- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 5
Technical content
LDT2400 Series are high power multipurpose digital power supplies with three phase input voltage 400 – 500 VAC, delivering 2400 W of output power, covering output voltages from 24 to 170 V (model dependent). Their compact size, high efficiency and excellent reliability together with easy installation make them fit demanding applications where compactness and high power are needed. LDT2400 Series are Class I isolation devices suitable for SELV and PELV circuitry (up to 48 VDC models) and are designed to be mounted on DIN rail and installed inside a protective enclosure. 3 phase AC input: 400 – 500 VAC Overload 150% (3600 W peak) Active PFC for optimal efficiency Active input surge suppressor for improved reliability CPU control allows flexibility and multiple programmable features Battery charger function included Thermally regulated fan optimal cooling in harsh operating conditions Wide output voltages range Two phase operation possible with power derating Automation Process Control Communication Instrumentation Equipment
2 LDT2400 Series
tech.support@psbel.com LDT2400-24 400 - 500 VAC / 520 - 725 VDC 3 24 VDC 100 A LDT2400-48 400 - 500 VAC / 520 - 725 VDC 3 48 VDC 50 A LDT2400-72 400 - 500 VAC / 520 - 725 VDC 3 72 VDC 33 A LDT2400-170 400 - 500 VAC / 520 - 725 VDC 3 170 VDC 14 A Technical parameters are typical, measured in laboratory environment at 25°C and 400 VAC / 50 Hz, at nominal values, after minimum 5 minutes of operation. Input AC Voltage Range1 3 phase (UL certified) Operating 400 – 500 VAC 340 – 550 VAC Input DC Voltage Range 520 – 725 VDC Input Frequency 47 - 63 Hz Input AC Current Vin = 400 VAC 4.5 A Vin = 500 VAC 3.5 A Input DC Current Vin = 520 VDC 5.2 A Vin = 725 VDC 3.8 A Power Factor Correction Active > 0.9 Inrush Peak Current Active Inrush current limiter ≤ 10 A Touch (Leakage) Current ≤ 0.6 mA Internal Protection Fuse None, external fuse must be provided Recommended External Protection It is strongly recommended to provide external surge arresters (SPD) according to local regulations Fuse 3x AT 10 A or 3x MCB 10 A C curve 1 In case of 2 phase operation, reduce the output load to 50% of the nominal value. Output Power 2400 W Rated Voltage (Adjustable Voltage Range) LDT2400-24 LDT2400-48 LDT2400-72 LDT2400-170 24 VDC (11.9 - 29 VDC)
48 VDC (23 - 56 VDC)
72 VDC (50 – 87 VDC)
170 VDC (85 – 175 VDC)
Overload Limit (Constant Current Mode) LDT2400-24 LDT2400-48 LDT2400-72 LDT2400-170
150 A / 5 s
75 A / 5 s
50 A / 5 s
21 A / 5 s
Overload Limit (Hiccup Mode) (max. 5s) LDT2400-24 LDT2400-48 LDT2400-72 LDT2400-170 150 A 75 A 50 A 21 A Load Regulation with Remote Sense active and at Vout nom ≤ 1% Ripple & Noise2 ≤ 400 mVpp
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection BCD.00760_AB Hold up Time ≥ 10 ms Output Protections Thermal protection Output overvoltage Output Over Voltage Protection LDT2400-24 LDT2400-48 LDT2400-72 LDT2400-170 ≥ 33 VDC ≥ 68 VDC ≥ 100 VDC ≥ 200 VDC Parallel Connection Possible for power or redundancy (includes internal ORing circuit) Efficiency LDT2400-24 / LDT2400-48 LDT2400-72 LDT2400-170 > 92% > 93% > 92% Dissipated Power LDT2400-24 / LDT2400-48 LDT2400-72 LDT2400-170 < 200 W < 180 W < 200 W 2 Ripple and Noise are measured with 20 MHz bandwidth, probe terminated with a 0.1μF MKP parallel capacitor. 3 Pay attention, set the current limitation mode jumper on C.C. mode when connecting more units in parallel. NOTE: Power rating, losses, efficiency, ripple, thermal behaviour and start-up may change outside of the nominal rated input range. Contact factory for details. Status Signals DC OK / CHARGE - green LED ALARM - red LED Dry contact (SPDT, 24 VDC / 1 A) Alphanumeric LCD display User Interface LCD with 4 keys 0 – 10 V voltage and 4 - 20 mA current output for output current 0 - 100% IN Auxiliary 12 V / 100 mA isolated power supply Load voltage sense Optoisolated remote shut down input USB communication interface via communication module (COMM-BOX) Optional: remote temperature sensor for battery charging (WNTC-2MT) Operating Modes Overboost: allows 150% output power for 5 sec, then off for 10 sec Constant current: adjustable 10 - 100% load Operating Temperature4 UL certified up to 50°C (Start-up type tested: - 40°C)5 - 40 to + 70°C Storage Temperature - 40 to + 80°C Derating Automatic power derating (1200 W) for 2 phase operation - 60 W/°C over 50°C Humidity Non-condensing 5 - 95% RH Life time Expectancy At 25°C ambient full Load 458253 h (52.3 years) Overvoltage Category Pollution Degree III (EN50178) 2 (IEC60664-1) Protection Class Class I Isolation Voltage Input to Output Input to Ground Output to Ground 4.2 kVDC 2.2 kVDC 0.75 kVDC Standards & Approvals UL508 (certified) EN60950 (reference) EN50178 (reference)
4 LDT2400 Series
4 For temperature < - 20°C the LCD is not operating, but the unit will operate correctly
5 Possible at nominal voltage with load derating.
1 Display
2 Control Keys
3 Output Connector
4 Auxiliary Connector
5 Input Connector
6 DIN rail fixing Clamp
7 Communication Interface
8 Status LEDs
9 Buzzer (Internal)
Figure 1. Detail of Auxiliary Connector (4)
Figure 2. Mechanical Drawing equipment used in hazardous environments, or nuclear control systems. date manufactured. Specifications are subject to change without notice.