Miniature Waterproof Shielded Connectors LF Series ■Features 1. Ease of shielded termination and connector assembly All components are self-aligning and do not require complex assembly tooling. The shield of the cable is connected with the metal housing of the connector using simple shielding clamp, supplied with the connector. 2. Water and dust protected IP67 protection rating. Complete protection against dust penetration and against water penetration when mated assembly is submerged at the depth of 1.8 meter for 48 hours. 3. Bayonet lock Short turn bayonet lock assures secure vibration resistant mating of the connectors. 4. High current rating capacity 5. RoHS compliant All components and materials comply with the requirements of the EU Directive 2002/95/EC. ■Applications Sensors, robots, injection molding machines, NC, factory automation equipment, surveying instruments, measuring instruments, medical equipment, surveillance cameras and base stations. 2008.5 NEW Mating: Insert the plug, and then turn the locking collar clockwise, as indicated by the coupling direction marking. PlugLocking collarReceptacle Un-mating: Turn the locking collar counter-clockwise than pull off the plug. Coupling direction marking Coupling direction marking 36.4 Receptacle Plug Ø13 8.9 mm max. (3 pos.) Mated dimensions Short turn bayonet lock Built-in shield connection spring Cable shielding connection clamp Cable Shielding Connection - Plug Number of contacts 6, 12 and 20 Current rating 5A max. 10A max. 2A max. 10A max. 2A max. The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.

LF Series●Miniature Waterproof Shielded Connectors 1A DC Frequency: 10 to 500Hz, single amplitude of 0.75mm, acceleration of 98 m/s2 for 3 hours in 3 axis. Acceleration of 490m/s2, 11ms duration, sine half-wave waveform, 3 cycles in each of the 3 axis. 1000 cycles Temperature: -55ç ➝ Room temperature ➝ +125ç ➝ Room temperature Time: 30 ➝ 10 to 15 ➝ 30 ➝ 10 to 15 (minutes) 5 cycles 96 hours at temperature of 40ç and humidity of 90% to 95%. Complete dust protection. No water penetration when submerged for 48 hours at the depth of 1.8 meter. No electrical discontinuity for 10μs max. No electrical discontinuity for 10μs max. Insulation resistance: 100 Mø min. Insulation resistance: 110 Mø min. (When temperature high) Insulation resistance: 100 Mø min. (Dray state) When mated with corresponding connector. 1000 Mø min. 30 mø max. (3, 6, 12, 20 pos.) 10 mø max. (4 pos.) 10 mø max.(A to D), 30 mø max.(1 to 7)(11pos.) 500V DC (3, 4 pos.) 100V DC (6, 12, 20 pos.) 500V DC (A to D), 100V DC (1 to 7)(11pos.) No flashover or insulation breakdown. 1250V AC/one minute (3, 4 pos.) 300V AC/one minute (6, 12, 20 pos.) 1250V AC(A to D),300V AC(1 to 7) / one minute(11pos.) 11.Contact resistance 12.Insulation resistance 13.Withstanding voltage 14.Vibration 15.Shock 16.Durability 16.(Mating/un-mating) 17.Temperature cycle 18.Humidity 19.Water / dust protection 15 mø max. (3, 6, 12, 20 pos.) 15 mø max. (4 pos.) 15 mø max. (A to D), 15mø max. (1 to 7)(11 pos.) Rating Voltage rating Current rating Operating temperature range Storage temperature range –25ç to +85ç (Note 1) –25ç to +85ç (Note 2) 125V AC, 175V DC (3 pos.) 125V AC, 125V DC (4 pos.) 30V AC, 42V DC (6 pos. , 12pos. , 20pos.) 125V AC, DC (11 pos. A to D) 30V AC, 42V DC (11 pos. 1 to 7) 5A max. (3 pos.) 10A max. (4 pos.) 2A max. (6 pos. , 12pos. , 20pos.) 10A(11 pos. A to D), 2A(11 pos. 1 to 7) ■Product Specifications Item Specification Conditions Material Finish / Color Remarks UL94V-0 Body / back shell Insulator Contacts Gasket Zinc alloy PPS Copper alloy Chloroprene rubber Nickel plated Black Gold plated Black ■Materials / Finish Note 1: Includes temperature rise caused by the current flow. Note 2: The term “storage” refers to products stored for long period of time prior to mounting and use. Operating temperature r ange and humidity range covers non-conducting condition of installed connectors in storage, shipment or during transportation. ■Ordering Information Series name : LF Shell size 07 Waterproof W : Waterproof type Lock Mechanism B : Bayonet lock Connector type P : Plug R : Receptacle J : Jack Number of contacts : 3, 4, 6, 11, 12, 20 Contact type P : Male contact S : Female contact -- S6PBW07LF 1 2 3 4 5 6 7 Components The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.

LF Series●Miniature Waterproof Shielded Connectors Note: Recommended hex nut tightening torque: 1.5 to 2 N·m (3,4,6, and 12 pos.), 2 to 2.5 N·m (11, 20 pos.) ■Plugs ØA B ØC (Cable dia.) E ØA ØB C D F(HEX) ■Receptacles Unit:mm (Shown one example) (Shown one example) Unit:mm Part number CL No. Contact Number of contacts ØA ØB ØCC D E Weight RoHS LF07WBR-3P LF07WBR-3S LF07WBR-6P LF07WBR-6S LF10WBR-4P LF10WBR-4S LF10WBR-12P LF10WBR-12S LF13WBR-20P LF13WBR-20S LF13WBR-11P LF13WBR-11S 136-1003-2 136-1004-5 136-1001-7 136-1002-0 136-1005-8 136-1006-0 136-1007-3 136-1008-6 136-1009-9 136-1010-8 136-1011-0 136-1012-3 Male Female Male Female Male Female Male Female Male Female Male Female 10.3 12.8 15.9 15.3 18.3 19.05 7.75 15.15 15.05 15.25 19.05 17.25 7.65 7.75 1M9∞0.75 M11∞0.75 M14∞0.75 10g 10g YES F Part number CL No. Contact Number of contacts ØA B ØC Weight RoHS LF07WBP-3S LF07WBP-3P LF07WBP-6S LF07WBP-6P LF10WBP-4S LF10WBP-4P LF10WBP-12S LF10WBP-12P LF13WBP-20S LF13WBP-20P LF13WBP-11S LF13WBP-11P 136-0003-7 136-0004-0 136-0001-1 136-0002-4 136-0005-2 136-0006-5 136-0007-8 136-0008-0 136-0009-3 136-0010-2 136-0011-5 136-0012-8 Female Male Female Male Female Male Female Male Female Male Female Male 12.3 14.8 17.9 35.3 41.8 51.9 7.3 8.7 11g 17g 29g YES The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.

LF Series●Miniature Waterproof Shielded Connectors ■Jacks ØA ØB C ØD (Cable dia.) Part number CL No. Contact Number of contacts ØA ØB C ØD Weight RoHS LF07WBJ-3P LF07WBJ-3S LF07WBJ-6P LF07WBJ-6S LF10WBJ-4P LF10WBJ-4S LF10WBJ-12P LF10WBJ-12S LF13WBJ-20P LF13WBJ-20S LF13WBJ-11P LF13WBJ-11S 136-2003-8 136-2004-0 136-2001-2 136-2002-5 136-2005-3 136-2006-6 136-2007-9 136-2008-1 136-2009-4 136-2010-3 136-2011-6 136-2012-9 Male Female Male Female Male Female Male Female Male Female Male Female 10.3 12.8 15.9 11.5 13.8 16.9 36.3 42.4 52.4 5.0 7.3 8.7 11g 16g 29g 30g 29g 30g YES Unit:mm (Shown one example) The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.

LF Series●Miniature Waterproof Shielded Connectors ■Applicable tools ■Solder termination fixture Contact configuration Shell size LF07 LF10 LF13 Number of contacts Withstanding voltage Current rating Insulation resistance Contact resistance Solder pot inner diameter 1250V AC 1000Mø 15mø 1.15mm 300V AC 0.8mm A+0.05 0Alignment guide B+0.05 ■Panel Cutout ■Contact position arrangement and specifications Note 1: The contact configuration as viewed from the female contact connector mating side. Note 2: The ▼ symbol indicates polarizing key position. Note 3: Withstanding voltages are test voltage values. Part numberDescription CL No. LF series Applicable cable dia. HR10A-TC-02 LF-TC-01 Manual cable clamp crimp Note: Applicable cable dia. is only 5mm for LF series. 150-0041-2 150-0234-6 5 (Note) 7.3 · 8.7 CL No.Part number Applicable connectors 150-0232-0 150-0233-3 150-0235-9 150-0236-1 150-0237-4 150-0238-7 LF07BP-T01 LF07BJ-T01 LF10BP-T01 LF10BJ-T01 LF13BP-T01 LF13BJ-T01 LF07WBP-6S,6P,3S,3P LF07WBJ-6S,6P,3S,3P LF10WBP-4S,4P,12S,12P LF10WBJ-4S,4P,12S,12P LF13WBP-20S,20P,11S,11P LF13WBJ-20S,20P,11S,11P Shell size A B Panel thickness unit (mm) LF07 LF10 LF13 Ø9.05 Ø11.05 Ø14.05 8.1 10.2 13.1 0.5 to 2 0.7 to 2 0.7 to 2 1250V AC 10A 1000Mø 5mø 1.7mm 456 1112 A B 5 6 1 3 D C 32 876 9 10 4 5 1716 131211 14 15 18 19 300V AC 1000Mø 15mø 0.8mm 11 20 AC300V 1000Mø 4mø 0.8mm Unit:mm Ø1.7 5mø Ø0.8 15mø 1000Mø AC300V AC1250V 10A The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.

LF Series●Miniature Waterproof Shielded Connectors ■Termination and Assembly Instructions No. Illustration Operation Solder termination fixture

1 Plug 1

Solder termination fixture Jack Insertion direction Body / insulator assembly Backshell Jack Disassembly Insert the plug into securely held solder termination fixture as shown. Loosen the backshell turning it counter clockwise and remove it from the body/ insulator assembly. Insert the jack into the securely held solder termination fixture as shown. Loosen the backshell turning it counterclockwise. Note

12 Connector Assembly

(1) (2) (3) Backshell Threaded section Tightening collar Threaded section

1 Apply a coating of Loctite 7649

(Manufactured by Henckel Japan, Ltd,) primer to the threaded sections of the backshell and the tightening collar. Completely dry the coated surfaces. Drying time at room temperature is approximately 30 to 70 seconds. Ensure sufficient ventilation of the area at time of drying. Take necessary steps to protect the coated surfaces from contamination. Fixture Part No. Applicable connector LF07BP-T01 LF07WBP-6S,6P,3S,3P LF10BP-T01 LF13BP-T01 LF10WBP-4S,4P,12S,12P LF13WBP-20S,20P,11S,11P Fixture Part No. Applicable connector LF07BJ-T01 LF07WBJ-6S,6P,3S,3P LF10BJ-T01 LF13BJ-T01 LF10WBJ-4S,4P,12S,12P LF13WBJ-20S,20P,11S,11P The connectors are delivered with pre-assembed condition and the disassembly as shown No.1. The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.

Table 2. Stripping Dimensions shielding mesh or cable’s outer jacket. Table 1. Stripping Dimensions The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.

4 Soldering

outer jacket as illustrated. Soldering time: within 5 sec. sufficiently melted on the soldering iron tip. between the conductor and the contact. 1.1 mm min.) over every other wire. tubing should touch the insulator as shown. assure correct assembly of the backshell. Table 4. Wire Dimensions The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.

LF Series●Miniature Waterproof Shielded Connectors No. Soldered joints Cable outer jacket Cable outer jacket 5 to 6mm Cable outer jacket Shielding mesh Wires Copper tape 2 mm max. Copper tape Copper tape Wires Copper tape Overlap of the copper tape Crimping of the Shielding Clamp Solder termination fixture Body / insulator assembly 1±0.5mm Cable outer jacketGround clamp Shielding clamp Shielding mesh Commercially available pliers Overlap of the copper tape E Shielding clamp After completion of the soldering operations carefully remove (holding on the locking collar) the body/insulator assembly from the solder termination fixture. Wrap the folded over shielding mesh with 5 to 6 mm wide copper tape to assure that it will not become loose. Apply the copper tape so that the shielding mesh does not protrude from under it. Insert the “U” shaped shielding clamp over the copper tape as shown on the illustration. It is critical that the overlap of the copper tape is located inside the shielding clamp as shown on the illustration. Using commercially available pliers bend the open ends of the shielding clamp as illustrated, assuring that it stays in place. The dimension of E. between opposing edges of the shielding clamp is necessary to assure correct final crimp. Note Exercise caution not to damage or deform the solder joints. Note After wrapping the copper tape, the tape should overlap itself by 2 mm max. Illustration Operation Note When the end of the copper tape wrapping is positioned at the open side of the ground fitting, the end portion of the copper tape wrapping will no longer be covered by the ground fitting when the ground fitting is crimped. Table 5 Shell size NNNBY NNNBY The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.

LF Series●Miniature Waterproof Shielded Connectors No. Note It is critical that the cable itself will not turn or twist during this operation. Note It is critical that the protrusions are inside the corresponding grooves. Forming cavity Crimping tool 5.3 7.0 Connector Assembly12, BackshellThreaded section Wrench width : D 34, Tightening collar Groove Protrusion Strain relief collar Seal bushing Tightening collar Threaded section Both sides of the shielding clamp must be placed in the forming cavity of the tool (as shown on the illustration) and crimped over the cable by closing the tool completely.

1 Place the body/insulator assembly in the

applicable solder termination fixture. Slide forward the seal bushing and insert it in the backshell until fully seated. Verify that the Locktite 7649 primer (or equivalent) on the threaded sections of the backshell and tightening collar are dry. Apply the Locktite 271 compound to the tightening collar’s threaded section and attach it to the backshell. Slide forward the strain relief collar and insert it in the backshell, making sure that the opposing protrusions fit inside the corresponding grooves, as shown on the illustration.

2 Coat the thread section of the body/insulator

assembly with Loctite 271 compound (manufactured by Henckel Japan, Ltd.) or equivalent, tightening it with a torque specified in the table 6. Illustration Operation Crimping tool Forming cavity Applicable cable diameter Shielding clamp diameter after crimping HR10A-TC-02 5.3 5mm ––– 7.3mm 8.7mm 5.3mm to 5.5mm ––– 7.9mm to 8.1mm 9.1mm to 9.3mm 7.0 LF-TC-01 7.9 9.1 Shell size Tightening torque Wrench width LF07 LF10 10mm1N·m~1.5N·m 1N·m~1.5N·m 13mm LF13 1.5N·m~2N·m 16mm Table 6 Fixture Part No. Applicable connector Fixture Part No. Applicable connector LF07BP-T01 LF10BP-T01 LF13BP-T01 LF07WBP-6S,6P,3S,3P LF10WBP-4S,4P,12S,12P LF13WBP-20S,20P,11S,11P LF07BJ-T01 LF10BJ-T01 LF13BJ-T01 LF07WBJ-6S,6P,3S,3P LF10WBJ-4S,4P,12S,12P LF13WBJ-20S,20P,11S,11P For plug assembly For jack assembly The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.

LF Series●Miniature Waterproof Shielded Connectors No. 6 66 Remove the connector from the solder termination fixture, holding it by the locking collar. Do not pull on the cable. Tightening collar Illustration Operation Shell size Tightening torqueWrench width LF07 LF10 LF13 10mm0.8N·m~1N·m 0.7N·m~1N·m 1 N·m~1.5 N·m 13mm 16mm Wrench width 1. To maintain the water/dust protection performance and the cable clamp force, use a cable that is within the range of applicable diameter. 2. Consult HRS representative when using different cables. ConductorInsulatorShieldJacket ■Cable Specifications (Reference) No. of contact 3 pos. 20 pos. Soft copper wire Ø0.16 7 /Ø0.16 mm dia. AWG #26 0.14 Ø0.48 Ø0.9 (Standard) 0.21 Soft copper wire 80% Ø5.1 Ø8.7±0.2 Material Size (mm) Construction Size (AWG) Sectional area Diameter (mm) Diameter (mm) Thickness (mm) Material Density Diameter (mm) Diameter (mm) Soft copper wire Ø0.18 20 /Ø0.18 mm dia. AWG #20 Ø0.98 Ø1.5 (Standard) 0.26 Soft copper wire 85% Ø3.6 Ø5±0.2 4 pos. 11 pos. Soft copper wire Ø0.16 7 /Ø0.16 mm dia. AWG #26 0.14 Ø0.48 Ø0.95 (Standard) 0.235 6 pos. Soft copper wire Ø0.16 7 /Ø0.16 mm dia. AWG #26 Ø0.48 Ø0.88 (Standard) 0.2 Soft copper wire 85% Ø3.4 Ø5±0.2 12 pos. Soft copper wire Ø0.16 7 /Ø0.16 mm dia. AWG #26 0.14 Ø0.48 Ø0.9 (Standard) 0.21 Soft copper wire 80% Ø4.2 Ø7.3±0.2 Soft copper wire Ø0.26 20 /Ø0.26 mm dia. AWG #16 1.25 Ø1.5 Ø2.1 (Standard) 0.3 Soft copper wire 80% Ø5.5 Ø7.3±0.2 Soft copper wire Ø0.26 26 /Ø0.26 mm dia. AWG #16 1.25 Ø1.5 Ø2.1 (Standard) 0.3 80% Ø6.7 Ø8.7±0.2 Soft copper wire The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.