LDI8119XXEN DIOTEC | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 5

Technical content

Features

Low Dropout Voltage (LDO): 104 mV at 100 mA output current On/Off function (EN) Low power consumption Fixed voltage: Thermal Overload Protection Compliant to RoHS (w/o exemp.), REACH, Conflict Minerals 1) Besonderheiten Niedriger Spannungsabfall (LDO): 104 mV bei 100 mA Ausgangsstom Ein/Aus-Funktion (EN) Energieeffizient Festspannungswerte: Thermische Überlastsicherung Konform zu RoHS (ohne Ausn.), REACH, Konfliktmineralien 1) Mechanical Data 1) Mechanische Daten 1) Taped and reeled 3000 / 7“ Gegurtet auf Rolle Weight approx. 0.039 g Gewicht ca. Case material UL 94V-0 Gehäusematerial Solder & assembly conditions 260°C/4s Löt- und Einbaubedingungen MSL = 3 Maximum ratings 1) Grenzwerte 2) Input voltage Eingangsspannung VIN 18.0 V Output current Ausgangsstrom IOUT 500 mA Power dissipation Verlustleistung Ptot 400 mW 2) Junction temperature Sperrschichttemperatur Tj -40 ... +125°C Storage temperature Lagerungstemperatur TS -40 ... +150°C Typical thermal resistance junction to case Typischer Wärmewiderstand Sperrschicht – Gehäuse RthC 250 K/W 3)

1 Please note the detailed information on our website or at the beginning of the data book

Bitte beachten Sie die detaillierten Hinweise auf unserer Internetseite bzw. am Anfang des Datenbuches

1 TA = 25°C, unless otherwise specified – TA = 25°C, wenn nicht anders angegeben

2 Mounted on P.C. board with 3 mm2 copper pad at each terminal Montage auf Leiterplatte mit 3 mm2 Kupferbelag (Lötpad) an jedem Anschluss © Diotec Semiconductor AG http://www.diotec.com/ 1 VIN VO UT GND EN NC Pb ELV W EEE RoHS Halogen FREE

Characteristics 1 ) Kennwerte 1 ) LDI8119xxEN Min. Typ. Max. Output voltage accuracy – Genauigkeit der Ausgangsspannung IOUT = 30 mΑ, VIN = VOUT + 1.0V LDI8119-2.5EN LDI8119-3.3EN LDI8119-05EN VOUT 2.48 V 3.27 V 4.95 V 2.5 V 3.3 V 5.0 V 2.53 V 3.33 V 5.05 V Output current – Ausgangsstrom VIN = VOUT + 1 V IOUT - 500 mA - Input voltage – Eingangsspannung VIN 1.8 V - 18.0V Line regulation – Betriebsspannungsdurchgriff IOUT = 30 mΑ, VOUT + 1.0V ≤ VIN ≤ 18 V ∆ VOUT / (∆ VIN ∙ VOUT) - 0.05 %/V - Load regulation – Lastregelung VIN = VOUT + 1.0V, 1mA ≤ IOUT ≤ 100 mΑ ∆ VOUT - 7 mV 20 mV Quiescent current – Ruhestrom VIN = VOUT + 1.0V, no load IQ - 1.8 µA 3.6 µA Shutdown Current – Eingangsstrom nach Abschalten VEN < VENL IINL - 0.01 µA 0.2 µA EN input voltage – EN Eingangsspannung Start up – Einschalten Shut down – Ausschalten VENH VENL 1.70 V - - - 0.50 V Dropout voltage – Spannungsabfall 2) IOUT = 100 mΑ LDI8119-2.5EN LDI8119-3.3EN LDI8119-05EN VDO - 220 mV 125 mV 125 mV Short-circuit current – Kurzschluss-Strom VOUT = 0V, ISHORT - 50 mA - Thermal overload protection – Thermische Überlastsicherung IOUT = 20 mA, VIN = VOUT + 1 V TSD - 164 °C - Ripple Rejection – Störspannungsunterdrückung VIN - VOUT= 1 V, IOUT = 10 mΑ Vripple = 1Vpp f = 100 Hz f = 1 kHz f = 10 kHz VRR - 80 dB 65 dB 45 dB Over current protection – Überstromschutz VIN - VOUT= 1 V Ilimit - 780 mA -

1 Tj = 25°C and IOUT= 10mA, VIN = VOUT + 2V, unless otherwise specified

Tj = 25°C und IOUT= 10mA, VIN = VOUT + 2V, wenn nicht anders angegeben 2 VD = VIN1 – (VOUT x 0.98) 2 http://www.diotec.com/ © Diotec Semiconductor AG

Application note Applikationshinweis Typical application circuit for fixed voltage regulator. A 10µF tantalum on the input is suitable for almost all applications. The minimum output capacitance required by LDI8119EN is 10µF, if a tantalum capacitor is used. Larger output capacitance will merely improve the loop stability and transient reponse. Typische Anwendungsschaltung für Festspannungsregler. Ein 10µF Tantal am Eingang ist für fast alle Anwendungen geeignet. Die von LDI8119EN geforderte minimale Ausgangskapazität beträgt 10µF, wenn ein Tantal- Kondensator verwendet wird. Eine größere Ausgangskapazität verbessert lediglich die Einregelstabilität und das Einschwingverhalten. Block Diagram – Blockschaltbild © Diotec Semiconductor AG http://www.diotec.com/ 3 VIN GND EN VOUT NC VIN VOUT VEN 10µF 10µF

Dimensions - Maße [mm] Disclaimer: See data book page 2 or website Haftungssauschluss: Siehe Datenbuch Seite 2 oder Internet 4 http://www.diotec.com/ © Diotec Semiconductor AG Ripple Rejection vs. Frequency (typical) Störspannungsunterdrückung über Frequenz (typisch) PSRR 100 10 102 103 104 107 105 106 [Hz] [dB] I = 10 mAOUT I = 20 mAOUT I = 50 mAOUT I = 100mAOUT V = 4.3 VIN IQ 500 0 2 [V] [µA] 100 200 300 400 Max. Quiescent Current vs. Input Voltage Max. Ruhestrom über Eingangsspannung V = 3.3 VOUT 4 6 8 1210VÍN

The information presented in our data sheets and other docu - ments is to the best of our knowledge true and accurate. It de - scribes the type of component or application and shall not be considered as assured characteristics. No warranty or guaran - tee, expressed or implied is made regarding the capacity, deliv - ery, performance or suitability of any product or circuit etc, nei - ther does it convey any license under the patent rights of oth - ers. Diotec reserves the right to make changes without further no - tice. However, regular updating of all product information is provided on our website 1). All Diotec products are sold and shipped subject to our “Standard Terms and Conditions of Busi - ness” 2). The reproduction of all documents is prohibited with - out the expressed written permission of Diotec Semiconductor AG's Managing Board. Disclaimer 1. All products described or contained are designed and intend - ed for use in standard applications, so called commercial/indus - trial grade, requiring an ordinary level of reliability. 2. Some products are available with the special grades “AEC- Q101 compliant” respectively “AEC-Q101 qualified”. These are automotive standards 3). 3. Customers using these parts in applications requiring a spe - cial or specific grade of quality or reliability, such as (but not limited to) life supporting devices or systems, where failure or malfunction of the product may directly affect human life or health, are obliged to validate whether the use in such cases is appropriate. Diotec does not assume any liability arising out of such applica - tions or uses of its products. Usage in all such cases is on the own and sole risk of the customer. 4. Although Diotec continuously enhances the quality and relia - bility of its products, customers must incorporate sufficient safe- ty measures in their designs, such as redundancy, fire contain - ment, and anti-failure, so that personal injury, fire or environ - mental damage can be prevented. Diotec excludes explicitly ev - ery implied warranty or liability regarding the fitness of the products to any other than standard applications. 5. All information described or contained herein are subject to change without notice. Please contact Diotec to obtain the lat - est information before incorporating Diotec products into any design. 6. All information described and contained herein are intended only to enable the buyer to order Diotec's products. The infor - mation must not be used for any other purpose. 7. In the event that any product described or contained herein falls under the category of strategic products controlled by the German Federal Office of Economics and Export Control, this product must not be exported without obtaining an export li - cense from the German Federal Ministry for Economic Affairs and Climate Action in accordance with the valid laws. Alle Rechte vorbehalten Die Angaben in unseren Datenblättern und sonstigen Dokumen- ten sind nach bestem Wissen und Gewissen gemacht. Sie die - nen jedoch allein der Beschreibung und sind nicht als zugesagte Eigenschaften im Rechts-Sinne zu verstehen. Es wird keine Ge - währ bezüglich Liefermöglichkeit, Ausführung oder Einsatzmög - lichkeit der Bauelemente übernommen, noch dass die angege - benen Bauelemente, Baugruppen, Schaltungen etc. frei von Schutzrechten sind. Wir behalten uns Änderungen der aufgeführten Daten ohne vor- herige Ankündigung vor. Alle Änderungen werden jedoch regel - mäßig auf unserer Internet-Seite veröffentlicht 1). Verkauf und Lieferung von Diotec-Produkten erfolgt gemäß unseren “Allge - meinen Geschäftsbedingungen” 2). Die Vervielfältigung aller Do- kumente ist nur mit schriftlicher Genehmigung des Vorstandes der Diotec Semiconductor AG gestattet. Haftungsausschluss 1. Alle beschriebenen oder enthaltenen Produkte sind für den Gebrauch in Standardanwendungen mit einem gewöhnlichen Zuverlässigkeitsniveau entworfen und bestimmt, bekannt als kommerziell/industrielle Anwendungen. 2. Einige Produkte sind mit den speziellen Qualifikationen „AEC- Q101 konform“ oder „AEC-Q101 qualifiziert“ erhältlich. Dies sind Automotive-Standards 3). 3. Falls diese Produkte in Anwendungen verwendet werden sol - len, die einen besonderen Grad der Qualität oder Zuverlässig - keit erfordern, z. B. (aber nicht begrenzt auf) lebenserhaltende Geräte oder Systeme, bei denen durch Ausfall oder eine Stö - rung des Produktes menschliches Leben oder Gesundheit direkt beeinflusst werden kann, ist der Anwender verpflichtet sicherzu- stellen, dass der beabsichtigte Gebrauch des vorgesehenen Pro- duktes unbedenklich ist. Diotec übernimmt keine Haftung die sich aus solchen Anwen - dungen oder der Verwendung der Produkte ergibt. Der Ge - brauch für alle solche Anwendungen erfolgt auf eigenes und ausschließliches Risiko des Anwenders. 4. Obwohl Diotec die Qualität und die Zuverlässigkeit seiner Produkte beständig erhöht, müssen Kunden ausreichende Si - cherheitsvorkehrungen in ihren Designs vornehmen – wie Red - undanz, Feuereindämmung und Ausfallschutz – damit Perso - nenschäden, Feuer oder Umweltschädigung verhindert werden können. Diotec schließt ausdrücklich jede implizierte Garantie oder Verbindlichkeit aus, welche die Eignung der Produkte zu ir- gendwelchen anderen als Standardanwendungen betrifft. 5. Alle Informationen, die hier beschrieben oder enthalten sind, können jederzeit ohne jede Benachrichtigung geändert werden. Vor Einsatz eines Diotec Produktes in irgendeiner Anwendung sind bei Diotec die neuesten Informationen einzuholen. 6. Alle Informationen, die hier beschrieben oder enthalten sind, sollen dem Kunden nur ermöglichen, Diotec Produkte zu bestel - len. Die Informationen dürfen zu keinem anderen Zweck ver - wendet werden. 7. Sollte ein hier beschriebenes oder enthaltenes Produkt unter Beschränkungen fallen, die durch das deutsche Bundesamt für Wirtschaft und Ausfuhrkontrolle geregelt werden, darf dieses Produkt in Übereinstimmung mit den gültigen Gesetzen nicht ohne Exportgenehmigung vom deutschen Bundesministerium für Wirtschaft und Klimaschutz exportiert werden. 1 Refer to http://diotec.com/ “Products/Product Changes” respectively “News/Datasheets” Siehe http://diotec.com/ „Produkte/Produktänderungen“ bzw. „News/Datenblätter“ 2 Refer data book or http://diotec.com/ “Company” – Siehe Datenbuch oder http://diotec.com/ „Unternehmen“ 3 Refer to http://diotec.com/ “Products/Information/Qualification/Commercial Grade and AEC-Q101” Siehe http://diotec.com/ „Produkte/Informationen/Qualifizierung/Standard und AEC-Q101“ © Diotec Semiconductor AG http://diotec.com/ Disclaimer