard model. Barrier strip type Model B2B-XH-A Mating Connector (Terminal) RC(-) RC(+) ContentsPIN No. or SXH-001T-P0.6 BXH-001T-P0.6 XHP-2 CN4 Option (Mfr:J.S.T) Connector type FG 2 1 2-M4 Mounting Hole f4.5 2-f4.5 Output(-) Output(+) CN3 CN2 FG Input(N) Input(L) CN1 Output(-) Output(+) CN3 CN2 PCB t=1.6 Name plate Mounting Hole 3-f3.5 CN1 FG5 Input(N)3 Input(L)1 Point A Point B Mounting Hole Connector for Remote ON/OFF (optional)Voltage adjust (LFA150F-3R3-Y,LFA150F-5-Y or Optional) 2 1CN4 4-M4 Mounting Hole 55±0.5 4.5 188 4.5 33.53.5max 6.5 160 5 65±0.5 150±0.5 3.5 20 15 6176±0.5 2535±0.5 6176±0.5 ¶ Weight : 390g max (without chassis and cover) ¶ PCB material : CEM3 ¶1 Surface mount device [0.2] [0.71] [0.16] [0.2] [2.95] [1.32][0.14] [0.14] [0.26] [0.98] [0.59] [0.18] [0.18] [0.59][0.79] [1.85] [1.65] [3.35] [6.3] [0.24] [0.24] [7.4] [5.91] [6.93] [6.93] [2.6] [1.38] [2.17] FG DC OUT AC IN 85 - 264V RC E 250V5A INRUSH CURRENT LIMIT RECTIFIER AND FILTER CONTROL TRANSFORMER CONTROL OVER VOLTAGE PROTECTION NOISE FILTER RECTIFIER AND FILTER INVERTER FUSE RECTIFIER CURRENT SENSING BOOSTER INDUCTER INVERTER CONTROL CURRENT SENSING EXTERNAL SOURCE OPTION Photocoupler Photocoupler Photocoupler LFA OG NHCKPFF .(#
AC-DC Power Supplies Open Frame/ Enclosed type LF A 240 F - ˘ - ˘ 0SEFSJOHJOGPSNBUJPO 1 2 3 4 5 6 1Series name 2Single output 3Output wattage 4Universal input 5Output voltage 6Optional *1 C : with Coating G: Low leakage current with the function to be acceptable to output peak current (only 24V) J1: VH(J.S.T.)connector type R: with Remote ON/OFF R2 : with Remote ON/OFF S : with Chassis SN: with Chassis & cover T : Vertical terminal block Y: with Potentiometer This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care. MODEL LFA240F-24 LFA240F-24-H LFA240F-36 LFA240F-48 MAX OUTPUT WATTAGE[W] *5 240 240 (300) 241.2 240 DC OUTPUT *5 24V 10A 24V 10 (12.5)A 36V 6.7A 48V 5A SPECIFICATIONS MODEL LFA240F-24 LFA240F-24-H LFA240F-36 LFA240F-48 INPUT VOLTAGE[V] AC85 - 264 1f (Refer to Instruction Manual 1.1 and 3.2) *4 CURRENT[A] ACIN 100V 3.3typ ʢIo=100%ʣ ACIN 200V 1.7typ ʢIo=100%ʣ FREQUENCY[Hz] 50 / 60 (47 - 63) EFFICIENCY[%] ACIN 100V 84.5typ 84.5typ 84.5typ 84.5typ ACIN 200V 87.5typ 87.5typ 87.5typ 87.5typ POWER FACTOR (Io=100%) ACIN 100V 0.99typ ACIN 200V 0.95typ INRUSH CURRENT[A] ACIN 100V 15 / 30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start) ACIN 200V 30 / 30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start) LEAKAGE CURRENT[mA] 0.40 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) OUTPUT VOLTAGE[V] 24 24 36 48 CURRENT[A] *5 10 10 (Peak12.5) 6.7 5 LINE REGULATION[mV] *7 96max 96max 144max 192max LOAD REGULATION[mV] *7 150max 150max 240max 240max RIPPLE[mVp-p] 0 to +40C *2 120max 240max 150max 150max -10 - 0C *2 160max 320max 200max 200max RIPPLE NOISE[mVp-p] 0 to +40C *2 150max 300max 250max 250max -10 - 0C *2 180max 360max 300max 300max TEMPERATURE REGULATION[mV] 0 to +40C 240max 240max 360max 480max -10 to +40C 290max 290max 450max 600max DRIFT[mV] *3 96max 96max 144max 192max START-UP TIME[ms] 350typ (ACIN 100V, Io=100%) HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%) OUTPUT VOLTAGE ADJUSTMENT RANGE[V] Fixed ( lYz option is available for adjusting output voltage) PROTECTION CIRCUIT AND OTHERS OVERCURRENT PROTECTION Works over 105% of rating (works over 101% of peak current at option -H) and recovers automatically OPERATING INDICATION Not provided REMOTE SENSING Not provided REMOTE ON/OFF Option (Refer to Instruction Manual) ISOLATION INPUT-OUTPUT.RC *6 AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) OUTPUT.RC-FG *6 AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature) OUTPUT-RC *6 AC100V 1minute, Cutoff current = 25mA, DC100V 10MW min (At Room Temperature) ENVIRONMENT OPERATING TEMP.,HUMID.AND ALTITUDE *4 -10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis SAFETY AND NOISE REGULATIONS AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B HARMONIC ATTENUATOR Complies with IEC61000-3-2 (Class A) *8 OTHERS CASE SIZE/WEIGHT 84X46.5X180mm [3.31X1.83X7.09 inches] (WXHXD) / 550g max (without chassis and cover) COOLING METHOD Convection (Refer to Instruction Manual 3.1 and 3.2) *4 Recommended EMI/EMC Filter NAC-06-472 High voltage pulse noise type : NAP series Low leakage current type : NAM series *1 Specifi cation is changeed at option, refer to Instruction Manual. *2 This is the value that measured on measuring board with capacitor of 22mF at 150mm from output terminal. Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM103). *3 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. *4 Derating is required. *5 ( ) means peak current. There is a possibility that an internal device is damaged when the specifi cation is exceeded. Please contact us about the detail. *6 Applicable when remote control (optional) is added. *7 Please contact us about dynamic load and input response. *8 Please contact us about another class. * To meet the specifi cations. Do not operate over-loaded condition. * Parallel operation is not possible. * Derating is required when operated with chassis and cover. * Sound noise may be generated by power supply in case of pulse load. Please refer to Instruction manual 5. LFA OG NHCKPFF .(#
¶ Tolerance : ±1 [±0.04] ¶ Optional chassis and cover material : Electric galvanizing steel board. ¶ Dimensions in mm, [ ]=inches Standard type Chassis and cover type ¶ 5 Mounting holes are existing. ¶ The back side of P.C.B. of the power supply is assembled some SMDs. Be attention not to bump against the attached area by vibration. ¶ Use the spacer of 8mm length or more regarding insulation. And do not use press-fitting bush. ¶ Point A, Point B are thermometry points. Please refer to Instruction Manual 3. <PIN CONNECTION> CN1 CN2 CN3 Pin No. Input ¶ Keep drawing current per pin below 5A for CN2,CN3. Pin No. Output 1 to 6 +V Pin No. Output 1 to 7 -V I/O Connector Mating connector CN1 1-1123724-3 1-1123722-5 Chain Loose CN2 1-1123723-6 1-1123722-6 (Mfr:Tyco Electronics) Terminal Chain Loose 1123721-1 1318912-1 1123721-1 1318912-1 CN3 1-1123723-7 1-1123722-7 Chain Loose 1123721-1 1318912-1 Barrier strip type Model B2B-XH-A Mating Connector (Terminal) RC(-) RC(+) ContentsPIN No. or SXH-001T-P0.6 BXH-001T-P0.6 XHP-2 CN4 Option (Mfr:J.S.T) Connector type ¶ I/O Connector is Mfr. Tyco Electronics ¶ Option:-J1:VH(J.S.T) connector type. ¶ Mounting torque (Mounting hole of chassis) :1.5N-m (16kgf-cm) max ¶ External size of option is different from standard model. CN1 CN4 FG Connector for Remote ON/OFF (Optional) Voltage adjust(Optional) Output(-) Output(+) Input(L) PCB t=1.6 Name plate Input(N) Mounting Hole Point A Point B Mounting Hole CN2 CN3 4-f3.5 CN1 CN2 CN3Input(N) FG Input(L) Output(+) Output(-) 4-M4 Mounting Hole 2-f4.5 2-M4 Mounting Hole f4.5 16.5 180 170±0.55 5 74±0.5 89±0.5 4 3.5 21 3.5max 4.5 212 4.5 6200±0.5 30 15 6200±0.5 26.545±0.5 16.565±0.5 FG ¶ Weight : 550g max (without chassis and cover) ¶ PCB material : CEM3 ¶1 Surface mount device [0.2] [0.65] [0.16] [0.2] [3.31] [1.69][0.14] [0.14] [0.83] [1.04] [0.65] [0.18] [0.18] [0.59][1.18] [2.32] [1.93] [3.86] [7.09] [0.24] [0.24] [8.35][6.69] [3.5] [7.87] [7.87] [2.91] [1.77] [2.56] FG DC OUT AC IN 85 - 264V RC E INRUSH CURRENT LIMIT RECTIFIER AND FILTER CONTROL TRANSFORMER CONTROL OVER VOLTAGE PROTECTION NOISE FILTER RECTIFIER AND FILTER INVERTER RECTIFIER CURRENT SENSING BOOSTER INDUCTER INVERTER CONTROL CURRENT SENSING EXTERNAL SOURCE OPTION Photocoupler Photocoupler Photocoupler 250V10A FUSE LFA OG NHCKPFF .(#
AC-DC Power Supplies Open Frame/ Enclosed type LF A 300 F - ˘ - ˘ 0SEFSJOHJOGPSNBUJPO 1 2 3 4 5 6 1Series name 2Single output 3Output wattage 4Universal input 5Output voltage 6Optional *1 C : with Coating G: Low leakage current with the function to be acceptable to output peak current (Only 24V, 30V, 36V and 48V) J : EP (Tyco Electronics) connector type (Except 3.3V and 5V) J1 : VH (J.S.T.) connector type (Except 3.3V and 5V) R: with Remote ON/OFF R2 : with Remote ON/OFF S : with Chassis SNF: with Chassis & cover & fan (Only 5V, 12V and 24V) T1: Holizontal terminal blockThis power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care. MODEL LFA300F-3R3-TY LFA300F-5-TY LFA300F-12-TY LFA300F-15-TY LFA300F-24-TY LFA300F-24-HTY LFA300F-30-TY LFA300F-36-TY LFA300F-48-TY MAX OUTPUT WATTAGE[W] *5 198 300 324 330 336 336 (456) 330 338.4 336 DC OUTPUT *5 Forced air 3.3V 60A 5V 60A 12V 27A 15V 22A 24V 14A 24V 14 (19)A 30V 11A 36V 9.4A 48V 7A SPECIFICATIONS MODEL LFA300F-3R3-TY LFA300F-5-TY LFA300F-12-TY LFA300F-15-TY LFA300F-24-TY LFA300F-24-HTY LFA300F-30-TY LFA300F-36-TY LFA300F-48-TY INPUT VOLTAGE[V] AC85 - 264 1f (Refer to Instruction Manual 1.1 and 3.2) *4 CURRENT[A] ACIN 100V 2.7typ ʢIo=100%ʣ 4.1typ ʢIo=100%ʣ ACIN 200V 1.4typ ʢIo=100%ʣ 2.0typ ʢIo=100%ʣ FREQUENCY[Hz] 50 / 60 (47 - 63) POWER FACTOR (Io=100%) ACIN 100V 0.98typ 0.99typ ACIN 200V 0.92typ 0.95typ INRUSH CURRENT[A] ACIN 100V 15 / 30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start) ACIN 200V 30 / 30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start) LEAKAGE CURRENT[mA] 0.45 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) OUTPUT VOLTAGE[V] 3.3 5 12 15 24 24 30 36 48 CURRENT[A] *5 Convection 40 40 17 14 12.5 12.5 (Peak19) 10 8.4 6.3 Forced air 60 60 27 22 14 14 (Peak19) 11 9.4 7 LINE REGULATION[mV] *7 20max 20max 48max 60max 96max 96max 144max 144max 192max LOAD REGULATION[mV] *7 40max 40max 100max 120max 150max 150max 240max 240max 240max RIPPLE[mVp-p] 0 to +40C *2 80max 80max 120max 120max 120max 240max 150max 150max 150max -10 - 0C *2 140max 140max 160max 160max 160max 320max 200max 200max 200max RIPPLE NOISE[mVp-p] 0 to +40C *2 120max 120max 150max 150max 150max 300max 250max 250max 250max -10 - 0C *2 160max 160max 180max 180max 180max 360max 300max 300max 300max TEMPERATURE REGULATION[mV] 0 to +40C 50max 50max 120max 150max 240max 240max 360max 360max 480max -10 to +40C 60max 60max 150max 180max 290max 290max 450max 450max 600max DRIFT[mV] *3 20max 20max 48max 60max 96max 96max 144max 144max 192max START-UP TIME[ms] 350typ (ACIN 100V, Io=100%) HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%) PROTECTION CIRCUIT AND OTHERS OVERCURRENT PROTECTION Works over 105% of rating (works over 101% of peak current at option -H) and recovers automatically OPERATING INDICATION Not provided REMOTE SENSING Not provided REMOTE ON/OFF Option (Refer to Instruction Manual) ISOLATION INPUT-OUTPUT.RC *6 AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) OUTPUT.RC-FG *6 AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature) OUTPUT-RC *6 AC100V 1minute, Cutoff current = 25mA, DC100V 10MW min (At Room Temperature) ENVIRONMENT OPERATING TEMP.,HUMID.AND ALTITUDE *4 -10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis SAFETY AND NOISE REGULATIONS AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B HARMONIC ATTENUATOR Complies with IEC61000-3-2 (Class A) *8 OTHERS CASE SIZE/WEIGHT 95X52.5X222mm [3.74X2.07X8.74 inches] (WXHXD) (without terminal block) / 810g max COOLING METHOD Convection / Forced air (Refer to Instruction Manual 3.1 and 3.2) *4 Recommended EMI/EMC Filter NAC-06-472 High voltage pulse noise type : NAP series Low leakage current type : NAM series *1 Specifi cation is changeed at option, refer to Instruction Manual. *2 This is the value that measured on measuring board with capacitor of 22mF at 150mm from output terminal. Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM103). *3 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. *4 Derating is required. *5 ( ) means peak current. There is a possibility that an internal device is damaged when the specifi cation is exceeded. Please contact us about the detail.. *6 Applicable when remote control (optional) is added. *7 Please contact us about dynamic load and input response. *8 Please contact us about another class. * To meet the specifi cations. Do not operate over-loaded condition. * Parallel operation is not possible. * Derating is required when operated with chassis and cover. * Sound noise may be generated by power supply in case of pulse load. Please refer to Instruction manual 5. LFA OG NHCKPFF .(#
¶ External size of option is different from standard model. Standard type ¶ 5 Mounting holes are existing. ¶ The back side of P.C.B. of the power supply is assembled some SMDs. Be attention not to bump against the attached area by vibration. ¶ Use the spacer of 8mm length or more regarding insulation. And do not use press-fitting bush. ¶ Point A, Point B, Point C, Point D are thermometry points. Please refer to Instruction Manual 3. ¶ Keep drawing current per pin below 20A for TB2. Barrier strip type Model B2B-XH-A Mating Connector (Terminal) RC(-) RC(+) ContentsPIN No. or SXH-001T-P0.6 BXH-001T-P0.6 XHP-2 CN4 Option (Mfr:J.S.T) Connector type Output(+) Output(-) TB2 Input(N) FG Input(L)TB1 Point DPoint C Connector for Remote ON/OFF (Optional) CN4 Point B Point A PCB t=1.6 Voltage adjust Mounting Hole 4-f3.5 Mounting Hole Name plate 18.5 10 8.6 222 52.5 8.6 5 109±0.5 212±0.5 5.5 46.5 85±0.55 3.5max 3.5 ¶ Tolerance : ±1 [±0.04] ¶ Dimensions in mm, [ ]=inches ¶ Screw tightening torque : M4 1.6N-m (16.9kgf-cm) max ¶ Weight : 810g max (without chassis and cover) ¶ PCB material : CEM3 FG ¶1 Surface mount device [0.2] [1.83] [0.16] [0.2] [2.07] [0.39] [0.34] [3.74] [1.93][0.14] [0.14] [0.22] [8.74] [4.29] [8.35] [3.35] FG DC OUT AC IN 85 - 264V RC E INRUSH CURRENT LIMIT RECTIFIER AND FILTER CONTROL TRANSFORMER CONTROL OVER VOLTAGE PROTECTION NOISE FILTER RECTIFIER AND FILTER INVERTER RECTIFIER CURRENT SENSING BOOSTER INDUCTER INVERTER CONTROL CURRENT SENSING EXTERNAL SOURCE OPTION 250V10A FUSE Photocoupler Photocoupler Photocoupler LFA OG NHCKPFF .(#